BECKHOFF

KS3172 | BECKHOFF | Bus Terminal

SKU KS3172

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: KS3172

  • Country of origin:Germany

  • Product Type: 2-Channel High-Precision Analog Input Bus Terminal

  • Payment: T/T, Western Union

  • Weight: 70g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Beckhoff KS3172 is a high-precision, two-channel differential 0–2 V analog input Bus Terminal. The pluggable KS wiring level supports serviceable K-bus I/O assemblies while the low-voltage input range suits conditioned measurement signals.

Technical specifications

Manufacturer Beckhoff Automation
Order number KS3172
Inputs 2 differential analog inputs
Signal range 0–2 V
Input resistance > 70 kΩ
Resolution 16 bit
Conversion time 140 ms, configurable
Measurement error < ±0.05% of full scale; self-calibrating
Electrical isolation 500 V between differential input and K-bus
K-bus current Typically 85 mA
Dimensions 12 × 100 × 68 mm (W × H × D)
Net weight Approximately 70 g
Protection IP20; 35 mm DIN-rail mounting

Commissioning checks

  • Confirm the sensor signal is 0–2 V; nearby KS31x2 order numbers use different voltage or current ranges.
  • Review grounding and common-mode voltage before connecting a floating or externally powered source.
  • Match process-image mapping, filter and conversion-time settings to the original terminal configuration.

Shipping data

Estimated packed size: 16 × 12 × 6 cm. Estimated shipping weight: 0.20 kg. Confirm final packed values at dispatch.

FAQ

What signal range does KS3172 accept?

It accepts two differential analog voltage inputs from 0 V to 2 V.

Why is the exact KS3172 order number important?

Other KS31x2 terminals use different voltage or current ranges. A similar housing does not indicate electrical compatibility.

What are the main accuracy characteristics?

KS3172 uses 16-bit conversion, self-calibration and a documented measurement error below ±0.05% of full scale.

What should be verified during commissioning?

Check grounding and common-mode voltage, process-image mapping, channel scaling, filter and conversion time before trusting the measured value.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

KS3172 | BECKHOFF | Bus Terminal

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details
Loading product navigation…

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1746-A7 Chassis Replacement Checks: Slots, Power and Interconnects

An engineering checklist for replacing an Allen-Bradley 1746-A7: verify chassis series, backplane loading, slot plan, interconnect cables, mounting, grounding and receiving condition.

IC200MDL650 Replacement Checks: Logic Polarity, Filters, and Commons

A field replacement guide for GE Fanuc IC200MDL650 covering revision-dependent negative logic, four common groups, 24 VDC thresholds, input filtering, carrier checks and commissioning records.

IC697CPX935 Replacement Checks: Memory, Ports, and Rack Power

A field-focused IC697CPX935 replacement guide covering fast memory, firmware-dependent serial behavior, rack power, cooling, I/O architecture and backup records.

IC693DSM324 Replacement Checks: FSSB, Firmware and Follower Control

A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.

HIMA F3430 Replacement Checks: Contact Ratings and Safety Limits

A field-focused HIMA F3430 replacement guide covering relay contact ratings, DC load derating, fusing, F3330/F3331 differences, safety restrictions and commissioning records.

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits

A field-focused IC697PWR710 replacement guide covering 5 V load calculations, dual-rack limits, extension cables, input checks, protection behavior and hardware revision risks.