Omron

Omron CS1W-AD161 CS Series Analog Input Unit

SKU CS1W-AD161

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Omron

  • Product No.: CS1W-AD161

  • Country of origin:Japan

  • Product Type: Analog Input Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Engineered for high-density analog signal acquisition within industrial automation environments, the CS1W-AD161 serves as a high-performance analog input module for Omron CS-series PLC systems. This module enables direct connection to various sensors and transmitters, translating physical process variables into precise digital values for the CPU unit.

With support for up to 16 input channels, this unit minimizes backplane footprint while maximizing input capacity. The module accommodates multiple voltage and current range configurations, making it highly adaptable for diverse industrial applications including process control, environmental monitoring, and factory automation.

Features

  • Supports 16 high-density analog inputs in a single slot.
  • Independently configurable input ranges per channel for voltage or current signals.
  • Utilizes a robust MIL connector interface for secure, high-density field wiring.
  • Fast analog-to-digital conversion rate for real-time process monitoring.
  • Direct integration with Omron CS-series PLC backplanes.

Applications

  • Process control systems (flow, pressure, and level monitoring)
  • Water and wastewater treatment facilities
  • Power generation and utility automation
  • Thermal processing and oven control

Technical Specifications

ManufacturerModel/Part NumberSeriesModule TypeNumber of InputsInput Signal RangesExternal ConnectionCurrent Consumption (5 VDC)
Omron
CS1W-AD161
CS Series
Analog Input Unit
16
1 to 5 V, 0 to 5 V, 0 to 10 V, -10 V to 10 V, 4 to 20 mA
MIL connector
0.15 A

Installation Guidelines

  • Always ensure the PLC rack power supply is turned off before mounting or removing the module.
  • Use shielded twisted-pair (STP) cables for all analog input connections to mitigate electromagnetic interference.
  • Ground the cable shields at a single point (typically at the PLC side) to prevent ground loops.
  • Route low-voltage analog signal cables separately from high-voltage AC power lines.

Compliance and Certifications

  • CE Compliant
  • UL Listed

FAQ

How many analog inputs does the CS1W-AD161 support?

The CS1W-AD161 analog input module supports up to 16 individual input channels.

What input signal types are compatible with the CS1W-AD161?

It supports voltage inputs (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 V to 10 V) and current inputs (4 to 20 mA).

What type of connector is used for field wiring on this module?

The module uses a high-density MIL connector for external field connections.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Technical knowledge

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.