Mitsubishi Electric

Mitsubishi Electric FR-F840-01800-2-60 FR-F800 Series Inverter

SKU FR-F840-01800-2-60

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-F840-01800-2-60

  • Country of origin:United States

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 43000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed for energy-saving ventilation, fan, and pump control, the FR-F840-01800-2-60 functions as a highly efficient variable frequency drive within the Mitsubishi Electric FR-F800 Series. Engineered for high-demand industrial systems, this industrial inverter regulates motor speeds with precise frequency control to optimize power consumption and system longevity.

This specific configuration includes a specialized circuit board coating (designated by suffix -60) to protect internal components against harsh environmental elements, though it does not utilize plated conductors. The CA specification (indicated by symbol 2) optimizes this drive for complex infrastructure and industrial utility setups requiring robust electromagnetic compatibility and high-capacity electrical performance.

Features

  • Compatible with motors up to 75 kW capacity.
  • Specially coated circuit board (-60 option) for enhanced protection against dust and moisture.
  • Forced air cooling system ensures stable thermal performance during heavy duty cycles.
  • Broad permissible AC voltage tolerance from 323 V to 550 V.
  • Open-type IP00 protective structure designed for clean integration into control cabinets.

Applications

  • Industrial pump control and water treatment facilities
  • HVAC ventilation systems and large-scale industrial fans
  • Factory automation and process cooling towers
  • Material handling and conveyor systems

Technical Specifications

Manufacturer Mitsubishi Electric
Model / Part Number FR-F840-01800-2-60
Series FR-F800
Applicable Motor Capacity 75 kW
Rated Output Capacity 137 kVA
Rated Output Current 180 A
Output Voltage Three-phase 380 to 500 V
Rated Input AC Voltage/Frequency Three-phase 380 to 500 V 50 Hz/60 Hz
Permissible AC Voltage Fluctuation 323 to 550 V 50 Hz/60 Hz
Permissible Frequency Fluctuation plus/minus 5%
Power Supply Capacity 137 kVA
Protective Structure (JEM1030) Open type (IP00)
Cooling System Forced air cooling
Weight 43 kg

Installation Guidelines

  • Mounting: Install vertical to the mounting surface inside a suitable, ventilated electrical enclosure to satisfy IP ratings and protect the IP00 open structure from contaminants.
  • Cooling Clearance: Ensure unobstructed intake and exhaust pathways for the forced air cooling system to maintain safe internal temperatures.
  • Power Supply Protection: Confirm that line voltage fluctuations stay within the permissible 323 V to 550 V range to avoid overvoltage faults.
  • Grounding: Connect to a dedicated, low-impedance ground point to ensure EMC compliance and operator safety.

FAQ

What is the applicable motor capacity of the FR-F840-01800-2-60 inverter?

The FR-F840-01800-2-60 inverter is designed to drive three-phase induction motors with a capacity of up to 75 kW.

What environmental protections does the -60 suffix provide?

The -60 suffix indicates that the circuit boards feature a protective coating to guard against corrosion and moisture, though it does not feature plated conductors.

Does this inverter require an external cooling mechanism?

No, the drive features an integrated forced air cooling system, but it must be installed with sufficient clearance inside a ventilated enclosure to operate within safe limits.

What is the enclosure rating of this model?

This inverter has an open-type IP00 protective structure (JEM1030) and is intended to be mounted inside a protective control cabinet.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Designing Power and Communication Redundancy

Design control-system redundancy by mapping shared dependencies, separating power and network paths, defining failover behavior, exposing degraded operation, and proof-testing every tolerated fault.

Troubleshooting Industrial Control Cabinets Systematically

A structured control-cabinet troubleshooting method covering safe work, drawings, power paths, branch protection, DC supplies, return circuits, PLC outputs, fault records and repair verification.

Measuring Voltage in Industrial Control Circuits

A practical voltage-testing guide for industrial control panels, covering reference points, meter selection, live-dead-live checks, voltage drop, ghost voltage, stored energy and intermittent faults.

Building a Verifiable Lockout Tagout Procedure

A practical lockout tagout guide covering hazardous-energy identification, isolation, stored-energy control, verification, group work, temporary testing, restoration, inspections and audits.

Designing Compressed-Air Preparation at the Machine

A field guide to point-of-use compressed-air preparation covering filters, regulators, drains, dryers, lubrication, pressure loss, isolation, monitoring, commissioning and leak testing.

Selecting Pneumatic Valve Actuation and Safe States

A practical guide to manual, pilot and solenoid pneumatic valves, covering port functions, monostable and bistable behavior, PLC outputs, safe states, commissioning and fault diagnosis.