Electromagnetic Induction in Industrial Coils
Understand how industrial coils create magnetic force, induce voltage, generate switching transients, and fail in relays, solenoids, transformers, motors, and proximity sensors. in service.
Manufacturer: Omron
Product No.: E5CZ-Q2MT AC100-240
Country of origin:Japan
Product Type: Digital Temperature Controllers
Payment: T/T, Western Union
Weight: 500g
Dimensions: 48 x 48 x 85 mm
Shipping port: Xiamen
Warranty: 12 months
For critical thermal regulation loops, the Omron E5CZ-Q2MT AC100-240 process controller provides high-accuracy PID control within a standard 1/16 DIN footprint. Built with a highly responsive 150 ms sampling period, this multi-input unit supports a wide array of temperature sensors and analog inputs, delivering stable control outputs for demanding industrial thermal processes. Equipped with a 12 VDC voltage output, it is engineered specifically to cycle external solid-state relays (SSRs) with minimal switching latency, while its dual auxiliary outputs allow for independent alarm configuration and system protection loops.
| Specification Parameter | Technical Value |
|---|---|
| Power Supply Voltage | 100 to 240 VAC, 50/60 Hz |
| Operating Voltage Range | 85% to 110% of rated voltage |
| Power Consumption | 6.0 VA maximum |
| Sensor Inputs (Multi-Input) | Thermocouple (K, J, T, E, L, U, N, R, S, B, W, PL II), Platinum RTD (Pt100, JPt100), Analog Current/Voltage |
| Control Output (Voltage) | 12 VDC, 21 mA (with short-circuit protection) |
| Auxiliary Outputs | 2 SPST-NO relay outputs (250 VAC, 1 A resistive load) |
| Control Method | 2-PID control (with auto-tuning) or ON/OFF control |
| Sampling Period | 150 ms |
| Enclosure Rating | Front Panel: IP66, Rear Case: IP20, Terminals: IP00 |
| Ambient Operating Temperature | -10 to 55 degC (no condensation or icing) |
| Manufacturer | Omron Corporation |
| Country of Origin | Japan |
| Shipping Weight (Calculated) | 0.15 kg |
| Package Dimensions (Calculated) | 48 x 48 x 85 mm |
The E5CZ series represents a critical historical bridge in Omron's temperature controller catalog. While physical dimensions match the older E5CN generation, verify terminal numbers prior to swap-outs because terminal configurations vary between generations. For modern deployments requiring even faster loop responses (50 ms) and larger display configurations, consider upgrading to the E5CC-QX2DSM-800 series.
When utilizing the 12 VDC voltage output to drive multiple external solid-state relays in parallel, verify that the total switching current does not exceed the internal 21 mA current limit. Exceeding this rating will cause the voltage output to drop below the minimum SSR trigger threshold, resulting in unstable heating loops and potential controller damage. Always maintain a separate physical run for high-voltage element power lines and low-voltage controller input cables to avoid EMI-induced measurement drift.
When running auto-tuning routines for the first time, allow the thermal system to reach standard ambient conditions first. Initiating auto-tuning on an already hot system will calculate incorrect derivative and integral constants, resulting in excessive process value overshoot during normal operation. If using thermocouple sensors, only use correct compensation cables directly to the terminal block to prevent cold junction compensation reference errors.
Isolate and verify the de-energization of all power supply and auxiliary circuit loops prior to terminal installation or module extraction. Failure to de-energize primary AC lines can result in severe electrical shock, system circuit damage, or hazardous false triggers on connected heating elements.
Global Express Shipping
Returns & Warranty

Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
Japan
|