Omron

Omron H7CX-A4S-N H7CX Series Multifunction Counter/Tachometer

SKU H7CX-A4S-N

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Omron

  • Product No.: H7CX-A4S-N

  • Country of origin:Japan

  • Product Type: Multifunction Counter/Tachometers

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 4.8 cm x 8.4 cm x 4.8 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Optimized for dynamic process monitoring, the Omron H7CX-A4S-N acts as a highly reliable industrial counting and rate-measurement module within a standard DIN-sized footprint. This 4-digit, single-stage configuration device serves dual functions as a digital counter and high-speed tachometer, making it ideal for tracking cycles, batch quantities, and rotational velocities. Equipped with screw terminals and a fast-acting transistor output, the unit integrates smoothly into low-latency control loops driven by PLCs or supervisory relays. The integrated power supply accepts universal AC voltage, mitigating the need for external step-down transformers in standard control panels.

Features

  • Dual-function layout operational as either an advanced digital counter or precise tachometer.
  • High-visibility 4-digit display featuring dynamic, custom-configurable color-changing status backlighting.
  • Single-stage preset control providing rapid trigger capability upon reaching target setpoints.
  • Solid-state transistor output designed for high-frequency switching operations and spark-free output logic.
  • Universal wide-range AC power input supporting global electrical standards.
  • Robust rear-facing screw terminals ensuring secure physical connections under structural vibration.

Applications

  • High-speed industrial packaging line batch counting and piece tracking.
  • Rotational velocity (RPM) measurement and slip detection on heavy conveyor systems.
  • Precision length-cutting operations using quadrature encoder input setups.
  • Stamping and cycle-limit monitoring for automated metal fabrication machinery.

Technical Specifications Table

Parameter Value
Manufacturer Omron
Model Reference H7CX-A4S-N
Device Type Multifunction Counter / Tachometer
Display Digits 4 digits (-999 to 9999)
Supply Voltage 100 to 240 VAC at 50/60 Hz
Preset Stages 1-stage preset
Output Type Transistor output (NPN/PNP selectable)
Connection Method Rear screw terminal block
Front Panel Dimensions 48 mm x 48 mm (1/16 DIN)
Insertion Depth 84 mm
External Sensor Power 12 VDC (up to 100 mA)
Shipping Weight (Calculated) 0.35 kg

Connections and Interfaces

Terminal Function Description
1 AC Power Supply Input (Line)
2 AC Power Supply Input (Neutral)
3 Sensor Power Supply Output (+12 VDC)
4 Signal Input A (Count / Tachometer Pulse Input)
5 Signal Input B (Directional Count Control)
6 Reset Input Signal (External Counter Clear)
7 Key Protect Input (Locks Front Panel Parameters)
8 Output Common Ground (0V Reference)
9 Transistor Output (Collector)

Empirical Engineering Insights

Alternative Models & Compatibility

The updated "N" suffix denotes a modernized internal processor design complying with recent RoHS directive updates and enhanced display contrast. The H7CX-A4S-N serves as a direct drop-in replacement for the legacy H7CX-A4S model. When replacing older non-N versions, verify parameter compatibility, as default gate time and input speed profiles may require brief adjustment in the configuration utility menu.

Application Pitfalls & Engineering Notes

When using this module in tachometer mode, avoid routing high-voltage motor lead lines in parallel with the sensor inputs. If physical relay or microswitch contacts are used for inputs instead of proximity sensors, set the maximum input speed setting to 30 Hz via the internal menu. Setting this parameter to 5 kHz or 10 kHz with physical contacts will result in count tracking errors caused by mechanical switch bounce.

Commissioning & Wiring Tips

Always utilize shielded twisted-pair cabling for the sensor inputs (Input A and Input B). To prevent ground loops from injecting electrical noise into the counter's internal processor, ground the cable shield strictly at the single point panel ground instead of tying it back to Terminal 8 (Common).

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all upstream electrical power sources supplying the 100-240 VAC feed lines prior to initiating any installation, modification, or wiring operations. Failure to verify zero-energy states on these contacts presents a severe electrical shock hazard and can cause complete structural destruction of the internal control components.

1
Mount the counter into a standard 45 mm x 45 mm DIN panel cutout, securing the device housing from behind using the native mounting adapter bracket.
2
Route input signals separate from power lines and wire input sensors to Terminals 4 and 5 according to either NPN or PNP operational rules.
3
Connect the transistor output load to Terminals 8 and 9, keeping current load draw below the standard rating to prevent overheating the output stage.
4
Terminate the main 100 to 240 VAC power source wires to Terminals 1 and 2, recheck all structural terminal tightening torques, and energize the system.

FAQ

Can the H7CX-A4S-N operate with PNP proximity sensors?

Yes, the input mode can be configured via the internal parameter menu to accommodate both NPN and PNP sensor types.

What is the function of Key Protect on Terminal 7?

When Terminal 7 is connected to common, it locks the front panel button controls to prevent operators from accidentally modifying preset targets or operational parameters.

How do I switch the H7CX-A4S-N between counter and tachometer modes?

Operational modes are selected by adjusting the internal DIP switch settings on the side of the unit or by accessing the functional parameters through the front-panel menu program.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.