Honeywell CC-PAIH02 Series C300 HART Analog Input Module

Only 6 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: CC-PAIH02

  • Country of origin:United States

  • Product Type: Analog Input Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for seamless integration within the Honeywell Experion PKS C300 controller platform, the CC-PAIH02 serves as a high-density, HART-enabled analog input module. This Series 8 I/O module processes critical analog signals from field transmitters while simultaneously facilitating bidirectional HART digital communication. By extracting secondary variables and diagnostic data from smart field devices, the module enables comprehensive asset management and predictive maintenance workflows without requiring additional hardware.

The CC-PAIH02 configuration features 16 single-ended analog input channels designed to interface with 4-20 mA current loops or standard voltage signals. Operating on the Series 8 form factor, it mounts directly to its corresponding Input Output Termination Assembly (IOTA), optimizing cabinet space and simplifying field wiring. This robust industrial design provides reliable signal isolation, high-resolution analog-to-digital conversion, and continuous loop power distribution to standard 2-wire transmitters.

Features

  • HART Protocol Pass-Through: Supports simultaneous transmission of analog process variables and digital HART diagnostics for advanced asset tracking.
  • High-Density Architecture: Incorporates 16 single-ended analog input channels within a single space-saving Series 8 module.
  • Hot-Swappable Design: Allows online module replacement under power without disrupting process operations or active control loops.
  • Advanced Diagnostics: Continuous internal self-tests, open-circuit detection, and channel-level status monitoring.
  • Galvanic Isolation: Protects control system electronics from field-side electrical noise and transient surges.

Applications

  • Oil and Gas refining and petrochemical distribution networks.
  • Continuous process monitoring in chemical manufacturing plants.
  • Power generation plant instrumentation and control loop integration.
  • Water and wastewater treatment facility telemetry monitoring.

Technical Specifications

ManufacturerPart Number / ModelSeriesModule TypeNumber of ChannelsInput RangeDigital CommunicationResolutionMounting AlignmentShipping Weight
Honeywell
CC-PAIH02
Experion C300 Series 8 I/O
HART Analog Input Module
16 Channels (Single-Ended)
4-20 mA / 1-5 VDC
HART Protocol (Version 5, 6, and 7 compatible)
16-Bit Analog-to-Digital Converter (ADC)
Vertical mounting on dedicated Series 8 IOTA
2.0 kg

Installation Guidelines

The CC-PAIH02 must be installed on a compatible Series 8 Input Output Termination Assembly (IOTA). Ensure that the IOTA is properly grounded to the cabinet common ground plane prior to mounting the module. Secure the module onto the IOTA using the integrated fastening screws to guarantee sound electrical contact and mechanical stability. For optimal thermal management, maintain the recommended ventilation clearances within the C300 controller enclosure. Always adhere to standard ESD (Electrostatic Discharge) prevention protocols when handling the module.

Loading product navigation…

Does the CC-PAIH02 module support both active and passive analog loops?

Yes, the CC-PAIH02, when paired with the appropriate Input Output Termination Assembly (IOTA), can support both 2-wire (loop-powered) and 4-wire (externally powered) transmitters.

What is the primary difference between the CC-PAIH02 and older Honeywell analog input modules?

The CC-PAIH02 belongs to the Series 8 form factor designed specifically for C300 controllers, featuring onboard HART digital communication pass-through, enhanced channel density, and simplified IOTA-based wiring compared to legacy Series A I/O.

Can the CC-PAIH02 module be hot-swapped while the C300 controller is online?

Yes, the CC-PAIH02 supports hot-swapping (Online Insertion and Removal). You can replace a faulty module under power without interrupting the operation of other modules or the controller.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...