Danfoss

MBS 3000 Danfoss 060G1122 Low-Pressure Transmitter

SKU 060G1122

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 060G1122

  • Country of origin:Denmark

  • Product Type: MBS 3000 Pressure Transmitter

  • Payment: T/T, Western Union

  • Weight: 300g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The 060G1122 (060G1122) is a precision-engineered MBS 3000 series pressure transmitter from Danfoss, designed specifically for low-pressure industrial monitoring. This unit converts a measuring range of 0 - 2.5 bar into a high-stability 4 - 20 mA analog output signal. Built to withstand the rigors of industrial environments, the 060G1122 features a piezo-resistive sensing element that provides excellent repeatability and long-term stability. It is an ideal solution for applications such as tank level measurement, low-pressure pump control, and pneumatic monitoring where accuracy in a narrow pressure window is essential to maintaining process efficiency and preventing system errors.

Technical Configuration

As a part of the MBS 3000 "standard" industrial program, this transmitter is built for durability and ease of integration. It utilizes a G 1/4 A (EN 837) pressure connection, a robust threaded interface that ensures a reliable seal even under vibration. The electrical interface is handled via a standard Pg 9 (EN 175301-803-A) plug, which is highly regarded for its secure, industrial-grade connectivity. The 060G1122 is a Gauge (relative) pressure transmitter, meaning it measures system pressure in relation to current atmospheric conditions. This makes it particularly effective for open-loop ventilation systems or liquid storage tanks where maintaining a specific head pressure relative to the environment is required.

Technical Specifications

Feature Specification
Model 060G1122
Brand Danfoss
Type MBS 3000 - 1411 - 1 AB04
Measuring Range 0 - 2.5 bar
Output Signal 4 - 20 mA
Pressure Reference Gauge (Relative)
Pressure Connection G 1/4 A (EN 837)
Electrical Connection Plug Pg 9 (EN 175301-803-A)
Enclosure Rating IP65
Operating Temp -40 to 85 deg C
Net Weight 0.3 kg
Shipping Weight 1.5 kg

Technical FAQs

How accurate is the 060G1122 for low-pressure tank leveling?

The MBS 3000 series typically features a total error band of plus/minus 1% FS (Full Scale) across the compensated temperature range. For a 2.5 bar range, this provides the high resolution necessary for precise liquid level monitoring in medium-sized industrial tanks.

Can this transmitter handle media with high temperatures?

The 060G1122 is rated for medium temperatures between -40 and 85 deg C. If your application involves steam or very hot liquids, it is recommended to use a cooling syphon or capillary tube to ensure the medium temperature at the sensor face stays within these operational limits.

Is the Pg 9 plug included with the unit?

Generally, Danfoss MBS 3000 transmitters of this code include the female mating plug. However, for a complete IP65 seal, the user must ensure the cable used is compatible with the Pg 9 gland size and that the internal gasket is correctly seated during final installation.


Engineering & Installation Guide

  • Pressure Port Orientation: When measuring gas or air, install the transmitter with the pressure connection pointing downwards to allow any moisture or condensate to drain away from the sensor. For liquid applications, mount the unit horizontally or vertically to prevent air pockets from being trapped against the sensing diaphragm, which can cause reading fluctuations.

  • Electrical Loop Load: Ensure your PLC or controller's input impedance, combined with the cable resistance, does not exceed the maximum allowable load for the 4 - 20 mA loop. Typically, with a 24 VDC supply, the MBS 3000 can support a total loop resistance of approximately 600 - 700 Ohms.

  • Sealing Best Practices: When installing the G 1/4 A thread, always use a new copper or bonded seal (Dowty washer). Avoid over-tightening; use a calibrated torque wrench to apply approximately 25 Nm of torque to achieve a gas-tight seal without stressing the transmitter's stainless steel housing.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Denmark

Technical knowledge

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...