Description
Precise closed-loop control in automated motion applications is provided by the MR-J4-10B digital AC servo amplifier. Engineered as part of the high-performance Mitsubishi MELSERVO-J4 series, this controller delivers a rated output of 0.1 kW and operates on a 200V class supply. The unit utilizes the high-speed SSCNET III/H motion network to achieve synchronous, high-resolution communication with motion controllers and system CPUs, making it ideal for multi-axis configurations requiring strict synchronization.
This amplifier integrates advanced machine tuning features, including real-time auto-tuning, adaptive vibration suppression filters, and robust control algorithms that automatically adjust to changing mechanical loads. It supports standard rotary servo motors, linear motors, and direct drive motors while executing high-accuracy full-closed loop control via dual-wire communication interfaces. Standard safety configurations feature Safe Torque Off (STO) capability to meet stringent global machinery safety directives.
Features
- High-speed SSCNET III/H communication interface supporting cycle times down to 0.222 ms.
- Integrated Safe Torque Off (STO) function certified to SIL 3 and PL e safety standards.
- Advanced vibration suppression control II and adaptive tuning filters to minimize mechanical resonance.
- Supports full-closed loop control using high-resolution external encoders.
- Dual-channel analog monitor outputs for real-time diagnostic observation and tracking.
- Built-in dynamic brake for rapid deceleration and safety shutdown protection.
- USB interface for direct connection to PC-based setup and commissioning software.
Applications
- Semiconductor and electronics assembly machinery.
- Packaging, labeling, and food processing lines.
- Multi-axis CNC machine tools and precision metalworking equipment.
- High-speed pick-and-place robotic systems.
- Textile processing and automated industrial assembly lines.
Technical Specifications
| Manufacturer |
Mitsubishi Electric |
| Model / Part Number |
MR-J4-10B |
| Series |
MELSERVO-J4 |
| Output Power Rating |
0.1 kW |
| Output Rated Voltage |
Three-phase 170 V AC |
| Output Rated Current |
1.1 A |
| Main Circuit Power Input |
Three-phase or single-phase 200 V AC to 240 V AC, 50 Hz / 60 Hz |
| Main Circuit Rated Current |
0.9 A |
| Allowable Voltage Fluctuation |
170 V AC to 264 V AC |
| Control Circuit Power Input |
Single-phase 200 V AC to 240 V AC, 50 Hz / 60 Hz |
| Control Circuit Rated Current |
0.2 A |
| Power Consumption |
30 W |
| Control Method |
Sinusoidal PWM control, current control system |
| Communication Interface |
SSCNET III/H |
| Communication Cycle Times |
0.222 ms, 0.444 ms, 0.888 ms |
| Protection Rating |
IP20 (open, self-cooling) |
| Safety Standards |
EN ISO 13849-1 Category 3 PL e, IEC 61508 SIL 3, EN 62061 SIL CL 3, EN 61800-5-2 |
| Operating Temperature |
0 degC to 55 degC (non-freezing) |
| Storage Temperature |
-20 degC to 65 degC (non-freezing) |
| Ambient Humidity |
90% RH or less (non-condensing) |
| Vibration Resistance |
5.9 m/s2 (10 Hz to 55 Hz in X, Y, Z axes) |
| Weight |
0.8 kg |
Connections and Interfaces
| Connector Designation |
Function / Connection Type |
| CN1A |
SSCNET III/H Link Input Connection |
| CN1B |
SSCNET III/H Link Output Connection |
| CN2 |
Servo Motor Encoder Interface |
| CN3 |
Analog Monitor Output / Auxiliary Interface |
| CN5 |
USB Interface (Mini-B) for PC Configuration |
| CN8 |
Safe Torque Off (STO) Safety Signal Input |
Installation Guidelines
-
Mounting Orientation: Install the servo amplifier vertically on a flat, rigid back panel to ensure proper heat dissipation.
-
Clearance Distances: Maintain at least 10 mm clearance on both the left and right sides of the unit, and 40 mm clearance above and below for optimal airflow.
-
Grounding: Ensure a solid, low-impedance ground connection to the Protective Earth (PE) terminal. Use a dedicated ground wire to minimize electromagnetic interference (EMI).
-
Enclosure Protection: For environments with high concentrations of dust, moisture, or oil mist, install the amplifier inside a sealed electrical enclosure meeting IP54 or higher standards.
Compliance and Certifications
- CE Mark (Low Voltage and EMC Directives)
- UL Listed / cUL Listed
- TUV Certified (IEC 61508 SIL 3, EN ISO 13849-1 PL e)
- KC (Korea Certification)