Description
Integrating logic, motion control, and database connectivity into a compact form factor, the Omron NX1P2-1040DT1 serves as a core controller within the Sysmac automation platform. Designed for small-to-medium machine automation, this Sysmac NX1P CPU provides synchronized control of all machine devices, including motion, I/O, safety, and vision. It features built-in dual industrial network ports to enable seamless vertical and horizontal integration across factory environments, ensuring reliable execution of synchronized motion control and high-speed data acquisition.
Features
- Synchronized control of motion, I/O, and safety networks under a single unified controller.
- Built-in EtherCAT master port and EtherNet/IP port for high-speed device networks and plant-level communications.
- Support for up to 4 synchronized motion control axes.
- Expandable local I/O capacity using NX-series digital, analog, and communication modules.
- Up to 1.5 MB of program memory and 2 MB of variables memory to accommodate complex logic operations.
- Secure execution with comprehensive user access management and program copy-protection.
Applications
- Packaging machinery and labeling systems.
- Material handling and conveyor sorting networks.
- Pick-and-place assembly stations.
- Automated pharmaceutical dispensing and packaging.
- Food processing manufacturing cells.
Technical Specifications
| Manufacturer |
Omron |
| Part Number/Model |
NX1P2-1040DT1 |
| Controller Family |
Sysmac NX1P Series |
| Primary Task Cycle Time |
2 ms |
| Program Memory |
1.5 MB |
| Variables Memory |
2 MB |
| Communication Interfaces |
EtherCAT Master, EtherNet/IP, Ethernet TCP/IP |
| Supply Voltage |
20.4 to 28.8 VDC |
| Dimensions (W x H x D) |
14.8 cm x 10.0 cm x 7.1 cm |
| Weight |
0.66 kg |
Connections and Interfaces
| Interface Type |
Function / Description |
| EtherCAT Port |
RJ45 connector, functions as Master for servo drives, variable speed drives, and remote I/O terminal couplers. |
| EtherNet/IP Port |
RJ45 connector, supports peer-to-peer tag data links, HMI communications, and standard TCP/IP socket connections. |
| Power Terminals |
Push-in Plus terminal block for 24 VDC control power input. |
| Built-in I/O Terminals |
High-speed solid-state digital inputs and outputs for direct field device connection. |
Installation Guidelines
-
Mounting: Mount horizontally on a standard 35 mm DIN rail inside an enclosed electrical cabinet.
-
Ventilation: Ensure at least 30 mm of clearance above and below the module to maintain natural convection airflow.
-
Wiring: Use shielded twisted-pair (STP) Category 5e or higher cables for industrial Ethernet networks to prevent electromagnetic interference.
-
Grounding: Connect the functional ground terminal to a low-impedance ground (100 ohms or less) using a dedicated wire.
Compliance and Certifications
- CE Compliant
- cULus Listed
- KC (Korean Communications Commission)