Description
Engineered to power CQM1-series programmable controllers, the Omron CQM1-PA216 delivers reliable, regulated power to the system backplane and associated modules. This modular power supply unit accepts selectable AC input voltages, generating both 5 VDC logic power for internal CPU circuitry and 24 VDC auxiliary power for external sensor or output interfaces. With a total integrated power capacity of 30 W, the CQM1-PA216 manages complex dynamic loads while maintaining system stability and protecting internal components from line-voltage fluctuations and transient electrical noise.
Features
- Flexible AC input configuration with selectable 100 VAC or 230 VAC operating modes.
- Dual DC output rails providing 5 VDC at 6.0 A and 24 VDC at 0.5 A.
- High-capacity noise immunity of 1500 Vp-p to isolate control logic from industrial grid interference.
- Robust inrush current protection limiting peak startup current to 30 A.
- Compact, screw-terminal interface designed for rapid field wiring and secure connection retention.
Applications
- Factory automation and legacy machine tool control panels.
- Material handling and packaging conveyor line synchronization.
- Pumping stations and local water treatment telemetry systems.
- Automotive subsystem assembly lines requiring local PLC deployment.
Technical Specifications
| Manufacturer |
Omron |
| Part Number / Model |
CQM1-PA216 |
| Product Type |
Power Supply Unit |
| Supply Voltage |
100 or 230 VAC (selectable), 50/60 Hz |
| Operating Voltage Range |
85 to 132 VAC or 170 to 264 VAC |
| Operating Frequency Range |
47 to 63 Hz |
| Power Consumption |
120 VA max. |
| Inrush Current |
30 A max. |
| Output Capacity |
5 VDC: 6.0 A; 24 VDC: 0.5 A (30 W total combined) |
| Insulation Resistance |
20 MOhm min. (at 500 VDC) between AC external terminals and GR terminals |
| Noise Immunity |
1,500 Vp-p, pulse width: 100 ns to 1 microsecond, rise time: 1 ns |
| Shock Resistance |
147 m/s2, 3 times each in X, Y, and Z directions |
| Operating Temperature |
0 to 55 degC |
| Storage Temperature |
-20 to 75 degC (excluding battery) |
| Humidity |
10% to 90% (with no condensation) |
| Atmosphere |
Must be free from corrosive gases |
| Grounding Resistance |
Less than 100 Ohm |
| Enclosure Rating |
Mounted in a panel |
Connections and Interfaces
| Terminal Label |
Function Description |
| L1 / L2 (AC Input) |
Line and neutral input terminals for AC power distribution |
| GR |
Ground terminal (grounding resistance of less than 100 Ohm required) |
| 24 VDC Output |
Auxiliary output terminals for loop transmitters, sensors, or simple relay coils |
Installation Guidelines
-
Voltage Selection: Always verify that the input voltage selection matches local supply levels before applying power to avoid unit damage.
-
Thermal Considerations: Install the power supply in a standard vertical orientation on the PLC backplane to allow adequate heat dissipation. Maintain a minimum clear distance of 50 mm above and below the assembly.
-
Grounding: Connect the GR terminal directly to a dedicated ground point using a thick-gauge wire to maximize noise suppression and guarantee electrical safety.
-
Load Planning: Verify that the total dynamic current consumption of the CPU unit and all connected I/O modules on the rack does not exceed the combined 30 W limit.