Manufacturer: Mitsubishi Electric
Product No.: GT2508-VTBA
Country of origin:United States
Product Type: HMI Panels
Payment: T/T, Western Union
Weight: 8000g
Dimensions: 310 mm x 260 mm x 120 mm
Shipping port: Xiamen
Warranty: 12 months
Engineered for seamless integration into high-performance industrial control architectures, the Mitsubishi Electric GT2508-VTBA represents a reliable, mid-range visualization solution within the GOT2000 Series. Featuring an 8.4-inch TFT color LCD with VGA resolution (640 x 480 dots), this Graphic Operation Terminal delivers exceptional visual clarity and responsive control for demanding factory floor environments. The display supports up to 65,536 colors, enabling detailed graphical schematics, alarm histories, and real-time trend graphs. Operated via an analog resistive touch film, the interface accommodates precise multi-touch control and gestures even while operators wear industrial gloves.
This HMI operates on a universal AC power supply rating of 100-240 VAC, ensuring global compatibility across diverse electrical grids. Built-in communications include Ethernet, RS-232, and RS-422/485 serial ports, allowing direct communication with PLCs, variable frequency drives, and servo systems without requiring additional communication modules. The black frame design and IP67F-rated front panel ensure long-term durability when panel-mounted in environments exposed to dust, oil mist, and water spray.
| Manufacturer | Mitsubishi Electric |
| Model Number | GT2508-VTBA |
| Series Name | GOT2000 (GT25) |
| Display Type | TFT Color LCD |
| Screen Size | 8.4 inch (21.3 cm) diagonal |
| Resolution | VGA (640 x 480 dots) |
| Display Size (W x H) | 170.9 mm x 128.2 mm |
| Touch Panel Type | Analog resistive film |
| Frame Color | Black |
| Supply Voltage | 100 to 240 VAC |
| Input Frequency | 50 / 60 Hz (+/- 5%) |
| Power Consumption | Maximum 41 W (or less) |
| Panel Cutout (W x H) | 227 mm x 176 mm |
| External Dimensions (W x H x D) | 241 mm x 194 mm x 52 mm |
| Weight (Excluding Brackets) | 1.5 kg |
| Shipping Weight (Calculated) | 2.5 kg |
| Package Dimensions (Calculated) | 310 mm x 260 mm x 120 mm |
| Interface Port | Functional Specifications |
|---|---|
| Ethernet Port | 1 Channel (RJ45 connector), 10BASE-T/100BASE-TX for network and controller integration. |
| RS-232 | 1 Channel (D-Sub 9-pin male), transmission speeds up to 115,200 bps. |
| RS-422/485 | 1 Channel (D-Sub 9-pin female), for multi-drop connections to PLCs and temperature controllers. |
| USB Host | 1 Channel (Type-A USB 2.0 High-Speed) for connecting USB storage devices or keyboards. |
| USB Device | 1 Channel (Mini-B USB 2.0 High-Speed) for PC transfer of project screens and program debugging. |
| SD Card Slot | 1 Slot (SDHC compatible) for logging system operational data and storing screen layout backups. |
When replacing legacy GT15 or GT16 series 8.4-inch HMIs with the GT2508-VTBA, confirm the physical cabinet cutout. While outer dimensions and cutout sizes are matching in most instances, the back-panel protrusion depth differs slightly. Furthermore, screen data created on GT Designer2 must be upgraded to GT Works3 (version 1.100E or later) to match the higher hardware specifications and updated communications libraries of the GOT2000 series platform.
In enclosed non-ventilated control panels, avoid mounting this display directly above high-heat emitters such as variable frequency drives or large magnetic contactors. Maintain a minimum vertical clearance of 100 mm to ensure internal convection currents prevent the HMI's ambient operating environment from exceeding 55 degrees Celsius. Exceeding this thermal threshold accelerates the degradation of the LED backlight and can lead to display flicker.
Always route the HMI main AC power line through a dedicated isolation transformer if the facility grid experiences severe switching surges or high-frequency line noise from nearby high-frequency machinery. To prevent serial and Ethernet communication dropouts, ensure the functional ground (FG) terminal on the power supply block is connected directly to a clean Class D ground plane (100 ohms or less) using a dedicated 2 mm square or thicker ground lead.
CRITICAL WARNING:
Before initiating physical mounting or electrical terminations, ensure the primary main power breaker feeding the panel is locked and tagged out. Verify the absence of AC potential using a certified voltage tester to prevent accidental electrical shock or damage to the internal processing boards.