1 of 1

EL3022 BECKHOFF 2-Channel Analog Input Terminal 4–20 mA Differential

EL3022 BECKHOFF 2-Channel Analog Input Terminal 4–20 mA Differential

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3022

  • Country of origin:Germany

  • Product Type: EtherCAT Terminal

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The EL3022 (EL3022) is a professional-grade 2-channel analog input terminal designed for the EtherCAT I/O system. It is specifically engineered to process 4 to 20 mA current signals using differential input technology. Unlike single-ended modules, the EL3022’s differential inputs provide superior noise rejection and eliminate ground loop interference, making it the ideal B2B solution for high-precision measurements in electrically noisy industrial environments. With a 12-bit resolution and integrated signal filtering, this terminal is a staple for critical process monitoring, including pressure, flow, and level sensing in chemical, energy, and manufacturing sectors.

Hardware Architecture and Differential Advantage

The EL3022 architecture centers on its two independent differential inputs. By measuring the voltage difference between two signal lines rather than referencing a common ground, the module can effectively cancel out common-mode noise that often plagues long cable runs in industrial facilities. It supports a Common-mode voltage ($U_{CM}$) of up to 10 V, providing significant flexibility in various field wiring topologies.

The terminal features a 1 kHz hardware filter and software-activatable FIR/IIR filters to ensure signal stability. Data is converted via a multiplexing process with a default time of 0.625 ms, ensuring a steady stream of high-quality data to the EtherCAT master. The module is housed in a standard 12 mm polycarbonate casing, featuring 500 V electrical isolation to protect the E-bus backplane from field-side surges.

Technical Specifications

Attribute Specification Details
Model EL3022
Brand BECKHOFF
Number of Inputs 2 (Differential)
Signal Range 4 to 20 mA
Resolution 12 bit (16-bit presentation)
Conversion Time 0.625 ms (Default, configurable)
Input Filter Frequency 1 kHz
Common-Mode Voltage Max. 10 V
Measuring Error < ±0.3 % (relative to full scale)
Internal Resistance Typically 85 Ω + diode voltage
Current Consumption (E-bus) Typically 130 mA
Operating Temperature -25 to +60 Celsius
Approvals CE, UL, ATEX (II 3 G Ex nA IIC T4 Gc)

Technical FAQs

Why choose the EL3022 differential input over a single-ended model?

Differential inputs are essential when sensors are located far from the controller or when the sensors and the PLC operate on different ground potentials. The EL3022 ignores the noise that appears on both signal wires equally, ensuring that only the actual sensor data is processed by the 12-bit converter.

Does this terminal require an external power supply?

The logic and communication of the EL3022 are powered via the E-bus. However, the 4–20 mA current loop for the sensors typically requires an external 24 V DC supply, which can be distributed via separate power feed terminals in the EtherCAT segment.

Can I monitor for sensor failure?

Yes. Since the signal uses the "live zero" 4 mA standard, any reading of 0 mA (or significantly below 4 mA) indicates a wire break or sensor malfunction. The EL3022 supports limit value monitoring to automate these diagnostic alerts in the TwinCAT environment.


Engineering & Installation Guide

  • Wiring for Maximum Precision: Use shielded twisted-pair cables for all differential connections. To maximize the noise-rejection capabilities of the EL3022, the shield should be connected to the functional earth (FE) at the terminal side using a low-impedance shield clamp.

  • Filter Configuration: For slow-moving process variables (like temperature or tank levels), activate the FIR filter via the CoE (CanOpen over EtherCAT) settings to achieve a highly smoothed signal. For more dynamic processes, the IIR filter provides a faster response with effective noise suppression.

  • Maintenance and Replacement: The EL3022 features pluggable wiring level (ES series). This allows for the removal of the terminal block without disconnecting individual wires, facilitating rapid servicing and minimizing the risk of wiring errors during module replacement.

Engineering Advantages

The EL3022 is a robust "problem-solver" for analog signal integrity. Its 12-bit resolution provides ample precision for standard industrial applications, while its ATEX certification allows for safe deployment in Zone 2 hazardous areas. Compliance with EN 61000-6-2/4 ensures that the terminal remains operational in environments with heavy electromagnetic interference. For B2B machine builders and system integrators, the EL3022 offers a reliable, globally-certified interface that simplifies the integration of sophisticated analog instrumentation into the EtherCAT ecosystem.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany
Power source
DC Power

Recently Viewed Products

Technical knowledge

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...