First TwinCAT PLC Project on a Beckhoff IPC
Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.
Manufacturer: Omron
Product No.: DRT2-ID16
Country of origin:Japan
Product Type: Transistor Remote I/O Terminals
Payment: T/T, Western Union
Weight: 1500g
Shipping port: Xiamen
Warranty: 12 months
Executing digital signal collection within industrial fieldbus architectures, the Omron DRT2-ID16 operates as a high-density remote digital input module designed for seamless integration into DeviceNet network architectures. This terminal block features 16 NPN inputs with a shared positive common, streamlining the routing of field sensor wires directly to centralized controllers without complex local distribution wiring.
| Manufacturer | Omron |
| Model Number | DRT2-ID16 |
| Product Type | Transistor Remote I/O Terminal |
| Communication Protocol | DeviceNet |
| Input Specifications | 16 points, NPN (+ common) |
| Wiring Connection | M3 Screw terminals |
| Internal Circuit Power | Supplied from DeviceNet network connector |
| Rated I/O Power Supply | 24 VDC |
| Operating Temperature | -10 to 55 degC |
| Storage Temperature | -25 to 65 degC |
| Ambient Humidity | 25% to 85% (non-condensing) |
| Unit Weight | 0.14 kg |
| Shipping Weight (Calculated) | 0.35 kg |
The DRT2-ID16 represents standard NPN logic remote I/O within the Omron DeviceNet family. For installations requiring PNP sensor interfaces, evaluate the counterpart model DRT2-ID16-1, which utilizes positive-logic (- common) input circuitry. These modules share identical physical dimensions and mounting footprint for ease of hardware swaps during control cabinet modifications.
Ensure complete compliance with the physical layout requirements of the DeviceNet network. Do not exceed maximum bus length recommendations. To limit signal reflections and packet degradation, verify that a 121-ohm terminating resistor is installed on both physical ends of the trunk line. Ensure the external I/O power supply remains separate from the network communication power line to maintain electrical isolation boundaries.
The node address must be set using the physical rotary switches on the module face. Always isolate power before making changes to these rotary switches, as new node address configurations will not take effect dynamically until a full hardware power cycle occurs.
Global Express Shipping
Returns & Warranty

Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
Japan
|