1 of 1

Mitsubishi Electric MDS-DH-CV-370 MDS-DH Series Power Supply Unit

Mitsubishi Electric MDS-DH-CV-370 MDS-DH Series Power Supply Unit

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: MDS-DH-CV-370

  • Country of origin:United States

  • Product Type: Power Supply Units

  • Payment: T/T, Western Union

  • Weight: 12000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Power distribution within demanding multi-axis CNC machine tools is managed directly by the Mitsubishi Electric MDS-DH-CV-370, a high-capacity MDS-DH Series Power Supply Unit. Engineered for the 400V AC class architecture, this converter unit rectifies incoming 3-phase utility power into a stable DC bus voltage to feed coordinate servo drives and high-speed spindle amplifiers. With a robust 30.0kW continuous rated output and a 37.0kW 30-minute transient peak capacity, it ensures reliable energy delivery under severe dynamic loading and rapid deceleration cycles.

Key Features

  • Optimized for 400V high-voltage drive topologies, minimizing line current and wiring cross-sections.
  • Dual-rated power output structure supporting 30kW continuous operation and 37kW short-term overload demands.
  • Slim 150mm physical width profile to optimize control cabinet spatial density.
  • Regenerative power capabilities designed to feed braking energy back into the power system when used with specified line components.
  • Designed for direct coordination with dedicated AC reactors and magnetic contactors to suppress harmonic distortion and manage inrush currents.

Applications

  • Heavy-duty CNC milling and turning centers requiring synchronized multi-axis servo coordination.
  • High-speed industrial spindle drive systems with regenerative braking needs.
  • Automated automotive powertrain manufacturing cells and metal fabrication equipment.

Technical Specifications

Manufacturer Mitsubishi Electric
Model Number MDS-DH-CV-370
Series MDS-DH Series
Input Voltage Class 400V Class
Continuous Rated Output 30.0 kW
30-Minute Rated Output 37.0 kW
Power Facility Capacity 53 kVA
Unit Width 150 mm
Compatible AC Reactor DH-AL-37K
Compatible Contactor S-T65-AC400V
Compatible Circuit Protector 32 K
Net Weight 10.0 kg
Shipping Weight 12.0 kg

Connections and Interfaces

Terminal / Connector Function / Circuit Assignment
L1, L2, L3 3-Phase 400V AC Input Terminals (via AC Reactor & Magnetic Contactor)
L+, L- High-Voltage DC Bus Output to Drive Modules
CN1A / CN1B System Communication Bus Links (Daisy-chain to CNC / Drives)
PE (Ground) Protective Earth Ground Connection

Alternative Models & Compatibility

The MDS-DH-CV-370 is designed exclusively for 400V class MDS-DH systems and cannot be interchanged with 200V class MDS-D-CV systems. It requires compatible firmware integration matching the connected host CNC system (such as M700/M800 or M70/M80 controllers). When replacing older revisions, verify the total drive load matching parameters to ensure the sum of the connected servo and spindle ratings does not exceed the 53 kVA system capacity.

Application Pitfalls & Engineering Notes

Under heavy deceleration cycles of high-inertia spindle motors, the system relies on line regeneration to dissipate energy back into the network. This process absolutely requires the installation of the matching DH-AL-37K AC reactor. Omitting this reactor or substituting a generic alternative will lead to severe overvoltage (F1 ALM) errors, degradation of internal capacitor banks, and potential thermal breakdown of the input rectifying diodes.

Commissioning & Wiring Tips

Ensure that control power cable routing is physically isolated from the high-voltage DC bus (L+/L-) and AC input lines to minimize EMI noise. Connect the daisy-chained CNC communication bus using high-performance shielded cables, ensuring proper termination at both ends. Verify that the MC (Magnetic Contactor) feedback circuit is properly integrated into the emergency stop loop to safely interrupt AC supply power in the event of an internal system fault.

Installation Guidelines

CRITICAL WARNING: Hazardous voltages remain present on the high-voltage DC bus (L+/L-) and internal capacitor banks for up to 15 minutes after main AC power is disconnected. Prior to performing any wiring, inspection, or maintenance work, de-energize all power sources, wait for the physical charge LED indicator on the unit front panel to turn completely off, and verify using a calibrated voltmeter that the DC bus voltage has dropped below 50V DC.
1
Mount the MDS-DH-CV-370 vertically on a flat, vibration-free back panel, ensuring standard ventilation clearance rules are met on all sides.
2
Establish solid Protective Earth (PE) grounding directly from the module chassis to the central system ground bar.
3
Connect the 3-phase 400V AC power lines through the recommended DH-AL-37K AC reactor and S-T65-AC400V magnetic contactor.
4
Route the high-voltage DC bus links (L+ and L-) securely to adjacent servo/spindle drive modules using the original short-bar bus bridges.
5
Interface the CNC communication bus cables (CN1A/CN1B) and check terminal terminations before executing the primary system power-on sequence.
Loading product navigation…

What is the primary function of the MDS-DH-CV-370 in a CNC system?

It serves as the main AC-to-DC converter/power supply unit for 400V class multi-axis servo and spindle drive systems, rectifying incoming AC power to feed the shared high-voltage DC bus.

Is an AC reactor mandatory for operating this converter module?

Yes. Operation requires the DH-AL-37K AC reactor to suppress harmonics, protect internal rectifier circuits, and manage system impedance.

What are the continuous and peak power ratings of the MDS-DH-CV-370?

This unit is rated for 30.0 kW of continuous output power and up to 37.0 kW of transient peak output power for a maximum duration of 30 minutes.

What magnetic contactor and circuit protectors are compatible?

It is designed to coordinate directly with the S-T65-AC400V contactor and a 32 K circuit protector.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...