The 060L315666 (060L315666) is a heavy-duty KPS 80 series temperature switch designed by Danfoss for demanding industrial and marine applications. Featuring a robust adsorption charge sensing system, this controller operates within a 70 to 120 deg C range, providing reliable thermostat functionality in engine rooms, power plants, and chemical processing facilities. The 060L315666 is engineered to withstand high vibration and harsh environmental conditions, utilizing a 3000 mm armored capillary tube to allow for flexible sensor placement while protecting the internal hydraulic circuit. By employing high-quality SPDT gold-plated contacts, this unit ensures fail-safe switching for both high-power loads and low-voltage PLC signals, significantly enhancing system safety and preventing thermal runaway in critical machinery.

Technical Configuration

The KPS 80 series is distinguished by its mechanical durability and precision adjustment capabilities, specifically configured for industrial endurance:

  • Sensing Element: Utilizes an adsorption charge principle, which offers high resistance to ambient temperature fluctuations and ensures the setpoint remains stable even when the housing is exposed to varying conditions.

  • Armored Capillary: Features a 3000 mm (118 1/8 in) armored capillary tube, providing mechanical protection against abrasion, kinking, and impact in heavy-duty industrial settings.

  • Switching Mechanism: Equipped with an SPDT (Single Pole Double Throw) contact system with gold plating, making it compatible with low-current electronics (1-30 mA) as well as standard AC motor loads up to 440 V.

  • Enclosure and Entry: Housed in a rugged enclosure with a Pg 13.5 metal cable gland and screwed cable entry, ensuring a secure and vibration-proof electrical connection.

  • Differential Control: Features an adjustable differential type, allowing engineers to fine-tune the "cut-in" and "cut-out" points to prevent rapid cycling of connected equipment.

Technical Specifications

Feature Specification
Model 060L315666
Brand Danfoss
Series KPS 80
Temperature Range 70 to 120 deg C
Capillary Length 3000 mm (Armored)
Sensor Connection M 18 x 1.5
Contact Type SPDT Gold
Max Ambient Temp 70 deg C (Short-term 80 deg C for 120 min)
Contact Rating (AC1) 10 A, 440 V
Contact Rating (DC13) 12 W, 220 V
Electrical Entry Pg 13.5 Metal Gland
Net Weight Approx. 1.2 kg
Shipping Weight 2.5 kg

Technical FAQs

What is the advantage of the "Adsorption Charge" in the 060L315666?

The adsorption charge allows the sensor bulb to be placed in environments either warmer or colder than the switch housing without affecting the accuracy of the setpoint. This makes it superior to vapor charge sensors in applications where the ambient temperature near the controller housing varies significantly.

Can I use this temperature control for low-voltage PLC inputs?

Yes. The 060L315666 features gold-plated contacts designed for reliable switching at low voltages (5-30 V) and low currents (1-30 mA). This prevents oxide buildup on the contacts, which is a common cause of signal failure in standard silver contacts used with PLCs.

How do I adjust the temperature differential?

The differential is adjusted via the internal setting disk. By increasing the differential, you increase the gap between the temperature at which the switch activates and the temperature at which it resets, which is essential for protecting motors and compressors from frequent starting and stopping.


Engineering & Installation Guide

  • Capillary Management: When installing the 3000 mm armored capillary, ensure the bend radius never drops below 25 mm. Despite the armoring, sharp bends can cause micro-fractures in the internal tube, leading to a loss of charge and total sensor failure.

  • Mounting and Vibration: The KPS series is highly vibration-resistant; however, for maximum longevity in marine engines or compressors, mount the housing on a vibration-damped surface and use the armored capillary to isolate the switch body from the direct heat and vibration of the medium.

  • Electrical Sealing: Ensure the Pg 13.5 metal cable gland is tightened correctly to maintain the enclosure's integrity. For installations in high-moisture environments, a "drip loop" in the wiring is recommended to prevent water from traveling down the cable and entering the terminal block.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Denmark

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...