General Electric

General Electric DS200CTBAG1ADD Analog Termination Module

SKU DS200CTBAG1ADD

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric

  • Product No.: DS200CTBAG1ADD

  • Country of origin:United States

  • Product Type: Analog Termination Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 220g

  • Dimensions: 16.3 x 10.2 x 3.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The General Electric DS200CTBAG1ADD is an Analog Termination Module designed specifically for the GE Mark V Speedtronic turbine control system architecture. Operating primarily within the R5 core, this terminal board acts as a centralized node for routing, terminating, and managing critical analog signals within gas and steam turbine management loops. It facilitates seamless signal interchange between field instrumentation and the primary control processors, ensuring stable data acquisition and robust electrical noise immunity in high-vibration industrial environments.

Engineering features of the DS200CTBAG1ADD include dedicated onboard voltage-limiting hardware supported by precision red-coated protective diodes and specialized conductive ground mounting holes for optimal electromagnetic compatibility (EMC). The module incorporates an extensive array of interface ports, including dual COREBUS connections (JAI and JAJ) for high-speed intra-system communication, multiple vertical pin cable and header connectors for internal harness integration, and a diagnostic serial interface port.

Features

  • Engineered specifically for the GE Mark V Speedtronic gas and steam turbine control ecosystem
  • Optimized for installation within the R5 core rack architecture
  • Equipped with dual COREBUS interface connectors (JAI and JAJ) for reliable internal data transmission
  • Integrated voltage-limiting hardware utilizing red-coated diodes for transient suppression
  • Multiple vertical pin cable and header connectors for secure internal harness termination
  • Onboard 9-pin male serial connector for diagnostics, configuration, and maintenance access

Applications

  • Analog sensor signal termination and routing in Mark V turbine control panels
  • Data acquisition and processing for gas and steam turbine regulation loops
  • Redundant signal interfacing within Simplex and TMR (Triple Modular Redundant) turbine architectures
  • Legacy system hardware restoration, expansion, and direct drop-in replacement

Technical Specifications

Parameter Specification
Brand General Electric (GE)
Product Line Mark V Speedtronic / EX2100 compatible
Module Type Analog Termination Module (PCB Board Assembly)
Core Location R5 Core
Communication Interfaces 2 x COREBUS connectors (JAI, JAJ), 1 x 9-pin male serial connector
Internal Connectors 5 x vertical pin cable connectors, 2 x vertical pin header connectors
Protection & Regulation Onboard voltage-limiting diodes, conductive grounding mounting holes
Country of Origin United States
Net Weight 0.22 kg
Dimensions 16.3 x 10.2 x 3.0 cm

FAQ

What is the primary function of the GE DS200CTBAG1ADD module?

The DS200CTBAG1ADD is an Analog Termination Module utilized in the GE Mark V Speedtronic turbine control system to terminate, route, and condition critical analog signals between field devices and the control processor.

Which control system architecture is this module designed for?

It is engineered specifically for the GE Mark V Speedtronic system architecture, typically operating within the R5 core of gas and steam turbine management panels.

What communication ports are available on the DS200CTBAG1ADD board?

The board features two COREBUS connectors designated as JAI and JAJ for internal system communication, along with a 9-pin male serial connector for service and diagnostics.

How is electrical protection handled on this termination board?

The module includes integrated voltage-limiting hardware featuring red-coated protective diodes and specialized conductive mounting holes designed to maintain proper system grounding and EMC performance.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.