Description
Precision dimensional measurement and positioning are highly optimized using the Omron ZX-LT005 through-beam laser sensor head. Operating within the high-performance ZX series platform, this optical micrometer head utilizes a visible-light semiconductor laser transmitter paired with a dedicated receiver to establish a highly focused measuring field. This configuration enables exceptional sensitivity for detecting minute components, measuring outer diameters, and managing material edges in automated assembly and inspection processes.
Engineered for high-speed industrial lines, the ZX-LT005 sensor head delivers a consistent 5 mm measurement width with minimal deviation under varying environmental conditions. Its rugged structural design features a polyetherimide case and high-quality glass optical covers, ensuring optical alignment and mechanical stability over extended cycles of continuous operation.
Features
- Utilizes a high-precision visible-light semiconductor laser light source with a 650 nm wavelength.
- Laser safety standard compliant with JIS Class 1 guidelines, ensuring a safe working environment under standard operation.
- Provides a flat 5 mm measurement width for highly accurate edge detection, diameter verification, and gap width analysis.
- Supplied with a robust connector relay and a standard 500 mm connection cable.
- Compatible with dedicated extension cables to extend the functional transmission range up to 10 meters.
- High thermal stability with a low temperature characteristic of only 0.2% FS/degC.
Applications
- In-line outer diameter measurement of wires, tubes, and medical-grade piping.
- High-speed edge control and tracking in continuous film web guiding systems.
- Precise dimensioning, verification, and positioning of electronic components and semiconductor lead frames.
- Gap and slot dimension checking on precision CNC machined metal components.
Technical Specifications
Manufacturer
| Omron |
Part Number / Model
| ZX-LT005 |
Series
| ZX Series |
Optical System
| Through-beam micrometer type |
Light Source
| Visible-light semiconductor laser (wavelength: 650 nm) |
Laser Classification
| JIS Class 1 |
Maximum Output Power
| 0.35 mW max. |
Measurement Width
| 5 mm |
Temperature Characteristic
| 0.2% FS/degC |
Ambient Illumination
| Incandescent lamp: 10,000 lx max. (on light-receiving side) |
Ambient Operating Temperature
| 0 to 50 degC (with no icing or condensation) |
Ambient Storage Temperature
| -25 to 70 degC (with no icing or condensation) |
Degree of Protection
| IEC 60529 IP40 |
Connection Method
| Connector relay (standard cable length: 500 mm) |
Maximum Extension Length
| Extendable up to 10 m using dedicated extension cables |
Housing Material
| Polyetherimide (Case), Polycarbonate (Case cover), Glass (Unit cover) |
Weight
| Approx. 0.22 kg |
Connections and Interfaces
| Interface Type |
Specification / Function |
| Integrated Cable |
500 mm flexible cable with quick-disconnect connector relay |
| Extension Support |
Accepts specialized low-attenuation extension cables up to 10 meters |
| Receiver Connection |
Direct plug-in coupling to the corresponding ZX series amplifier unit |
Installation Guidelines
-
Optical Alignment: Ensure the transmitter head and receiver head are rigidly mounted and parallel. Any angular misalignment will directly affect measurement accuracy and system linearity.
-
Cleaning: Keep the optical glass covers free from dust, oil, and moisture. Clean only with non-abrasive optical cloth and isopropyl alcohol if required.
-
Wiring: Route the sensor cable separately from high-voltage electrical lines or frequency inverter power lines to eliminate the risk of electromagnetic interference.
-
Environmental Conditions: Do not install in environments subject to direct water spray or high humidity that could lead to condensation on the optical lenses.
Compliance and Certifications
- JIS Class 1 Laser Product
- IEC 60825-1 Class 1 Compliant
- CE Mark Compliant (when integrated with compliant ZX-series amplifier units)