Description

The INICI03 Infi-Net to Infi-Net Local Transfer Module is a Harmony rack communication interface designed for the Symphony Enterprise Management and Control System. It serves as an intelligent bridge, providing a host computer or Human System Interface (HSI) with direct access to the Control Network (Cnet) or INFI-NET communication system.

The INICI03 is backward-compatible with existing INFI 90 OPEN Strategic Enterprise Management Systems.

The complete interface assembly is a multi-module hardware system comprising three primary components:

  • INNIS01 Network Interface Module: Provides the intelligent front-end connection between the node and the communication network.
  • INICT03 Computer Transfer Module: Serves as the command-driven processing core for data buffering, point tables, and host interactions.
  • IMMPI01 Multifunction Processor Interface Module: Provides the physical hardware interface for RS-232-C serial or SCSI parallel host connections.

Features

  • High-Capacity Data Buffering: Dynamically packs and organizes process information and exception reports for efficient network transmission.
  • Large Point Storage Capacity: The integrated INICT03 module can store up to 30,000 point definitions, depending on the point types.
  • Robust Data Integrity: Transmitted network frames use Cyclic Redundancy Check (CRC) codes and checksum verification.
  • Automatic Power Recovery: Localized startup and shutdown procedures execute automatically following a power failure.
  • Asynchronous Processing: Local data buffering allows the host computer to poll data independently of the real-time Cnet clock.

Applications

  • Symphony Enterprise Management and Control Systems
  • INFI 90 OPEN DCS system integration
  • Central engineering and configuration stations using Composer tools
  • Plant-wide Human System Interface workstations using Conductor NT or Conductor VMS

Technical Specifications

Property Characteristic / Value
Manufacturer ABB / Bailey Hartmann & Braun
Product ID INIIT03
Product Type Hardware
Country of Origin Italy (IT)
Stocked At ITABB004EXPU
Minimum Order Quantity 1 piece
IMMPI01 Power Requirements +5 VDC at 415 mA; 2.08 W typical
INICT03 Memory 512 kbytes ROM; 2 Mbytes RAM
INICT03 Power Requirements +5 VDC at 1.958 A; 9.8 W typical
INICT03 Communication Rates 50 to 19,200 baud through RS-232-C; 4 Mbytes/sec through SCSI
INNIS01 Memory 64 kbytes ROM; 208 kbytes RAM
INNIS01 Power Requirements +5 VDC at 900 mA (4.5 W typical); +15 VDC at 5 mA (0.08 W typical); -15 VDC at 200 mA (3 W typical)
INNIS01 Network Rates 10 Mbaud or 2 Mbaud
System Capacity Up to 62,500 total system nodes; up to 250 nodes per individual loop
Mounting Each module occupies one slot in a standard Module Mounting Unit (MMU)
Ambient Temperature 0 to 70°C (32 to 158°F)
Relative Humidity 5% to 90% up to 55°C (131°F), noncondensing; 5% to 40% above 55°C (131°F), noncondensing
Atmospheric Pressure Sea level to 3 km (1.86 mi)
Air Quality Noncorrosive

Installation Guidelines

  • Electrostatic Protection: The modules contain components sensitive to electrostatic discharge. Personnel must wear a grounded wrist strap connected to the cabinet chassis ground before handling circuitry.
  • Hardware Address Configuration: Before installing modules in the Module Mounting Unit, configure the circuit-board DIP switches for the required node address, loop address, and loop operating mode.
  • Machine Fault Timer: Do not operate the modules with the machine fault timer circuit manually disabled. Doing so may produce unpredictable output sequences and compromise loop safety.
  • Module Insertion: Verify cabinet power-loading limits before installation. Insert each module into its designated card-cage slot and fully tighten both faceplate retaining screws.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

INICI03 ABB Infi-Net To Infi-Net Local Transfer Mod

What is the total node capacity supported by the communication system interface?

The interface can support up to 62,500 system nodes globally, with a capacity of up to 250 nodes per individual loop network.

What host computer interface connections are supported by the device?

The system interfaces with a host computer via either an RS-232-C serial link supporting rates up to 19.2 kilobaud, or a high-speed SCSI parallel port on the faceplate.

What is the acceptable ambient operating temperature range for the device?

The device is specified to operate within an ambient temperature range of 0 degC to 70 degC (32 degF to 158 degF).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Switzerland
Power source
DC Power

Recently Viewed Products

Technical knowledge

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...