Lenze

Lenze E82EV-552K2C 8200 Vector Frequency Inverter

SKU E82EV-552K2C

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Lenze

  • Product No.: E82EV-552K2C

  • Country of origin:France

  • Product Type: Vector Frequency Inverter

  • Payment: T/T, Western Union

  • Weight: 3600g

  • Dimensions: 125 x 240 x 140 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Lenze E82EV-552K2C is a vector-controlled frequency inverter designed for variable-speed motor control in industrial machines. It belongs to the 8200 vector series and uses a built-in construction for installation within an electrical enclosure. The drive incorporates motor connections, a relay output and a motor temperature monitoring input for a PTC sensor or normally closed thermal contact.

The AIF automation interface accepts optional keypad and communication modules. The FIF function interface accepts optional Standard I/O, Application I/O or fieldbus function modules. PROFIBUS-DP and INTERBUS communication requires the corresponding optional module. Drive configuration includes motor parameter identification, adjustable acceleration and deceleration, and parameter-set management.

Features

  • Parameter saving, loading, copying and restoration through C0002, with drive-to-drive parameter transfer using an optional keypad.
  • Configurable user menu for selected operating parameters and an ALL menu for access to the complete code list.
  • Motor parameter identification through C0148.
  • Direction selection, DC injection braking and fixed setpoint selection through configured digital inputs on a suitable I/O function module.
  • Red and green LEDs for operating-status indication, with fault-code display available through an optional keypad.

Applications

  • Variable-speed motor drives installed in industrial machines and electrical systems.
  • Machine drives requiring adjustable acceleration, deceleration and fixed operating setpoints.
  • Automated installations integrating drive control through optional PROFIBUS-DP or INTERBUS communication modules.

Technical Specifications

Parameter Specification
Manufacturer Lenze
Product series 8200 vector
Product type Vector-controlled frequency inverter
Construction Built-in unit
Rated power 5.5 kW
Voltage class 230 V
Drive generation C
Parameter sets 4
Parameter-set activation Digital signals configured through C0410
Default control characteristic Linear V/f
Minimum output frequency setting, C0010 Factory setting: 0.00 Hz
Maximum output frequency setting, C0011 Factory setting: 50.00 Hz
Main setpoint acceleration time, C0012 Factory setting: 5.00 s
Main setpoint deceleration time, C0013 Factory setting: 5.00 s
V/f rated frequency, C0015 Factory setting: 50.00 Hz

Connections/Interfaces

Connector Pin Function
X1.1 Integrated terminal strip for mains connection and DC supply
X1.2 Relay-output terminal strip
X2.1 Integrated terminal strip for motor connection and optional brake resistor
X2.2 Motor PTC connection or normally closed motor thermal contact
Motor PE and shield connection at X2.1 2-pole terminal strip for motor protective earth and motor cable shield
AIF Automation interface for optional E82ZBC keypad, EMZ9371BC keypad XT or type 21XX communication modules
AIF with optional fieldbus module INTERBUS through module 2111 or PROFIBUS-DP through module 2133
FIF Function interface for optional Standard I/O E82ZAFSC or Application I/O E82ZAFAC
FIF with optional fieldbus module INTERBUS through E82ZAFIC or PROFIBUS-DP through E82ZAFPC

Installation Guidelines

  • Install the inverter inside an enclosure suitable for EMC-compliant installation. Maintain metallic contact between the cabinet doors and housing, and minimize unnecessary enclosure openings.
  • Connect protective earth and secure motor and control cable shields using the designated shield connections and clamps.
  • Keep cooling surfaces and ventilation openings unobstructed. Remove accumulated contamination without damaging the cooling surfaces.
  • Disconnect the mains and any external supplies before working on terminal blocks. Wait at least 3 minutes, then verify that power terminals, relay connections and FIF contacts are de-energized.
  • Connect or disconnect pluggable terminal blocks only while the inverter is isolated from its power supply.
  • Allow at least 3 minutes between successive mains switch-on operations.
  • If a residual current device is used on the supply side, use a type B device.
  • Configure the motor parameters and operating setpoints before enabling the drive. Perform motor parameter identification through C0148 where required by the selected operating mode.

Compliance and Certifications

Directive or Standard Application
Low-Voltage Directive 2006/95/EC Controller compliance
EN 61800-5-1 Applicable harmonised standard for the controller
EN 61800-3 Installation in category C2 drive systems

FAQ

Which interface accepts the keypad for parameter setting and drive diagnostics?

The AIF automation interface accepts the optional E82ZBC keypad or EMZ9371BC keypad XT. The keypad provides parameter access, operating-status indication and fault-code display.

Can the inverter communicate with a PROFIBUS-DP or INTERBUS control system?

PROFIBUS-DP and INTERBUS communication requires the corresponding optional module. Examples include PROFIBUS-DP 2133 or INTERBUS 2111 on AIF, and E82ZAFPC or E82ZAFIC on FIF.

Where should the motor temperature sensor connect on the inverter?

The motor PTC or normally closed thermal contact connects to terminal strip X2.2. This connection provides the motor temperature monitoring input.

Can the keypad select which parameter set operates the drive?

Operating parameter sets are activated by digital signals configured through C0410. The keypad can select parameter sets 1 through 4 for editing, but does not activate them for operation.

How can an existing drive configuration be copied to another inverter?

Parameter sets can be transferred between drive controllers using the optional keypad and code C0002. The same parameter-management function supports saving, loading and copying basic settings.

How long must maintenance personnel wait before checking disconnected power terminals?

Wait at least 3 minutes after disconnecting the supply, then verify that all relevant terminals are de-energized. Relay contacts may remain energized by an external supply even when the inverter mains connection is disconnected.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Lenze E82EV-552K2C 8200 Vector Frequency Inverter

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 20 item(s) left in stock
Quantity
View full details
Loading product navigation…

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Brown
Country of origin
France

Technical knowledge

1746-A7 Chassis Replacement Checks: Slots, Power and Interconnects

An engineering checklist for replacing an Allen-Bradley 1746-A7: verify chassis series, backplane loading, slot plan, interconnect cables, mounting, grounding and receiving condition.

IC200MDL650 Replacement Checks: Logic Polarity, Filters, and Commons

A field replacement guide for GE Fanuc IC200MDL650 covering revision-dependent negative logic, four common groups, 24 VDC thresholds, input filtering, carrier checks and commissioning records.

IC697CPX935 Replacement Checks: Memory, Ports, and Rack Power

A field-focused IC697CPX935 replacement guide covering fast memory, firmware-dependent serial behavior, rack power, cooling, I/O architecture and backup records.

IC693DSM324 Replacement Checks: FSSB, Firmware and Follower Control

A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.

HIMA F3430 Replacement Checks: Contact Ratings and Safety Limits

A field-focused HIMA F3430 replacement guide covering relay contact ratings, DC load derating, fusing, F3330/F3331 differences, safety restrictions and commissioning records.

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits

A field-focused IC697PWR710 replacement guide covering 5 V load calculations, dual-rack limits, extension cables, input checks, protection behavior and hardware revision risks.