Delta Electronics

Delta VFD45AMH43ANSAA Frequency Converter Variable Speed AC Motor Drive

SKU VFD45AMH43ANSAA

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Delta Electronics

  • Product No.: VFD45AMH43ANSAA

  • Country of origin:United States

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 8000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed for precise speed and torque control of three-phase asynchronous and synchronous AC motors, the Delta VFD45AMH43ANSAA frequency converter delivers high-performance motor control across demanding industrial environments. This variable speed AC motor drive is engineered to support dual rating configurations, allowing operations under both heavy-duty and normal-duty classifications depending on the mechanical torque and load dynamics of the system.

Housed in a Frame F enclosure, this drive regulates electrical energy efficiency while providing robust system safety. It integrates seamlessly with plant control networks and is built to optimize energy consumption in heavy-machinery installations, water-handling infrastructure, and automated process lines.

Features

  • Dual-rating operational profiles to match specific load characteristics (Heavy Duty or Normal Duty).
  • Wide operating voltage tolerance to protect against utility grid fluctuations.
  • Adjustable carrier frequency range to optimize noise levels and motor performance.
  • Optional EMC filtering configuration for enhanced electromagnetic compatibility.
  • Compact Frame F footprint designed for efficient panel space utilization.

Applications

  • Industrial conveyor systems and material handling.
  • Centrifugal pumps, industrial fans, and ventilation systems.
  • Air compressors and positive displacement blowers.
  • Extruders, mixers, and heavy machinery in manufacturing.

Technical Specifications

Manufacturer Delta Electronics
Part Number / Model VFD45AMH43ANSAA
Frame Size F
Applicable Motor Output (kW) 22 kW
Applicable Motor Output (HP) 30 HP
Heavy Duty Rated Capacity 34.3 kVA
Heavy Duty Rated Output Current 45.0 A
Normal Duty Rated Capacity 37.3 kVA
Normal Duty Rated Output Current 49.0 A
Carrier Frequency 2 to 15 kHz (Factory setting: 4 kHz)
Rated Input Current (Heavy Duty) 49.5 A
Rated Input Current (Normal Duty) 53.9 A
Rated Input Voltage / Frequency 3-phase AC 380V to 480V (-15% to +10%), 50/60 Hz
Operating Voltage Range 323 to 528 Vac
Frequency Tolerance 47 to 63 Hz
Cooling Method Natural cooling
EMC Filter Optional
Ingress Protection Rating IP20
Shipping Weight 8 kg

Installation Guidelines

  • Mounting: Install the drive vertically on a flat, flame-resistant surface to ensure optimal natural convection cooling.
  • Clearance: Maintain specified minimum clearance distances above, below, and to the sides of the Frame F enclosure to prevent thermal recirculation.
  • Grounding: Ensure a secure and direct low-impedance ground connection to the main industrial ground bus to reduce electrical noise and maximize safety.
  • Wiring: Route power input cabling, motor output cabling, and low-voltage control wiring in separate, dedicated conduits to avoid electromagnetic interference.

FAQ

What is the dual rating of the Delta VFD45AMH43ANSAA?

This frequency converter supports both Heavy Duty (22 kW / 30 HP with a rated output current of 45.0 A) and Normal Duty (rated output current of 49.0 A) profiles to match different industrial application requirements.

What is the input voltage range of this AC drive?

The drive accepts a rated input voltage of 3-phase AC 380V to 480V (-15% to +10%) at 50/60 Hz, with a continuous operating tolerance range of 323 to 528 Vac.

What enclosure protection rating and cooling method does this model have?

The Delta VFD45AMH43ANSAA features an IP20 ingress protection rating and utilizes natural cooling for heat dissipation.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.