Mitsubishi Electric

Mitsubishi Electric FX5U-80MT/DS MELSEC iQ-F Series CPU Module

SKU FX5U-80MT/DS

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Mitsubishi Electric
  • Product No.: FX5U-80MT/DS
  • Origin United States
  • Product Type: CPU Modules
  • Payment: T/T, Western Union
  • Weight: 2.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

Designed to anchor high-performance industrial automation systems, the FX5U-80MT/DS serves as a highly capable central processing unit within the Mitsubishi Electric MELSEC iQ-F platform. This controller integrates substantial onboard memory, embedded communication interfaces, and extensive expansion capabilities. Engineering teams utilize this module to manage complex machine control tasks, leveraging its high-density digital input/output structure and rapid execution speeds to optimize factory automation processes.

The unit features 40 digital inputs and 40 transistor outputs directly on its compact chassis, operating on a nominal 24 V DC power system. Field wiring connections are established via rugged screw terminal blocks, ensuring physical stability in high-vibration industrial environments. The underlying architecture supports multi-protocol network communication and precise motion control functionality, making it a reliable choice for modern control panels.

Features

  • Integrated high-density digital control with 40 inputs and 40 outputs.
  • Robust screw terminal block interfaces for high-reliability physical connections.
  • Built-in 5 V DC internal power supply capacity of 1100 mA.
  • Built-in 24 V DC service power supply capacity of 770 mA.
  • Transistor outputs suited for high-frequency switching and precise pulse-train generation.
  • Embedded Ethernet and RS-485 ports facilitating seamless network integration.

Applications

  • Automated assembly lines and high-speed packaging machinery.
  • Material handling, sorting, and conveyor system control.
  • Water and wastewater pump control panels.
  • HVAC control and general building automation systems.

Technical Specifications

ParameterSpecification
Manufacturer Mitsubishi Electric
Model/Part Number FX5U-80MT/DS
Series MELSEC iQ-F Series
Product Type CPU Module
Total I/O Points 80 points
Number of Input Points 40 points
Input Type 24 V DC (sink)
Number of Output Points 40 points
Output Type Transistor
Connection Type Screw terminal block
Internal 5 V DC Power Supply Capacity 1100 mA
Internal 24 V DC Power Supply Capacity 770 mA
Operating Voltage 24 V DC
Shipping Weight 2 kg

Installation Guidelines

Prior to mounting, ensure all power sources are disconnected. Install the unit on a standard 35 mm DIN rail using the integrated mounting clips, or secure it directly to a backplate using the designated mounting holes. Maintain a minimum ventilation clearance of 50 mm above and below the module to prevent thermal buildup inside the enclosure. Wire the screw terminal blocks according to the manufacturer's torque specifications, ensuring the system ground terminal is connected to a dedicated class D ground (100 ohms or less) using a minimum 2 mm square grounding wire.

Compliance and Certifications

  • CE (Conformite Europeenne)
  • UL Listed (Underwriters Laboratories)
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary power supply requirement for the FX5U-80MT/DS?
The FX5U-80MT/DS operates on a nominal external power supply of 24 V DC.
How many integrated I/O points does this CPU module provide?
The module provides a total of 80 built-in I/O points, consisting of 40 digital inputs (sink type) and 40 transistor outputs.
What is the internal current capacity of the integrated power supplies?
It provides up to 1100 mA on the 5 V DC bus and 770 mA on the 24 V DC bus for powering connected expansion modules and internal circuits.
What termination method is used for field wiring on the FX5U-80MT/DS?
The controller uses integrated screw terminal blocks to ensure secure, vibration-resistant wiring connections.
Reviews

FX5U-80MT/DS

Stock & lead time on request

Call
1 of 1

Mitsubishi Electric FX5U-80MT/DS MELSEC iQ-F Series CPU Module

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FX5U-80MT/DS

  • Country of origin:United States

  • Product Type: CPU Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed to anchor high-performance industrial automation systems, the FX5U-80MT/DS serves as a highly capable central processing unit within the Mitsubishi Electric MELSEC iQ-F platform. This controller integrates substantial onboard memory, embedded communication interfaces, and extensive expansion capabilities. Engineering teams utilize this module to manage complex machine control tasks, leveraging its high-density digital input/output structure and rapid execution speeds to optimize factory automation processes.

The unit features 40 digital inputs and 40 transistor outputs directly on its compact chassis, operating on a nominal 24 V DC power system. Field wiring connections are established via rugged screw terminal blocks, ensuring physical stability in high-vibration industrial environments. The underlying architecture supports multi-protocol network communication and precise motion control functionality, making it a reliable choice for modern control panels.

Features

  • Integrated high-density digital control with 40 inputs and 40 outputs.
  • Robust screw terminal block interfaces for high-reliability physical connections.
  • Built-in 5 V DC internal power supply capacity of 1100 mA.
  • Built-in 24 V DC service power supply capacity of 770 mA.
  • Transistor outputs suited for high-frequency switching and precise pulse-train generation.
  • Embedded Ethernet and RS-485 ports facilitating seamless network integration.

Applications

  • Automated assembly lines and high-speed packaging machinery.
  • Material handling, sorting, and conveyor system control.
  • Water and wastewater pump control panels.
  • HVAC control and general building automation systems.

Technical Specifications

ParameterSpecification
Manufacturer Mitsubishi Electric
Model/Part Number FX5U-80MT/DS
Series MELSEC iQ-F Series
Product Type CPU Module
Total I/O Points 80 points
Number of Input Points 40 points
Input Type 24 V DC (sink)
Number of Output Points 40 points
Output Type Transistor
Connection Type Screw terminal block
Internal 5 V DC Power Supply Capacity 1100 mA
Internal 24 V DC Power Supply Capacity 770 mA
Operating Voltage 24 V DC
Shipping Weight 2 kg

Installation Guidelines

Prior to mounting, ensure all power sources are disconnected. Install the unit on a standard 35 mm DIN rail using the integrated mounting clips, or secure it directly to a backplate using the designated mounting holes. Maintain a minimum ventilation clearance of 50 mm above and below the module to prevent thermal buildup inside the enclosure. Wire the screw terminal blocks according to the manufacturer's torque specifications, ensuring the system ground terminal is connected to a dedicated class D ground (100 ohms or less) using a minimum 2 mm square grounding wire.

Compliance and Certifications

  • CE (Conformite Europeenne)
  • UL Listed (Underwriters Laboratories)

What is the primary power supply requirement for the FX5U-80MT/DS?

The FX5U-80MT/DS operates on a nominal external power supply of 24 V DC.

How many integrated I/O points does this CPU module provide?

The module provides a total of 80 built-in I/O points, consisting of 40 digital inputs (sink type) and 40 transistor outputs.

What is the internal current capacity of the integrated power supplies?

It provides up to 1100 mA on the 5 V DC bus and 770 mA on the 24 V DC bus for powering connected expansion modules and internal circuits.

What termination method is used for field wiring on the FX5U-80MT/DS?

The controller uses integrated screw terminal blocks to ensure secure, vibration-resistant wiring connections.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...