1 of 1

Mitsubishi Electric QD81DL96 MELSEC-Q High-Speed Data Logger Unit

Mitsubishi Electric QD81DL96 MELSEC-Q High-Speed Data Logger Unit

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: QD81DL96

  • Country of origin:United States

  • Product Type: High-Speed Data Logger Units

  • Payment: T/T, Western Union

  • Weight: 150g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Directly interfacing with the system backplane, the Mitsubishi Electric QD81DL96 high-speed data logger unit provides robust data logging capabilities for MELSEC-Q series PLC platforms. This module eliminates the need for dedicated personal computers or complex SCADA-based logging applications by recording system variables directly to localized memory media. Designed for precision diagnostics and predictive maintenance, the unit accesses and logs data from up to 64 connected CPUs in a multi-CPU configuration, matching sequence scan cycles with microsecond-level synchronization.

The QD81DL96 supports dual collection methodologies: high-speed trigger logging for transient events, and general-purpose continuous logging for historical trend analysis. Utilizing industry-standard file formats such as CSV, BIN, and Excel-compatible files, this module ensures that logged data is readily accessible by analytical packages, database engines, and supervisory control systems. Automated data transfer is facilitated through integrated FTP client/server protocols and email notification functions over a standard 100 Mbps Ethernet connection.

Features

  • Multi-CPU Integration: Accesses up to 64 CPUs simultaneously across the controller backplane.
  • Synchronized High-Speed Collection: Enables sequence scan time synchronization with collection intervals as fast as 1 ms for trigger logging and 3 ms for continuous logging.
  • Dual Logging Profiles: Offers both continuous and trigger-based data capture with configurable pre-trigger and post-trigger boundaries.
  • Direct Excel Report Generation: Automatically formats collected data into standard xls files directly on the local module.
  • Advanced Notification & Transfer: Embedded FTP client/server and SMTP capabilities allow automatic transmission of logged files to central servers and automated event notification emails.
  • Robust Storage Support: Features an integrated slot for industrial-grade CompactFlash (Type I) cards.

Applications

  • Traceability and quality assurance in high-speed manufacturing lines.
  • Transient fault analysis and sequence of events (SOE) recording in power distribution.
  • Long-term environmental and process variable trend monitoring in water treatment plants.
  • Equipment performance tracking and predictive maintenance in heavy machining.

Technical Specifications

Manufacturer Mitsubishi Electric
Part Number / Model QD81DL96
Series MELSEC-Q Series
Module Type High-speed data logger unit
Network Interface 10BASE-T / 100BASE-TX (RJ45)
Communication Mode Full duplex / Half duplex (with Auto-negotiation)
Storage Media Slot CompactFlash Card Type I (3.3 V DC, Max. 150 mA)
Occupied I/O Points 32 points (Intelligent function module)
Maximum CPUs Accessed Up to 64 CPUs
Logging Data Formats CSV, BIN, XLS (Excel)
Email Authentication No authentication, SMTP, AUTH (PLAIN, LOGIN, CRAM-MD5), POP before SMTP
Internal Current Consumption (5 V DC) 0.50 A
Height 98 mm
Width 27.4 mm
Depth 90 mm
Weight 0.15 kg

Connections and Interfaces

Interface Port Function Description
RJ45 Port Ethernet connection for FTP client/server communication, SMTP email transfer, and configuration utility interfacing.
CF Card Slot Dedicated Type I CompactFlash slot for industrial memory cards containing configuration data, system logs, recipes, and Excel reports.

Installation Guidelines

  • Backplane Insertion: Turn off the main rack power supply before inserting or removing the module from the Q-series base unit.
  • CompactFlash Handling: Format the CF card using the correct FAT file system before operation. Do not eject the card while the access LED is illuminated.
  • Shielding and Grounding: Use category 5 (or higher) shielded twisted pair (STP) cables for high-noise industrial environments to avoid signal loss or log interruption.
  • Ventilation: Ensure at least 30 mm of clearance above and below the base unit for proper heat dissipation.

What memory card standard does the QD81DL96 support?

The module is designed with a dedicated slot for a Type I CompactFlash (CF) card, operating at 3.3V with a maximum supply power capacity of 150 mA.

Can the QD81DL96 access data from multiple CPUs in a single chassis?

Yes, it can access device memory and registers across up to 64 different CPUs in a multi-CPU system configuration.

What is the fastest data collection interval supported by this logger?

For trigger logging, the module supports sequence scan time synchronization down to a collection interval of 1 ms to 32767 ms. Continuous logging supports intervals from 3 ms to 32767 ms.

What file output formats does the QD81DL96 generate?

It can save data in CSV (.CSV) or Binary (.BIN) format for standard logging, and can output layout files in Excel (.XLS) format for report generation.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...