Omron

Omron V680-HA63B V680 Series RFID Amplifier Unit

SKU V680-HA63B

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Omron

  • Product No.: V680-HA63B

  • Country of origin:Japan

  • Product Type: RFID Amplifier Units

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed for high-performance industrial RFID tracking, the Omron V680-HA63B serves as a dedicated RFID Amplifier Unit within the V680 series ecosystem. This module bridges the physical read/write antennas with upstream ID controllers, ensuring reliable signal transmission and high-speed data processing. It is engineered to interface seamlessly with both 2-kbyte and 8-kbyte memory tags, making it a highly adaptable component for tracking, sorting, and positioning applications in demanding industrial environments.

Features

  • Dual-Memory Support: Fully compatible with both 2-kbyte and 8-kbyte high-capacity FRAM/EEPROM RFID tags.
  • Robust Environmental Protection: IP67/IP65 rated outer housing ensures total resistance to dust and low-pressure water jets, ideal for harsh production floors.
  • High-Speed Signal Processing: Minimizes read/write cycle latency to optimize conveyor speeds and throughput rates.
  • Flexible Antenna Integration: Interfaces with V680-HS series read/write antennas through dedicated industrial connectors.
  • Compact Form Factor: Small footprint designed for simple DIN-rail or panel mounting inside local junction boxes.

Applications

  • Automotive powertrain assembly and body-in-white tracking lines.
  • Automated pallet routing and sorting systems in logistics hubs.
  • Work-in-progress (WIP) tracking in pharmaceutical and food processing facilities.
  • Tooling identification and status monitoring on CNC machining centers.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number V680-HA63B
Product Type RFID Amplifier Unit
Compatible Memory Capacities 2-kbyte, 8-kbyte
Degree of Protection IP67/IP65 (IEC 60529)
Ambient Operating Temperature -10 to 55 degC (with no icing)
Ambient Storage Temperature -25 to 65 degC (with no icing)
Net Weight 0.65 kg
Shipping Weight (Calculated) 2.0 kg

Alternative Models & Compatibility

The V680-HA63B is part of the modular V680 series. It is designed to work exclusively with V680-HS series Read/Write Antennas (such as V680-HS52 or V680-HS63) and V680-CA5D01-V2 / CS1W-V680C11 Controllers. Do not attempt to pair this unit with newer V680S series integrated reader/writers, as they utilize completely different physical layer and protocol specifications.

Application Pitfalls & Engineering Notes

To prevent read/write errors caused by electromagnetic interference (EMI), keep all antenna and amplifier cabling separated from high-voltage lines, servo motor cables, and variable frequency drives (VFDs) by a minimum of 200 mm. Avoid mounting the amplifier directly onto highly vibrating metal frames without vibration-damping mounts, as sustained harmonic resonance can stress internal PCB joints over time.

Commissioning & Wiring Tips

Always use the proprietary shielded cables supplied by Omron for antenna-to-amplifier connections. Ensure that the ground terminal (FG) of the connected ID controller is tied to an independent Class D ground (grounding resistance of 100 ohms or less). When configuring system parameters in your PLC, match the controller transmission speed settings with the selected tag type to prevent communications timeout faults (E70/E72).

Installation Guidelines

CRITICAL WARNING

Always completely isolate the main power source before mounting, wiring, or servicing the V680-HA63B. Connecting or disconnecting the antenna or controller cables while the system is energized may cause catastrophic dielectric breakdown of the amplifier's internal RF circuitry.

1

Mount the amplifier unit securely onto a standard 35 mm DIN rail or directly to a flat panel using the integrated mounting brackets.

2

Connect the compatible V680-HS series Read/Write Antenna to the designated port, ensuring the locking collar is fully threaded and sealed to maintain the IP rating.

3

Run the controller connection cable to the ID Controller unit, observing minimum bend radius limitations and keeping distance from electromagnetic noise sources.

4

Apply power to the ID Controller and verify that the amplifier's status indicator LEDs align with normal operational parameters.

FAQ

Which RFID tags are compatible with the V680-HA63B?

This amplifier unit is fully compatible with both 2-kbyte and 8-kbyte memory RFID tags within the Omron V680 product range, supporting standard FRAM and EEPROM variants.

What is the ingress protection rating of this module?

The module features an IP67/IP65 (IEC 60529) ingress protection rating, making it highly resistant to dust and water ingress in demanding industrial environments.

Can I hot-swap the antenna cable while the amplifier is powered?

No. You must completely de-energize the connected ID controller before plugging or unplugging the antenna cable to prevent permanent electrical damage to the RF transceiver stage.

What are the grounding requirements for this RFID system?

To prevent communication errors from electrical noise, the system must be grounded via a dedicated Class D ground with a grounding resistance of 100 ohms or less connected to the controller.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Technical knowledge

1746-A7 Chassis Replacement Checks: Slots, Power and Interconnects

An engineering checklist for replacing an Allen-Bradley 1746-A7: verify chassis series, backplane loading, slot plan, interconnect cables, mounting, grounding and receiving condition.

IC200MDL650 Replacement Checks: Logic Polarity, Filters, and Commons

A field replacement guide for GE Fanuc IC200MDL650 covering revision-dependent negative logic, four common groups, 24 VDC thresholds, input filtering, carrier checks and commissioning records.

IC697CPX935 Replacement Checks: Memory, Ports, and Rack Power

A field-focused IC697CPX935 replacement guide covering fast memory, firmware-dependent serial behavior, rack power, cooling, I/O architecture and backup records.

IC693DSM324 Replacement Checks: FSSB, Firmware and Follower Control

A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.

HIMA F3430 Replacement Checks: Contact Ratings and Safety Limits

A field-focused HIMA F3430 replacement guide covering relay contact ratings, DC load derating, fusing, F3330/F3331 differences, safety restrictions and commissioning records.

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits

A field-focused IC697PWR710 replacement guide covering 5 V load calculations, dual-rack limits, extension cables, input checks, protection behavior and hardware revision risks.