1 of 3

Mitsubishi Electric GCU08CB-130 80173-109-01-3 GCT Thyristor Unit

Mitsubishi Electric GCU08CB-130 80173-109-01-3 GCT Thyristor Unit

Only 7 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: GCU08CB-130 80173-109-01-3

  • Country of origin:United States

  • Product Type: GCT Thyristor Unit

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1140g

  • Dimensions: 25cm x 20.7cm x 5.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Mitsubishi Electric GCU08CB-130 is a symmetrical, high-power GCT (Gate Commutated Turn-off) Thyristor Unit integrated with an onboard gate driver. This press-pack semiconductor device features a specialized internal circuit board marked under reference code 80173-109-01-3. It is engineered explicitly for demanding switching actions in current source inverters, heavy-duty DC choppers, induction heating networks, and high-capacity DC to DC power converters. By permanently binding the GCT component to its gate driver on a unified motherboard, the assembly significantly reduces stray circuit loop inductance, ensuring rigid gate pulse synchronization and highly repetitive controllable off-state handling in modular industrial drive frameworks.

Features

  • Seamlessly combines a high-voltage GCT thyristor device with a matched gate driver on a direct-coupled motherboard assembly to eliminate external wiring loop inductance.
  • Implements robust electrical isolation via an optical fiber data link infrastructure utilizing standard Broadcom transceivers for control pulses.
  • Equipped with physical onboard troubleshooting infrastructure including a green power supply validation LED, a green gate indicator LED, and precise signal test points.
  • Utilizes a highly ruggedized press-pack structural casing optimized for clean mechanical mounting pressure alignment and uniform thermal heat sink interfacing.

Applications

  • High-power current source inverters and industrial drive systems.
  • Industrial DC choppers and multi-rail voltage step-conversion units.
  • High-frequency industrial induction heaters and metallurgical processing power panels.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric Corporation
Model Number GCU08CB-130
Internal Motherboard Reference Code 80173-109-01-3
Product Classification GCT Thyristor Unit
Housing Construction Type Press Pack Type
Repetitive Peak Reverse Voltage (VRRM) 6500 V
Non-Repetitive Peak Reverse Voltage (VRSM) 6500 V
Repetitive Peak Off-State Voltage (VDRM) 6500 V
Non-Repetitive Peak Off-State Voltage (VDSM) 6500 V
Long Term DC Stability Voltage (V(LTDS)) 3600 V
RMS On-State Current (IT(RMS)) 800 A
Average On-State Current (IT(AV)) 520 A maximum (330 A nominal)
Repetitive Controllable On-State Current (ITQRM) 800 A
Surge On-State Current (ITSM) 4.8 kA maximum
Current-Squared, Time Integration Max Value (I2t) 7.6 x 10^4 A^2s
Critical Rate of Rise of On-State Current (diT/dt) 1000 A/microsecond
Critical Rate of Rise of Reverse Recovery Current (diR/dt) 1000 A/microsecond
Peak Forward Gate Power Dissipation (PFGM) 5 kW
Peak Reverse Gate Power Dissipation (PRGM) 17 kW
Average Forward Gate Power Dissipation (PFG(AV)) 100 W
Average Reverse Gate Power Dissipation (PRG(AV)) 120 W
Peak Forward Gate Voltage (VFGM) 10 V
Peak Reverse Gate Voltage (VRGM) 21 V
Peak Forward Gate Current (IFGM) 500 A
Peak Reverse Gate Current (IRGM) 800 A
Gate Driver Power Supply Input Voltage (VGIN) 20 V DC nominal (19 - 21 V DC acceptable window)
Gate Driver Power Consumption (PGIN) 35 W
Mechanical Clamping Force Requirement (FM) 11.1 to 15.8 kN (13 kN nominal benchmark)
Thyristor Pole Piece Diameter 47 mm
Assembly Housing Total Thickness 26 mm
Net Structural Weight 1060 g
Junction Operating Temperature Window (Tj) -20 to 125 Celsius
Ambient Storage Temperature Range (Tstg) -40 to 60 Celsius
Ambient Operating Temperature Bounds (Ta) -10 to 60 Celsius (Recommended threshold: <= 40 Celsius)
Thermal Resistance Junction-to-Fin (Rt(j-f)) 0.025 K/W

Connections/Interfaces

Port Component Identifier Interface Mapping / Engineering Function
Power Supply Connector Phoenix Contact Type MSTB25/2-G-5.08 plug-in port for 20 V DC gate driver power entry
Fiber Optic Input Port HFBR-2521Z Broadcom Optical Receiver for control pulse entry
Fault Signal Output Port HFBR-1521Z Broadcom Optical Transmitter for system response mapping
GATE TEST POINT Onboard probe node for real-time gate voltage diagnosis
CATHODE TEST POINT Onboard probe node mapping the cathode electrical reference return
LED A (Green) Visual confirmation status showing Power Supply OK
LED B (Green) Visual confirmation status mapping Gate conditions

Installation Guidelines

  • Clamping Pressure Execution: Install the unit within a calibrated compression rig ensuring a steady mechanical mounting force within the 11.1 kN to 15.8 kN range to establish proper electrical contact and minimize internal interface thermal resistance.
  • Fiber Link Protection: Keep the Broadcom HFBR-2521Z and HFBR-1521Z optical headers clean and free of contamination. Avoid tight component wiring bends to prevent control command signal attenuation.
  • Gate Supply Limits: Wire a regulated auxiliary DC supply ensuring voltage remains within the 19 to 21 V DC bounds directly at the board's two-pin connector plug to avoid driver switching delay anomalies.
Key Features:

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Mitsubishi Electric GCU08CB-130 80173-109-01-3 GCT Thyristor Unit

What is the relationship between model GCU08CB-130 and the number 80173-109-01-3?

The official commercial model of the complete GCT thyristor assembly is GCU08CB-130, whereas 80173-109-01-3 represents the specific factory internal artwork printing tracking number on the integrated gate driver circuit board.

What happens if the power feed to the gate driver connector varies outside the specified range?

The gate driver board requires a highly stable input voltage between 19 and 21 V DC. Operating outside these boundaries can destabilize switching timing and potentially lead to permanent semiconductor module breakdown.

What are the recommended environmental temperature boundaries for safe device operation?

The device operates safely across a junction temperature range of -20 to 125 Celsius, and an ambient operating temperature range of -10 to 60 Celsius, though keeping ambient temperatures at or below 40 Celsius is recommended for optimized longevity.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Micro Drive Specialist EMS Bets on Custom Engineering to Broaden Market Appeal

UK micro-drive specialist EMS is pairing Faulhaber high-torque gearheads and compact motion controllers with in-house custom engineering—aiming beyond catalog sales into tailored mechatronics.

Bringing Object-Oriented Thinking to PLC Programming

Copy-paste ladder does not scale. Object-oriented PLC techniques—user-defined structures and instructions—cut duplication, propagate fixes once, and keep large multi-device programs readable.

Why Process Safety Management Programs Fail Even When OSHA Boxes Are Checked

OSHA boxes checked is not the same as a living PSM system. Refinery history shows programs fail when procedures, training, contractors, and investigations drift from how the plant actually runs.

What Is SCADA? Supervisory Control Without Replacing the PLC

SCADA sits above PLCs and RTUs: it acquires field data, alarms operators, and issues supervisory commands across plants and remote assets—without replacing local deterministic control.

What Is a VFD? Variable Frequency Drives That Actually Move the Needle

A VFD turns fixed-frequency mains into controlled voltage and frequency so AC motors match real load—cutting pump and fan energy while tightening torque, soft-start, and braking behavior.

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.