The TMR DIN rail assembly board functions as a high-reliability hardware interface designed for the General Electric Mark VIe control platform. The IS230TAISH2C facilitates critical signal routing and field wiring integration, enabling structured connection pathways for sensors and actuators in mission-critical applications. By supporting Triple Modular Redundancy (TMR) architectures, this board provides cross-channel signal availability and hardware fault tolerance across dual or triple controller infrastructures linked via the high-speed IONet communication protocol. This continuous synchronization and majority voting capability ensure absolute data integrity for continuous process operations in demanding heavy industries like thermal power stations, petrochemical plants, and oil refining infrastructure.

Features

  • Equipped with an onboard heavy-duty terminal block providing up to forty-eight (48) individual field wiring terminals.
  • Supports scalable redundant system architectures, interfacing seamlessly with simplex, dual, or fanned TMR controller layouts.
  • Native alignment with high-speed IONet communication channels to handle precise controller state synchronization and voting tracking.
  • Designed for standard 35 mm DIN-rail mounting configurations to optimize high-density cabinet layouts and installation workflows.
  • Certified under strict industrial safety listings for dependable deployment in hazardous and non-hazardous operating zones.

Applications

  • Steam and Gas Turbine Protection Systems
  • Triple Modular Redundant (TMR) Control Architectures
  • Emergency Interlocking and Safety Shutdown Panels
  • Power Generation Plant Automation Infrastructure
  • Hazardous Area Field Instrument Distribution Links

Technical Specifications

Parameter Configuration and Rating Value
Manufacturer GE (General Electric)
Model IS230TAISH2C
Series Mark VIe Control System
Product Type TMR DIN Rail Assembly Board
Mounting Format Standard 35 mm DIN-Rail
Terminal Capacity Forty-eight (48) screw termination points
Country of Origin United States (USA)
Availability In Stock / Factory New
Standard Repair Turnaround 3 to 5 business days

Installation Guidelines

  • DIN Rail Mounting: Mount the assembly board horizontally or vertically on a standard 35 mm symmetric DIN rail. Ensure the locking tabs are completely engaged with the rail structure to resist cabinet vibrations.
  • Field Conductor Wiring: Strip field device and sensor signaling cables to the standard specified insulation length. Secure individual leads into the 48-point terminal block using calibrated screwdrivers to maintain accurate electrical contact tension.
  • Shielding and Data Integrity: Route incoming low-voltage sensor lines through dedicated grounded wire trays. Connect cable drain wires directly to the designated cabinet enclosure earth bar to suppress industrial electromagnetic interference (EMI).

Compliance and Certifications

  • UL E207685 Certification (Non-Hazardous Environments)
  • Class I, Division 2, Groups A, B, C, D
  • Class I, Zone 2, Group IIC

What is the maximum field connection capacity of this terminal assembly?

The board features a high-density terminal block configuration that accommodates up to forty-eight (48) distinct field device and sensor wire connections.

Why do multiple controllers synchronize state parameters across this hardware system?

Synchronization is required to maintain consistent and coordinated voting logic across the redundant network, protecting data integrity and reducing unexpected operational downtime.

What primary network handles the continuous data exchange between redundant nodes?

Redundant controllers utilize high-speed IONet channels to exchange calculated variables, internal timers, counter parameters, and real-time logic signals continuously.

Is this assembly board certified for installation in hazardous industrial zones?

Yes, it holds safety certifications for deployment in Class I, Division 2, Groups A, B, C, D and Class I, Zone 2, Group IIC environments.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black Green Silver
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...

Single-Axis Motion Control Setup with CMZ Servo Drives

This tutorial explores the commissioning of a single-axis servo motion system using a CMZ SBD drive, covering hardware setup, axis scaling, homing configuration, and safe motion verification for...

Mitsubishi FX PLC Integration With FR-D700 VFD and HMI Control

This tutorial explains how Mitsubishi FX PLCs integrate with FR-D700 VFDs and HMI panels for forward/reverse motor control. It covers wiring logic, parameter configuration, ladder programming, and...