Mitsubishi Electric

Mitsubishi Electric HC-SFS502 HC-SFS Series AC Servo Motor

SKU HC-SFS502

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Mitsubishi Electric

  • Product No.: HC-SFS502

  • Country of origin:United States

  • Product Type: AC Servo Motors

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 480 mm x 320 mm x 320 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Optimized for high-duty cycle industrial automation systems, the Mitsubishi Electric HC-SFS502 is a high-performance AC servo motor designed to deliver precise torque and speed control within the medium-inertia, medium-capacity HC-SFS Series. Rated at 5.0 kW with a nominal speed of 2000 r/min, this industrial motor provides the mechanical stiffness and dynamic response required for heavy-duty positioning tasks. It is engineered to pair natively with the MR-J2S-500A and MR-J2S-500B servo amplifiers, ensuring seamless integration into the MELSEC control architecture and maintaining high-speed communication stability under demanding operating conditions.

Features

  • Medium Inertia Design: Highly suited for applications with fluctuating load inertias, offering stable tuning and reduced mechanical resonance.
  • High Torque Density: Delivers a rated output of 5.0 kW in a compact form factor, optimizing cabinet and machine footprint.
  • IP65 Protection Rating: Fully sealed against dust ingress and low-pressure water jets (excluding the shaft opening), ensuring reliable operation in harsh manufacturing environments.
  • Integrated Encoder Feedback: Equipped with a high-resolution absolute/incremental encoder for precise closed-loop positioning accuracy.

Applications

  • Automotive assembly line gantries and transfer systems.
  • High-speed packaging and material handling machinery.
  • Metal stamping, forming, and CNC auxiliary axes.
  • Large-scale printing presses and tension control systems.

Technical Specifications

Parameter Value / Specification
Manufacturer Mitsubishi Electric
Model Number HC-SFS502
Series Name HC-SFS Series (Medium Inertia / Medium Capacity)
Rated Output Power 5.0 kW
Rated Speed 2000 r/min
Maximum Speed 3000 r/min
Power Facility Capacity 7.5 kVA
Compatible Servo Amplifier MR-J2S-500A / MR-J2S-500B
IP Rating IP65 (excluding shaft axis)
Ambient Operating Temperature 0 to 40 degC
Shipping Weight (Calculated) 30.0 kg
Package Dimensions (Calculated) 480 mm x 320 mm x 320 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The HC-SFS502 is part of the legacy MR-J2S platform. When upgrading systems or sourcing spares, note that this motor cannot be run directly by newer MR-J3 or MR-J4 amplifiers without specific legacy emulation parameters or drive-matching modules. If transitioning to the newer HG-SR series (e.g., HG-SR502), mount geometry and connector pinouts differ; physical adapter plates and custom cable assemblies are required to adapt the legacy footprint.

Application Pitfalls & Engineering Notes

Due to the 5.0 kW power draw, regeneration energy is a critical consideration during rapid deceleration. Always calculate the thermal capacity of your external regenerative resistors connected to the MR-J2S-500A/B drive. Underestimating deceleration duty cycles can lead to overvoltage trips (Alarm 10 or Alarm 33) on the amplifier. Ensure adequate cooling clearances around the motor body, as medium-inertia motors operating in continuous-duty applications require unobstructed ambient airflow to prevent thermal runaway.

Commissioning & Wiring Tips

Always use original Mitsubishi high-flex encoder and power cables to avoid high-frequency noise interference, which can cause feedback loss (Alarm 16 or Alarm 20). Ensure that the encoder cable shield is grounded directly to the amplifier’s chassis plate. When tuning the MR-J2S amplifier, set the initial load inertia ratio manually before running auto-tuning, as the high-inertia characteristics of the HC-SFS502 can cause standard auto-tuning loops to overshoot, resulting in physical machine vibration.

Installation Guidelines

CRITICAL WARNING: HIGH VOLTAGE & RESIDUAL CHARGE

Before executing any installation, maintenance, or wiring procedures, isolate the main 3-phase AC power feeding the servo amplifier. Wait at least 20 minutes for the internal DC bus capacitors of the MR-J2S-500 amplifier to discharge fully. Verify zero-voltage state across the L+ and L- terminals with a calibrated digital multimeter before handling connections.

1
Mechanical Mounting: Secure the motor to a rigid machine frame using heavy-duty, high-tensile mounting bolts. Misalignment of the motor shaft and the driven load must be minimized to prevent premature bearing wear and shaft fracture.
2
Shaft Preparation: Apply a thin coat of anti-seize lubricant to the motor shaft. When installing pulleys or couplings, do not apply axial or radial impact forces (e.g., hitting with a hammer), as this can damage the internal high-resolution optical encoder disk.
3
Power & Feedback Connections: Securely plug in the heavy-duty power connector and encoder feedback cables. Ensure the cable strain reliefs are properly clamped so that no tension is transferred directly to the motor's internal connector housing.

FAQ

Which servo drive models are compatible with the HC-SFS502 motor?

The HC-SFS502 is designed for operation with the Mitsubishi MR-J2S-500A (Analog/Pulse) and MR-J2S-500B (SSCNET Fiber Optic) servo amplifiers.

What is the rated speed and output power of this servo motor?

The motor features a rated output power of 5.0 kW, a rated speed of 2000 r/min, and a maximum operating speed of 3000 r/min.

Can this motor be installed in wet or dusty environments?

Yes, the HC-SFS502 has an IP65 protection rating, which means it is protected against dust and low-pressure water jets. However, the shaft interface itself requires an external oil seal if exposed to continuous fluid splashing.

What causes overvoltage faults on the companion drive during deceleration?

A 5.0 kW motor generates high regenerative energy when stopping heavy loads quickly. If the drive's built-in regenerative capacity is exceeded, an external regenerative resistor must be installed to prevent overvoltage alarms.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Designing Power and Communication Redundancy

Design control-system redundancy by mapping shared dependencies, separating power and network paths, defining failover behavior, exposing degraded operation, and proof-testing every tolerated fault.

Troubleshooting Industrial Control Cabinets Systematically

A structured control-cabinet troubleshooting method covering safe work, drawings, power paths, branch protection, DC supplies, return circuits, PLC outputs, fault records and repair verification.

Measuring Voltage in Industrial Control Circuits

A practical voltage-testing guide for industrial control panels, covering reference points, meter selection, live-dead-live checks, voltage drop, ghost voltage, stored energy and intermittent faults.

Building a Verifiable Lockout Tagout Procedure

A practical lockout tagout guide covering hazardous-energy identification, isolation, stored-energy control, verification, group work, temporary testing, restoration, inspections and audits.

Designing Compressed-Air Preparation at the Machine

A field guide to point-of-use compressed-air preparation covering filters, regulators, drains, dryers, lubrication, pressure loss, isolation, monitoring, commissioning and leak testing.

Selecting Pneumatic Valve Actuation and Safe States

A practical guide to manual, pilot and solenoid pneumatic valves, covering port functions, monostable and bistable behavior, PLC outputs, safe states, commissioning and fault diagnosis.