General Electric IS200TVIBH2BCC Mark VI Termination Vibration Board
SKU IS200TVIBH2BCC
In stock
No reviews
12-month warranty
Free returns within 30 days
Manufacturer:
General Electric
Product No.:
IS200TVIBH2BCC
Country of origin:United States
Product Type:
Termination Vibration Board
Barcode:
8537101190
Payment:
T/T, Western Union
Weight:
580g
Dimensions:
33cm x 17.7cm x 4cm
Shipping port:
Xiamen
Warranty:
12 months
Description
The IS200TVIBH2BCC functions as a dedicated terminal vibration board manufactured by GE Industrial Systems under the General Electric production umbrella for the Mark VI Speedtronic control series. This module serves as a critical connection layer within the greater VVIB vibration and position board assembly, enabling direct interface paths for up to fourteen Bently Nevada proximity probes tasked with mechanical shaft vibration monitoring. Engineered to support robust diagnostic applications, the IS200TVIBH2BCC outputs buffered raw signals to facilitate localized parameter collection by portable data gathering hardware without interrupting active machinery protection tracking.
This customizable terminal hardware modification extends its system compatibility beyond traditional steam and gas utility turbine governance loops, featuring validated integration pathways for industrial wind turbine management systems. Outfitted with multiple configurable hardware jumper pairs, the board establishes accurate sensor signal routing and matching impedance baselines across dynamic rotating machinery diagnostics.
Features
Multi-Probe Monitoring Interface: Provisions direct termination lanes for up to fourteen external Bently Nevada probes to execute continuous shaft vibration analysis.
Dedicated Diagnostic Outlets: Incorporates fourteen standalone BNC connectors designed to isolate and distribute buffered sensor wave vectors directly to portable data logging equipment.
High-Density Pluggable Blocks: Hosts two screw-secured terminal blocks supporting 24 I/O connections each, yielding a total of 48 removable field terminal termination points.
Highly Customizable Architecture: Populated with sixteen configurable hardware jumper pairs to modify board layouts and factory-specified tracking configurations.
Industrial Grade Layer Shielding: Protected by a thin, specialized conformal circuit coating that completely encapsulates board elements against corrosive contamination.
Applications
Mark VI Speedtronic heavy-duty gas, steam, and wind turbine shaft vibration monitoring
Real-time dynamic machinery diagnostic and predictive maintenance data logging
Field proximity probe signal conditioning and terminal block routing
Technical Specifications
Item
Description / Value
Original Manufacturer
GE Industrial Systems
Product Series
Mark VI Speedtronic
Functional Part Number
IS200TVIBH2BCC
Functional Acronym
TVIB
Functional Description
Termination Vibration Board
PCB Coating
Conformal Coating
1st Functional Revision
B
2nd Functional Revision
C
Artwork Revision
C
Probe Connections Supported
Up to 14 Bently Nevada probes
Buffered Signal Connectors
14 BNC interface ports
Total Terminal Block Connections
48 I/O connection points (24 per block)
Onboard Configurable Jumpers
16 jumpers
Country of Origin
USA
Installation Guidelines
Terminal Block Fastening: Ensure the two large pluggable terminal blocks are secured onto the base circuit card structure via the four factory-supplied retention screws to maintain physical bridge alignment.
Jumper Map Validation: Verify the position and label alignment of the sixteen hardware jumper pairs match the designated system site specifications prior to applying loop excitation power.
Signal Shield Isolation: Ground external probe transmission shielding leads through the proper terminal common points to mitigate ambient plant electromagnetic disruptions across the BNC outputs.
FAQ
Which specific product assembly group does this card belong to?
As designated by the H2 series marker in the functional part number, this board belongs to group two within the greater Mark VI Speedtronic series.
Are the two individual C-rated revisions on the board backwards-compatible?
No, because the two C-rated indicators signify completely separate revision types (the second functional revision and the artwork revision), they are not backwards-compatible.
What is the primary function of the fourteen onboard BNC connectors?
The fourteen BNC connectors are used to distribute buffered sensor signals directly to portable data gathering and analyzer units for diagnostic maintenance checks.
A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...
Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...
Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...
Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.
Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.
A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...
Choosing a selection results in a full page refresh.