Description

The IS200TVIBH2BCC functions as a dedicated terminal vibration board manufactured by GE Industrial Systems under the General Electric production umbrella for the Mark VI Speedtronic control series. This module serves as a critical connection layer within the greater VVIB vibration and position board assembly, enabling direct interface paths for up to fourteen Bently Nevada proximity probes tasked with mechanical shaft vibration monitoring. Engineered to support robust diagnostic applications, the IS200TVIBH2BCC outputs buffered raw signals to facilitate localized parameter collection by portable data gathering hardware without interrupting active machinery protection tracking.

This customizable terminal hardware modification extends its system compatibility beyond traditional steam and gas utility turbine governance loops, featuring validated integration pathways for industrial wind turbine management systems. Outfitted with multiple configurable hardware jumper pairs, the board establishes accurate sensor signal routing and matching impedance baselines across dynamic rotating machinery diagnostics.

Features

  • Multi-Probe Monitoring Interface: Provisions direct termination lanes for up to fourteen external Bently Nevada probes to execute continuous shaft vibration analysis.
  • Dedicated Diagnostic Outlets: Incorporates fourteen standalone BNC connectors designed to isolate and distribute buffered sensor wave vectors directly to portable data logging equipment.
  • High-Density Pluggable Blocks: Hosts two screw-secured terminal blocks supporting 24 I/O connections each, yielding a total of 48 removable field terminal termination points.
  • Highly Customizable Architecture: Populated with sixteen configurable hardware jumper pairs to modify board layouts and factory-specified tracking configurations.
  • Industrial Grade Layer Shielding: Protected by a thin, specialized conformal circuit coating that completely encapsulates board elements against corrosive contamination.

Applications

  • Mark VI Speedtronic heavy-duty gas, steam, and wind turbine shaft vibration monitoring
  • Real-time dynamic machinery diagnostic and predictive maintenance data logging
  • Field proximity probe signal conditioning and terminal block routing

Technical Specifications

Item Description / Value
Original Manufacturer GE Industrial Systems
Product Series Mark VI Speedtronic
Functional Part Number IS200TVIBH2BCC
Functional Acronym TVIB
Functional Description Termination Vibration Board
PCB Coating Conformal Coating
1st Functional Revision B
2nd Functional Revision C
Artwork Revision C
Probe Connections Supported Up to 14 Bently Nevada probes
Buffered Signal Connectors 14 BNC interface ports
Total Terminal Block Connections 48 I/O connection points (24 per block)
Onboard Configurable Jumpers 16 jumpers
Country of Origin USA

Installation Guidelines

  • Terminal Block Fastening: Ensure the two large pluggable terminal blocks are secured onto the base circuit card structure via the four factory-supplied retention screws to maintain physical bridge alignment.
  • Jumper Map Validation: Verify the position and label alignment of the sixteen hardware jumper pairs match the designated system site specifications prior to applying loop excitation power.
  • Signal Shield Isolation: Ground external probe transmission shielding leads through the proper terminal common points to mitigate ambient plant electromagnetic disruptions across the BNC outputs.

FAQ

Which specific product assembly group does this card belong to?

As designated by the H2 series marker in the functional part number, this board belongs to group two within the greater Mark VI Speedtronic series.

Are the two individual C-rated revisions on the board backwards-compatible?

No, because the two C-rated indicators signify completely separate revision types (the second functional revision and the artwork revision), they are not backwards-compatible.

What is the primary function of the fourteen onboard BNC connectors?

The fourteen BNC connectors are used to distribute buffered sensor signals directly to portable data gathering and analyzer units for diagnostic maintenance checks.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
United States
Power source
DC Power

Technical knowledge

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Securing Remote PLC Access Beyond the VPN

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...