Description

The Pepperl+Fuchs KCD2-SOT-Ex1.LB is a 1-channel isolated barrier designed for intrinsic safety applications to transfer digital signals from hazardous areas to safe areas. This device features a single field-side digital input that controls two passive transistor outputs on the control side. Configurable via DIP switches, the unit can function as a signal splitter (1 input and 2 outputs) or assign its second transistor output as an error indicator. The KCD2-SOT-Ex1.LB switch amplifier supports line fault detection (LFD) for monitoring lead breakage and short circuits, and processes signals from dry contacts or NAMUR sensors according to EN 60947-5-6.

Features

  • 1-channel isolated barrier for intrinsic safety applications
  • 24 V DC supply via removable screw terminals or Power Rail
  • Dry contact or NAMUR sensor input
  • 2 passive transistor outputs with reversible mode of operation
  • Usable as a signal splitter (1 input to 2 outputs)
  • Line fault detection (LFD) for lead breakage and short-circuit monitoring
  • Collective error message output via Power Rail
  • Front-accessible DIP switches for operational mode and fault detection configuration
  • Compact 12.5 mm housing width for DIN mounting rail installation
  • Up to SIL 2 (SC 3) safety evaluation according to IEC/EN 61508

Applications

  • Intrinsic safety signal isolation and processing in hazardous areas
  • Signal splitting from a single field sensor to multiple control devices
  • Interface conversion for NAMUR proximity sensors and discrete dry contact switches
  • Status monitoring and line fault detection in DCS, SIS, and PLC automation loops

Technical Specifications

Parameter Specification
Manufacturer Pepperl+Fuchs
Model KCD2-SOT-Ex1.LB
Order Number 214240
Signal Type Digital Input
Safety Integrity Level (SIL) SIL 2 (Systematic Capability SC 3)
Rated Voltage (Ur) 19 ... 30 V DC
Ripple <= 10%
Rated Current (Ir) 20 ... 15 mA
Power Dissipation <= 700 mW
Field Side Input Terminals 1+, 2- (NAMUR acc. to EN 60947-5-6)
Open Circuit Voltage / Short-Circuit Current approx. 10 V DC / approx. 8 mA
Switching Point / Hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA
Line Fault Detection Breakage I <= 0.1 mA, Short-circuit I >= 6.5 mA
Pulse / Pause Ratio min. 100 us / min. 100 us
Control Side Output Output I: terminals 5+, 6-; Output II: terminals 7+, 8-
Output Type Passive Transistor
Output Rated Voltage (Ur) 30 V DC
Output Rated Current 50 mA
Response Time <= 200 us
Signal Level 1-signal: (external voltage) - 3 V max. for 50 mA; 0-signal: off-state current <= 10 uA
Switching Frequency <= 5 kHz
Galvanic Isolation (Input/Output, Input/Power) Reinforced insulation acc. to EN 50178, rated voltage 300 Veff
Galvanic Isolation (Output/Power, Output/Output) Basic insulation acc. to EN 50178, rated voltage 50 Veff
Safe Electrical Isolation (Hazardous to Safe) Acc. to IEC/EN 60079-11, voltage peak value 375 V
Ambient Temperature -20 ... 60 degC (-4 ... 140 degF), extended up to 70 degC (158 degF)
Degree of Protection IP20
Mounting On 35 mm DIN mounting rail acc. to EN 60715:2001
Connection Type Screw terminals
Mass approx. 100 g
Dimensions (W x H x D) 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch), housing type A2

Connections/Interfaces

Connector Pin Function
1+ Field Input + (Hazardous Area)
2- Field Input - (Hazardous Area)
5+ Output I Transistor +
6- Output I Transistor -
7+ Output II Transistor +
8- Output II Transistor -
9+ Supply Voltage 24 V DC +
10- Supply Voltage 24 V DC -
Power Rail Supply Voltage 24 V DC / Collective Error Output

Installation Guidelines

  • DIN Rail Mounting: Snap the module onto a 35 mm DIN mounting rail complying with EN 60715:2001.
  • Wiring Requirements: Connect hazardous area field wiring to the top blue removable terminal block (terminals 1+, 2-). Connect safe area output and power wiring to the bottom green removable terminal blocks.
  • Power Supply: Supply 19 ... 30 V DC via screw terminals 9+ and 10- or directly through the Power Rail system.
  • Configuration: Set front DIP switches (S1, S2, S3) to select output active mode, assign output II function, and enable or disable line fault detection.
  • Hazardous Area Precautions: Ensure intrinsic safety parameters (Uo = 10.5 V, Io = 17.1 mA, Po = 45 mW) match field device specifications and maximum safe voltage (Um = 253 V AC) limits are respected.

Compliance and Certifications

  • Safety Integrity Level: SIL 2, Systematic Capability SC 3 acc. to IEC/EN 61508
  • ATEX Certification: BASEEFA 13 ATEX 0080, CML 19 ATEX 4410 X
  • ATEX Marking: II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I, II 3G Ex ec IIC T4 Gc
  • IECEx Certification: IECEx BAS 13.0046, IECEx CML 19.0147X
  • IECEx Marking: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I, Ex ec IIC T4 Gc
  • UL Approval: Control drawing 116-0374 (cULus)
  • Electromagnetic Compatibility: Directive 2014/30/EU, EN 61326-1:2013, NE 21:2011
  • Protection Standards: IEC 60529:2001 (IP20), IEC 61010-1:2010
  • Input Standard: EN 60947-5-6:2000
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Pepperl+Fuchs 214240 KCD2-SOT-Ex1.LB Switch Amplifier

What power supply voltage does the device require for operation?

The module operates on a rated voltage range of 19 to 30 V DC via screw terminals or Power Rail.

Can output II be configured as a dedicated fault output?

Yes, setting DIP switch S2 configures the second passive transistor output to signal line fault indications.

What sensor types are compatible with the field input terminals?

The field input accepts standard NAMUR proximity sensors or dry contact switches located in hazardous areas.

How fast is the signal response time across the transistor outputs?

The passive transistor outputs feature a fast response time of less than or equal to 200 microseconds.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Micro Drive Specialist EMS Bets on Custom Engineering to Broaden Market Appeal

UK micro-drive specialist EMS is pairing Faulhaber high-torque gearheads and compact motion controllers with in-house custom engineering—aiming beyond catalog sales into tailored mechatronics.

Bringing Object-Oriented Thinking to PLC Programming

Copy-paste ladder does not scale. Object-oriented PLC techniques—user-defined structures and instructions—cut duplication, propagate fixes once, and keep large multi-device programs readable.

Why Process Safety Management Programs Fail Even When OSHA Boxes Are Checked

OSHA boxes checked is not the same as a living PSM system. Refinery history shows programs fail when procedures, training, contractors, and investigations drift from how the plant actually runs.

What Is SCADA? Supervisory Control Without Replacing the PLC

SCADA sits above PLCs and RTUs: it acquires field data, alarms operators, and issues supervisory commands across plants and remote assets—without replacing local deterministic control.

What Is a VFD? Variable Frequency Drives That Actually Move the Needle

A VFD turns fixed-frequency mains into controlled voltage and frequency so AC motors match real load—cutting pump and fan energy while tightening torque, soft-start, and braking behavior.

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.