1 of 1

Mitsubishi Electric FR-A840-03610-2-60 FR-A800 Variable Frequency Drive

Mitsubishi Electric FR-A840-03610-2-60 FR-A800 Variable Frequency Drive

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-A840-03610-2-60

  • Country of origin:United States

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 80000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Engineered for highly demanding industrial automation applications, the Mitsubishi Electric FR-A840-03610-2-60 variable frequency drive provides advanced speed, torque, and vector control as part of the premier FR-A800 Series. This high-capacity, three-phase inverter is configured as a standard model featuring specialized circuit board conformal coating (Class 3C2) for superior environmental resistance in harsh operating conditions, though it does not include plated conductors. Utilizing an adaptable multi-rating architecture, it optimizes performance across various duty cycles, ensuring robust motor control and minimized downtime in complex system integrations.

Features

  • Conformal Coating (3C2): Enhanced defense against dust, humidity, and corrosive atmospheric gases.
  • Multi-Rating Flexibility: Four built-in overload ratings (SLD, LD, ND, HD) to match specific load characteristics.
  • Advanced Vector Control: Supports Real Sensorless Vector Control (RSV) and PM sensorless vector control for precise torque performance.
  • Energy-Saving Technology: Optimum excitation control maximizes motor efficiency and minimizes power consumption.
  • Comprehensive Safety Functions: Features integrated safe torque off (STO) safety inputs complying with global safety standards.

Applications

  • High-capacity water and wastewater pumping networks.
  • Industrial fan systems and air handling units with variable torque demands.
  • Extruders, mixers, and heavy-duty conveyor systems.
  • Hoisting, crane, and material handling systems requiring high starting torque.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Code FR-A840-03610-2-60
Series FR-A800 Series
Voltage Class 400V Class (Three-Phase 380V to 500V AC, 50/60Hz)
SLD Rated Current 361 A (Super Light Duty)
LD Rated Current 310 A (Light Duty)
ND Rated Current 260 A (Normal Duty)
HD Rated Current 216 A (Heavy Duty)
Structure/Functionality Standard Model (Type 0)
Board Coating With Conformal Coating (IEC 60721-3-3 Class 3C2)
Plated Conductor Without Plating
Cooling Method Forced Air Cooling
Operating Temperature -10 degC to +50 degC (non-freezing, matching rated load capacity)
Shipping Weight (Calculated) 80.0 kg

Connections and Interfaces

Terminal Group Description & Assignment
R/L1, S/L2, T/L3 Three-phase AC power input supply terminals
U, V, W Three-phase AC output connections to the motor
STF / STR Forward Start / Reverse Start digital input control commands
SD / PC Common terminal for contact input / External transistor power source (24VDC)
A1, B1, C1 Relay output terminals (Fault output indicator)

Empirical Engineering Insights

Alternative Models & Compatibility

When replacing an older legacy series inverter (such as the FR-A740 series), keep in mind that control terminal configurations are substantially compatible, but terminal block positioning and dimensions may vary. The "-2-60" suffix indicates this drive features specialized 3C2 conformal board coating; it serves as a direct, rugged upgrade to standard uncoated variants (such as the base FR-A840-03610) without modifying any application parameters or cabinet configurations.

Application Pitfalls & Engineering Notes

At the 361A Super Light Duty rating, the drive is highly sensitive to input supply phase imbalances. Ensure line-side voltage deviation does not exceed 3% between phases to prevent localized overheating in the input rectifier bridge. Because this model does not feature plated conductors, avoid deploying this specific configuration in environments with active exposure to direct hydrogen sulfide gas unless the main enclosure is sealed to an IP54 or higher standard and utilizes external heat exchanges.

Commissioning & Wiring Tips

Verify the position of the slide switch on the control terminal circuit board to correctly select between SINK (NPN) and SOURCE (PNP) logic states before powering up the drive's control circuitry. Improper selection may lead to internal control board damage or unexpected behavior of digital inputs. Keep control signal wiring separated from high-power motor cabling by at least 30 cm, crossing them only at right angles to minimize electro-magnetic interference (EMI).

Installation Guidelines

CRITICAL WARNING: HIGH VOLTAGE HAZARD

Isolate all electrical power sources before performing mechanical installation or internal wiring. Verify that the DC bus charge indicator LED on the front cover is completely unlit, and measure the voltage across terminal blocks P/+ and N/- using a calibrated voltmeter to ensure it is below 45V DC. Failure to follow discharge protocol can result in catastrophic shock or fatal injury.

1

Mount the inverter vertically to a rigid, non-flammable vertical support panel. Ensure at least 10 cm of clear vertical space above and below the unit to allow free airflow from the forced cooling fans.

2

Connect the dedicated ground terminal to the main system grounding point using heavy gauge wire conforming to local electrical codes to mitigate high-frequency leakage currents.

3

Wire the main power input terminals (R/L1, S/L2, T/L3) and the motor output terminals (U, V, W) using appropriately sized cable lugs torqued precisely to the manufacturer's specified tightening values.

Loading product navigation…

What is the primary function of the -60 suffix in this specific model?

The -60 suffix specifies that the control and power circuit boards are protected with an IEC 60721-3-3 Class 3C2 conformal coating, which provides safety and corrosion resistance in highly humid or dusty environments.

Does this model come equipped with plated conductors?

No, this specific configuration (FR-A840-03610-2-60) is configured without plated conductors.

What are the output current ratings for the different duty cycles of this drive?

This drive features multiple ratings: Super Light Duty (SLD) is 361A, Light Duty (LD) is 310A, Normal Duty (ND) is 260A, and Heavy Duty (HD) is 216A.

Can I use this inverter in an environment with high vibrational stress?

Yes, standard mechanical mounting with adequate vibration dampening is recommended. The heavy-duty physical chassis is designed for panel installations inside robust industrial cabinets.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...