General Electric

General Electric IS200TTSAG1A Mark VI Trip Solenoid Interface Board

SKU IS200TTSAG1A

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric

  • Product No.: IS200TTSAG1A

  • Country of origin:United States

  • Product Type: Turbine Emergency Trip Board

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 907g

  • Dimensions: 8.26 cm x 4.18 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The IS200TTSAG1A functions as a high-reliability trip solenoid interface board manufactured by General Electric as an integral element of the Mark VI Speedtronic gas turbine control platform. Operating on a stable QNX foundation, this card acts as a specialized protective mediator that bridges low-power central control module logic commands with high-power electromechanical emergency trip solenoids. The IS200TTSAG1A monitors field status loops over 12 independent channels, executing split-second signal processing to immediately activate the trip solenoid and interrupt equipment power loops during detected critical system faults or turbine overspeed emergencies.

Features

  • Multi-Channel Safety Topology: Provides 12 dedicated communication channels optimized to coordinate safety-interlocking trip inputs and feedback signals.
  • Electrical Noise Isolation: Incorporates robust electrical isolation circuitry to secure the low-voltage control system processing path from high-power field surges, inductive noise, and voltage spikes.
  • Precision Current Control: Regulates a consistent analog output current range spanning 0-20 mA to maintain accurate actuator alignment thresholds.
  • Onboard Diagnostic Monitoring: Equipped with visual indicators and functional circuit validation routines to provide prompt status feedback, simplifying system fault isolation.

Applications

  • Mark VI Speedtronic emergency gas and steam turbine trip control loops
  • Critical equipment safety interlocking in power generation and oil facilities
  • High-speed industrial emergency shutdown (ESD) management systems

Technical Specifications

Item Description / Value
Manufacturer General Electric
Series Mark VI
Part Number IS200TTSAG1A
Product Type Trip Solenoid Interface Board
Number of Channels 12
Operating System QNX
Analog Output Current 0-20 mA
Common Mode Voltage Range +5 V dc
Maximum Lead Resistance 15 ohm
Operating Temperature -30 to 65 degC
Height 8.26 cm
Width 4.18 cm
Weight 2 lbs
Country of Origin United States

Installation Guidelines

  • Loop Resistance Constraints: Limit the connected field instrumentation wire networks to a maximum lead resistance of 15 ohm to prevent signal attenuation and circuit errors.
  • Common Mode Verification: Ensure external reference loops stay aligned with the required +5 V dc common mode voltage parameters before powering up the equipment.
  • Enclosure Grounding: Secure the board framework firmly within its dedicated slot frame using standard conductive mounting practices to establish common grounding baselines.

FAQ

What is the primary operational function of the device within a turbine system?

The device acts as a high-speed electrical mediator between the central control system and the trip solenoid, activating the solenoid to instantly cut power to equipment during an emergency shutdown.

What is the maximum allowable loop resistance for field connections?

To ensure correct signal transmission and safety loop integrity, the external wiring network must not exceed a maximum lead resistance of 15 ohm.

Which operating system framework does this hardware module utilize?

This specialized safety interface board runs and relies on the real-time QNX operating system platform for its execution timings.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.