1 of 1

FC101P30KT4E20 Danfoss VLT HVAC Basic Drive 30 kW

FC101P30KT4E20 Danfoss VLT HVAC Basic Drive 30 kW

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: FC101P30KT4E20

  • Country of origin:United States

  • Product Type: Vlt HVAC Basic Drive

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The FC101P30KT4E20 (FC101P30K) is a dedicated VLT HVAC Basic Drive engineered for high-capacity motor control in professional ventilation, heating, and cooling systems. Delivering 30.0 kW (40.0 HP) of power, this frequency converter is optimized for driving large-scale centrifugal fans and pumps in commercial infrastructures like shopping malls, airports, and industrial complexes. The FC101P30KT4E20 is designed to maximize energy efficiency, boasting a 97.0% efficiency rating. By replacing traditional dampers or valves with variable speed control, it significantly reduces operational energy costs and mechanical wear. Its IP20/H7 enclosure is built for centralized cabinet installation, providing a compact footprint for high-power applications where thermal management and reliability are paramount.

Technical Configuration

The FC 101 HVAC Basic series features a robust hardware architecture tailored for long-term performance. It includes built-in functions such as the VVC+ (Voltage Vector Control) for superior motor shaft performance and a Sleep Mode to further enhance energy savings during low-load periods. The unit is equipped with a specialized cooling system that utilizes a forced-air heat sink to maintain stability even at 40 deg C ambient temperatures. It supports large-gauge wiring with terminals accommodating up to 50 mm2 (1 AWG) cables, ensuring secure high-current connections. Additionally, the drive integrates an automatic energy optimizer (AEO) and a flying start feature, allowing it to pick up a spinning fan without tripping, which is essential for large-scale HVAC ventilation loops.

Technical Specifications

Attribute Specification Details
Model FC101P30KT4E20
Brand Danfoss
Power Rating 30.0 kW / 40.0 HP
Input Voltage 380 to 480 VAC (3-Phase)
Continuous Current 115.0 A (at 40 deg C)
Intermittent Current 126.5 A (60 seconds)
Efficiency 97.0 % (Typical)
Power Loss 1015 W (Typical)
Protection Rating IP20 / H7 Enclosure
Operating Temp -10 to 50 deg C (with derating)
Net Weight 36.0 kg
Shipping Weight 38.0 kg

Technical FAQs

Does the FC101P30KT4E20 include an integrated harmonic filter?

Yes, the VLT HVAC Basic series includes built-in DC link reactors that significantly reduce harmonic distortion (THDi) in accordance with IEC/EN 61000-3-12 standards, protecting the local power grid and sensitive equipment.

Can this 30 kW drive be used in high-temperature environments?

The drive is rated for full performance at 40 deg C. It can operate up to 50 deg C, but the continuous output current must be derated to 103.5 A to prevent internal thermal overload and ensure component longevity.

Is it possible to use this drive with permanent magnet motors?

The FC 101 series is primarily designed for high-efficiency asynchronous induction motors. While it provides excellent control for these motors, for PM motor applications, verify the specific software release or consider the VLT HVAC Drive FC 102 series.


Engineering & Installation Guide

Thermal Clearance and Cabinet Airflow: Given the 1015 W typical power loss at full load, the FC101P30KT4E20 requires significant airflow. Maintain a minimum of 200 mm clearance above and below the drive for vertical convection. Ensure the cabinet ventilation fans are rated to handle the heat dissipation to keep the ambient temperature within the 40 deg C nominal range.

High-Current Termination: For the 115.0 A continuous load, use high-quality copper conductors. Ensure the terminal screws are tightened to the torque specifications provided in the manual (approx. 4.5 Nm for this frame size) to prevent hotspots caused by high contact resistance, which can lead to terminal block failure.

Motor Cable Length and Shielding: To ensure EMC compliance and protect motor windings from dV/dt voltage peaks, use shielded cables. If the motor cable length exceeds 50 meters, the installation of an output dV/dt filter is recommended to prevent premature insulation breakdown in the 30 kW motor.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Recently Viewed Products

Technical knowledge

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...

Single-Axis Motion Control Setup with CMZ Servo Drives

This tutorial explores the commissioning of a single-axis servo motion system using a CMZ SBD drive, covering hardware setup, axis scaling, homing configuration, and safe motion verification for...

Mitsubishi FX PLC Integration With FR-D700 VFD and HMI Control

This tutorial explains how Mitsubishi FX PLCs integrate with FR-D700 VFDs and HMI panels for forward/reverse motor control. It covers wiring logic, parameter configuration, ladder programming, and...