Mitsubishi Electric

Mitsubishi Electric GT1155HS-QSBD GOT1000 Series Handy Touch-Screen HMI

SKU GT1155HS-QSBD

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Mitsubishi Electric

  • Product No.: GT1155HS-QSBD

  • Country of origin:United States

  • Product Type: Touch-Screen HMIs

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed for mobile operation and direct machine-side control, the GT1155HS-QSBD serves as a rugged, handheld human-machine interface (HMI) within the Mitsubishi Electric GOT1000 platform. This "Handy" series operator terminal integrates physical tactile controls and high-reliability safety features directly into the portable housing, making it optimal for manual machine setups, teaching operations, and local debugging tasks.

The unit features a bright 5.7-inch STN color display with a QVGA resolution of 320 x 240 pixels. To ensure safe operation in manual mode, the device incorporates physical operator controls, including six application switches, a key-operated selector switch, and a three-position grip switch (enabling/deadman switch). Equipped with multi-channel serial connectivity and storage expandability via CompactFlash, this terminal interfaces seamlessly with MELSEC PLCs and other industrial controllers.

Features

  • Industrial Handy Form Factor: Mobile design engineered for safe, tethered hand-held operations in demanding environments.
  • Integrated Safety Elements: Built-in 3-position grip switch (OFF-ON-OFF) and a 2-position key selector switch for secure operator authorization.
  • Vibrant Touch Display: 5.7-inch STN liquid crystal screen displaying 256 colors with adjustable contrast and multi-step brightness control.
  • Versatile Serial Interfaces: Main communication via a robust round 32-pin connector supporting RS-422 and RS-232 protocols, supplemented by a standard Mini-DIN 9-pin RS-232 programming port.
  • Expandable Storage: Equipped with a Type I CompactFlash (CF) card slot for rapid OS installation, project backup, and recipe logging.
  • Robust IP Rating: Built to meet IP65F standards (JEM 1030) for protection against water spray, oil mist, and dust ingress.

Applications

  • Robotic cell programming and teach pendant operations.
  • Automotive assembly line setup and manual overrides.
  • Field maintenance, calibration, and localized commissioning.
  • Packaging, sorting, and material handling system troubleshooting.

Technical Specifications

ManufacturerPart Number / ModelSeriesDisplay TypeScreen SizeResolutionDisplay ColorsTouch Panel TypeFlash MemorySRAM CapacityPrimary Communication PortPC Interface PortStorage InterfaceOperation SwitchesGrip SwitchKey Selector SwitchPower Supply VoltagePower ConsumptionEnvironmental RatingOperating TemperatureStorage TemperatureDimensionsWeight
Mitsubishi Electric
GT1155HS-QSBD
GOT1000 (GOT11 Handy)
STN Color Liquid Crystal
5.7 inches (115 mm W x 86 mm H)
320 x 240 pixels (QVGA)
256 colors
Matrix resistive membrane (300 keys per screen)
3 MB (for project data and OS)
512 KB (for alarm history and recipe storage)
RS-422/RS-232 shared via 32-pin round male connector
RS-232 (Mini-DIN 9-pin female) & USB (Full Speed 12 Mbps)
CompactFlash (CF) Slot Type I
6 mechanical switches (a-contact, max 10 mA / 24 VDC)
3-position deadman switch (max 1 A / 24 VDC resistive)
2-notch type (1c contact, max 1 A / 24 VDC resistive)
24 VDC (+10%, -15%)
9.84 W or less (410 mA at 24 VDC)
IP65F (JEM 1030)
0 to 40 degC
-20 to 60 degC
176 mm (W) x 220 mm (H) x 93 mm (D)
1.0 kg (excluding connection cable)

Connections and Interfaces

Interface Type Connector / Slot Shape Functional Assignment
Main Connection Round 32-pin (Male) RS-422/232 communication to host controller, power supply input, and safety switch hardwiring
PC Connection Mini-DIN 9-pin (Female) RS-232 interface for project uploading, downloading, and OS installation
USB Port Mini-B High-speed transfer interface and FA transparent link
CF Slot Type I CompactFlash Data backup, recipe transfer, and system OS updates

Installation Guidelines

  • Cable Management: Route the 32-pin system cable away from high-voltage AC lines or motor power cables to minimize electromagnetic interference (EMI).
  • Port Protection: Ensure the rubber environmental caps are securely sealed over the Mini-DIN and USB ports when not actively connected to a configuration PC to maintain the IP65F rating.
  • Grounding: Connect the dedicated functional ground conductor in the host-side cable assembly to a low-impedance industrial ground point.
  • Operating Environment: Avoid exposing the HMI display panel to direct sunlight for prolonged periods to prevent thermal buildup and localized polarization of the liquid crystal layer.

Compliance and Certifications

  • UL / cUL Listed
  • CE (EMC Directive)
  • CE (RoHS Directive)
  • KC (Korea Certification)

FAQ

What is the primary function of the grip switch on the GT1155HS-QSBD?

The grip switch acts as an enabling or deadman safety switch. It has a three-position mechanical function (OFF-ON-OFF) designed to stop machine movements immediately if the operator squeezes or releases the switch during hazardous operations.

Which communication ports are available on this handy HMI?

It features a round 32-pin main connector (supporting RS-422/RS-232), a dedicated RS-232 Mini-DIN 9-pin female port, and a Full Speed USB device port for programming.

Can the backlight tube in this HMI be replaced by the end-user?

No, the cold cathode tube backlight is not designed to be replaced by the user. However, the HMI has a built-in backlight break detection function to notify operators of failures.

What memory cards does the GT1155HS-QSBD support?

The unit features one Type I CompactFlash (CF) card slot used for transferring data, storing system parameters, and installing the HMI operating system.

What is the recommended power input for this HMI?

It requires a nominal input supply voltage of 24 VDC with an allowable ripple voltage of 200 mV or less, operating within a range of +10% to -15%.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Securing Remote PLC Access Beyond the VPN

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...