Managing up to 80 physical local I/O points, the Mitsubishi Electric FX2N-80MR-DS serves as a high-speed, DC-powered controller within the legacy FX2N micro-PLC architecture. This base unit integrates processing, memory, and high-density input/output control in a single compact chassis. Operating on a nominal 24V DC power supply, it is engineered for field environments where AC mains are unavailable or where battery-backed power systems are mandatory. The platform features 40 digital inputs and 40 relay outputs, providing robust isolation and high switching capacity for diverse industrial actuators and sensors.
| Parameter | Specification Value |
|---|---|
| Manufacturer | Mitsubishi Electric |
| Model Reference | FX2N-80MR-DS |
| Product Series | MELSEC FX2N Series |
| Operating Voltage | 24V DC (+20% / -15%) |
| Total I/O Points | 80 Points |
| Digital Inputs | 40 Points (24V DC, Sink/Source) |
| Digital Outputs | 40 Points (Relay, isolated) |
| Max. Relay Load Current | 2A per point; 8A per group (4 points); 30V DC / 240V AC max. |
| Program Memory | 16,000 steps (RAM/EEPROM internal or optional cassette) |
| Response Time | Inputs: approx. 10 ms; Outputs: approx. 10 ms (relay mechanical lag) |
| Internal Current Consumption | 40W (Maximum power consumption) |
| Country of Origin | Japan |
| Shipping Weight (Calculated) | 1.45 kg |
| Package Dimensions (Calculated) | 310 mm x 115 mm x 110 mm |
| Terminal Designation | Function / Connection Specification |
|---|---|
| + / - (Power) | Primary 24V DC input supply terminals. |
| S / S Terminal | Input common terminal. Connect to 24V for Sink (NPN) configuration or 0V for Source (PNP) configuration. |
| X000 to X047 | 40 channel digital inputs. X000 to X005 are high-speed counter compatible. |
| COM0 to COM7 | Common return terminals for isolated relay output groups. |
| Y000 to Y047 | 40 channel physical relay contacts. External circuit fuses should be matched to load groupings. |
The FX2N-80MR-DS is an older classic micro-PLC architecture. If you are retrofitting or replacing an older FX2-80MR-D, the FX2N model offers equivalent physical spacing but operates with substantially faster processing speeds and a larger instruction library. For modern migrations, note that the FX2N range is superseded by the MELSEC iQ-F (FX5U) series. Upgrading to an FX5U-80MR/DS requires an FX5-CNV-BUS bus conversion module to retain any downstream legacy FX2N expansion units.
Relay wear is the most common failure vector for this device in high-duty environments. When driving inductive loads (such as DC solenoid valves or motor contactor coils), you must install an external flyback diode (for DC loads) or an RC snubber circuit (for AC loads) across the load. Failure to do so will cause contact arcing, degrading the internal relays and leading to premature weld-shut failures. Maintain clear ventilation space around the PLC; ambient operating temperatures inside the panel must not exceed 55 degC.
Ensure the S/S (Sink/Source) terminal is tied directly to the correct reference voltage before powering the unit. Leaving this floating will result in digital inputs failing to register. If routing encoder lines into X000 through X005, use high-quality twisted pair shielded cabling and terminate the shield at a single point near the panel ground bar to suppress high-frequency EMI.
Global Express Shipping
Returns & Warranty

Managing up to 80 physical local I/O points, the Mitsubishi Electric FX2N-80MR-DS serves as a high-speed, DC-powered controller within the legacy FX2N micro-PLC architecture. This base unit integrates processing, memory, and high-density input/output control in a single compact chassis. Operating on a nominal 24V DC power supply, it is engineered for field environments where AC mains are unavailable or where battery-backed power systems are mandatory. The platform features 40 digital inputs and 40 relay outputs, providing robust isolation and high switching capacity for diverse industrial actuators and sensors.
| Parameter | Specification Value |
|---|---|
| Manufacturer | Mitsubishi Electric |
| Model Reference | FX2N-80MR-DS |
| Product Series | MELSEC FX2N Series |
| Operating Voltage | 24V DC (+20% / -15%) |
| Total I/O Points | 80 Points |
| Digital Inputs | 40 Points (24V DC, Sink/Source) |
| Digital Outputs | 40 Points (Relay, isolated) |
| Max. Relay Load Current | 2A per point; 8A per group (4 points); 30V DC / 240V AC max. |
| Program Memory | 16,000 steps (RAM/EEPROM internal or optional cassette) |
| Response Time | Inputs: approx. 10 ms; Outputs: approx. 10 ms (relay mechanical lag) |
| Internal Current Consumption | 40W (Maximum power consumption) |
| Country of Origin | Japan |
| Shipping Weight (Calculated) | 1.45 kg |
| Package Dimensions (Calculated) | 310 mm x 115 mm x 110 mm |
| Terminal Designation | Function / Connection Specification |
|---|---|
| + / - (Power) | Primary 24V DC input supply terminals. |
| S / S Terminal | Input common terminal. Connect to 24V for Sink (NPN) configuration or 0V for Source (PNP) configuration. |
| X000 to X047 | 40 channel digital inputs. X000 to X005 are high-speed counter compatible. |
| COM0 to COM7 | Common return terminals for isolated relay output groups. |
| Y000 to Y047 | 40 channel physical relay contacts. External circuit fuses should be matched to load groupings. |
The FX2N-80MR-DS is an older classic micro-PLC architecture. If you are retrofitting or replacing an older FX2-80MR-D, the FX2N model offers equivalent physical spacing but operates with substantially faster processing speeds and a larger instruction library. For modern migrations, note that the FX2N range is superseded by the MELSEC iQ-F (FX5U) series. Upgrading to an FX5U-80MR/DS requires an FX5-CNV-BUS bus conversion module to retain any downstream legacy FX2N expansion units.
Relay wear is the most common failure vector for this device in high-duty environments. When driving inductive loads (such as DC solenoid valves or motor contactor coils), you must install an external flyback diode (for DC loads) or an RC snubber circuit (for AC loads) across the load. Failure to do so will cause contact arcing, degrading the internal relays and leading to premature weld-shut failures. Maintain clear ventilation space around the PLC; ambient operating temperatures inside the panel must not exceed 55 degC.
Ensure the S/S (Sink/Source) terminal is tied directly to the correct reference voltage before powering the unit. Leaving this floating will result in digital inputs failing to register. If routing encoder lines into X000 through X005, use high-quality twisted pair shielded cabling and terminate the shield at a single point near the panel ground bar to suppress high-frequency EMI.
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
United States
|