General Electric

GE Fanuc IC670MDL642 Field Control 125 VDC 16-Point Discrete Input Module

SKU IC670MDL642

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric

  • Product No.: IC670MDL642

  • Country of origin:United States

  • Product Type: Discrete Input Modules

  • Payment: T/T, Western Union

  • Weight: 350g

  • Dimensions: 110 x 85 x 45 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The GE Fanuc IC670MDL642 is a high-density 125 VDC discrete input module designed for signal acquisition within the Field Control distributed I/O architecture. Functioning as a high-voltage field sensor interface, this module converts incoming 125 VDC discrete signals from plant field switches, relays, and field contactors into internal logic-level signals used by the station CPU or master interface unit.

Occupying a single slot position on a compatible Field Control I/O Terminal Block, the module houses 16 input points organized into two isolated groups. It provides a reliable input link between field-level control hardware and central processing equipment in industrial control stations. Internal logic power for module operation is supplied directly via the 6.5 VDC backplane bus generated by the Field Control Bus Interface Unit (BIU).

Features

  • Features 16 discrete input channels arranged into two isolated groups of 8 points each.
  • Interfaces nominal 125 VDC high-voltage field inputs to low-voltage system logic.
  • Compatible with both positive (sinking) and negative (sourcing) field input signal configurations.
  • Draws a maximum logic backplane current of 77 mA at 6.5 VDC.
  • Integrates directly into Field Control I/O Terminal Blocks without disturbing station field wiring.
  • Supports automatic station layout scanning and slot-by-slot system configuration.

Applications

  • Contact status monitoring for high-voltage DC switchgear and circuit breakers.
  • Interfacing utility-level station battery and DC control bus signals to automation controllers.
  • Processing high-voltage limit switch and safety interlock field contacts.
  • System-level discrete signal monitoring in power generation and substation control systems.

Technical Specifications

Parameter Specification
Manufacturer GE Fanuc / Emerson Automation Solutions
Product Series Field Control
Product Type Discrete Input Module
Module Part Number IC670MDL642
Number of Inputs 16 Points (2 groups of 8)
Nominal Voltage 125 VDC
Input Logic Compatibility Positive / Sourcing or Negative / Sinking
Backplane Current Draw 77 mA maximum at 6.5 VDC
Backplane Voltage 6.5 VDC (supplied by BIU)
Mounting Type DIN Rail Mount via Field Control Terminal Block
Operating Temperature 0 to 55 degC
Storage Temperature -40 to 85 degC
Operating Humidity 5% to 95% non-condensing

Connections / Interfaces

Interface / Signal Function
Terminal Block Base Connects field wiring and provides physical mounting to 35mm DIN rail
Station Interconnect Cable Passes backplane logic power (6.5 VDC) and internal data bus signals between I/O base units
Field Wiring Terminals Terminal connections for 125 VDC positive/negative inputs and group power commons

Installation Guidelines

  1. Disconnect all 24 VDC station supply power and high-voltage 125 VDC field circuits prior to installing or removing hardware.
  2. Confirm that the DIN rail (35mm x 7.5mm) is securely panel-mounted and properly connected to the central earth ground point.
  3. Ensure the I/O Terminal Block is latched onto the DIN rail and interconnected with the station Bus Interface Unit (BIU) using the specified interconnect cable.
  4. Verify the mechanical keying on the I/O Terminal Block to prevent placing an incorrect module type in the slot.
  5. Align the module housing over the assigned terminal block slot and press firmly straight down until fully seated.
  6. Tighten the module retaining screws to ensure proper mechanical mounting and electrical connection.
  7. Complete field wiring according to 125 VDC system schematics, keeping high-voltage DC lines separated from low-voltage communications cables.

Configuration Guidelines

  1. Apply 24 VDC system power to the station Bus Interface Unit to initialize backplane power.
  2. Allow the BIU Autoconfiguration routine to scan the station bus, detect the module in its installed slot, and map default I/O references.
  3. If manual assignment is required, connect a Hand-held Programmer (HHP) to the MONITOR port on the BIU.
  4. Access Module Config to assign specific starting bit references in the system input table (%I).
  5. Configure fault reporting parameters (Report Faults: YES/NO) and module default response states (Hold Last State or default to 0) as required by system control logic.
  6. Verify that assigned module memory addresses fall within the defined station network I/O map.

FAQ

What is the main function of the GE Fanuc IC670MDL642 module?

The GE Fanuc IC670MDL642 is a 16-point discrete input module designed for Field Control I/O systems. It converts high-voltage 125 VDC discrete signals from field switches, relays, and contactors into logic-level data for processing by the central system controller.

How much backplane current does the GE Fanuc IC670MDL642 consume?

The GE Fanuc IC670MDL642 draws a maximum backplane current of 77 mA at 6.5 VDC. Logic power for the module is supplied directly from the station Bus Interface Unit across the Field Control backplane bus.

Does the GE Fanuc IC670MDL642 support both positive and negative logic?

The GE Fanuc IC670MDL642 supports both positive (sinking) and negative (sourcing) field input wiring configurations across its 16 points, which are organized into two isolated groups of 8.

How is the GE Fanuc IC670MDL642 configured within a Field Control station?

The GE Fanuc IC670MDL642 can be autoconfigured at power-up by the station Bus Interface Unit, which detects the module and assigns default I/O memory references. Manual memory mapping, fault reporting, and hold-last-state settings can be configured using a Hand-held Programmer.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Fanuc IC670MDL642 Field Control 125 VDC 16-Point Discrete Input Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 18 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

Technical knowledge

1746-A7 Chassis Replacement Checks: Slots, Power and Interconnects

An engineering checklist for replacing an Allen-Bradley 1746-A7: verify chassis series, backplane loading, slot plan, interconnect cables, mounting, grounding and receiving condition.

IC200MDL650 Replacement Checks: Logic Polarity, Filters, and Commons

A field replacement guide for GE Fanuc IC200MDL650 covering revision-dependent negative logic, four common groups, 24 VDC thresholds, input filtering, carrier checks and commissioning records.

IC697CPX935 Replacement Checks: Memory, Ports, and Rack Power

A field-focused IC697CPX935 replacement guide covering fast memory, firmware-dependent serial behavior, rack power, cooling, I/O architecture and backup records.

IC693DSM324 Replacement Checks: FSSB, Firmware and Follower Control

A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.

HIMA F3430 Replacement Checks: Contact Ratings and Safety Limits

A field-focused HIMA F3430 replacement guide covering relay contact ratings, DC load derating, fusing, F3330/F3331 differences, safety restrictions and commissioning records.

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits

A field-focused IC697PWR710 replacement guide covering 5 V load calculations, dual-rack limits, extension cables, input checks, protection behavior and hardware revision risks.