ProSoft MVI56E-MNETCR Modbus TCP/IP Multi-Client Enhanced Communication Module for Remote Chassis

Quantity

Product Description

The MVI56E-MNETCR is a Modbus TCP/IP Multi-Client Enhanced Communication Module for Remote Chassis that allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface with multiple Modbus TCP/IP server-compatible instruments and devices. This communication module improves network data transfer performance when controlling multiple servers on a Modbus TCP/IP network by supporting up to 30 clients. Operating as a single-slot module on the 1756 ControlLogix backplane, the MVI56E-MNETCR uses a small I/O data image for data transfer between the module and the ControlLogix processor, making it suitable for ControlNet or Ethernet remote rack installations.

Features

  • Supports up to 30 Clients with up to 16 commands for each client to enable multi-server connectivity
  • Integrated with RSLogix 5000 version 16 or higher using a supplied Add-On Instruction (AOI) or ladder file
  • Programmatically enables and disables commands easily from ladder logic to support multiple applications or recipes without reconfiguring the module
  • Remotely configures and diagnoses problems through remote racks using EtherNet/IP or ControlNet via interface modules without requiring RSLinx OEM software
  • Built-in web server provides web-enabled Ethernet port access to on-board documentation, module status, and firmware updates
  • Backward compatible with previous MVI56-MNETC applications by supporting existing ladder logic and configurations

Applications

  • Distributed ControlLogix remote chassis architectures
  • ControlNet or Ethernet remote rack communication networks
  • Industrial multi-server server-client bridging applications
  • SCADA and infrastructure remote monitoring networks

Technical Specifications

Specification Description
Manufacturer ProSoft
Product No. MVI56E-MNETCR
Product Type Modbus TCP/IP Multi-Client Enhanced Communication Module for Remote Chassis
Backplane Current Load 800 mA @ 5 V DC, 3 mA @ 24V DC
Operating Temperature 0 to 60 degC (32 to 140 Fahrenheit)
Storage Temperature -40 to 85 degC (-40 to 185 Fahrenheit)
Shock 30g Operational, 50g non-operational
Vibration 5 g from 10 to 150 Hz
Relative Humidity 5% to 95% (non-condensing)
LED Indicators Battery Status (ERR), Application Status (APP), Module Status (OK)
4-Character LED Display Scrolling, Alpha-numeric, shows Module, Version, IP, Application Port Setting, Port Status, and Error Information
Ethernet Port 10/100 Base-T, RJ45 Connector, for CAT5 cable, Link and Activity LED indicators, Auto-crossover cable detection
Shipped with Unit 5-foot Ethernet straight-through cable
Shipping Weight 2 Kg
Memory Capacity User-definable module data memory mapping of up to 5000, 16-bit registers
Modbus Function Codes Supported 1, 2, 3, 4, 5, 6, 7, 15, and 16
Configuration Tool ProSoft Configuration Builder (PCB)

Installation Guidelines

  • Module Placement: After checking the placement of the jumpers, insert the module into the single-slot 1756 ControlLogix chassis. Use the standard technique recommended by Rockwell Automation to remove and install modules.
  • Backplane Power Precaution: When inserting or removing the module while backplane power is on, an electrical arc can occur. Ensure power is removed or the area is known to be non-hazardous before proceeding to avoid contact wear or unintended motion.
  • Jumper Configuration: The Setup Jumper acts as write protection for the module flash memory. In write-protected mode, the Setup pins are not connected. If installing in a remote rack, leaving the Setup pins jumpered allows firmware updates without physical access but leaves the module open to unexpected updates.
  • Security Segmentation: Align with IEC 62443-1-1 and implement system segmentation (firewalls, DMZ, or unidirectional communication) to control data flow for security reasons.
  • Firmware and Logic: Before operation, import the required MVI56EMNETCR_AddOn_Rung_vXXX.L5X file containing the Add-On Instruction, user-defined data types, controller tags, and ladder logic into RSLogix 5000.

Compliance and Certifications

  • ANSI / ISA 12.12.01 Class I Division 2, GPs A, B, C, D
  • CSA/cUL C22.2 No. 213-M1987
  • CSA CB Certified IEC61010
  • ATEX EN60079-0 Category 3, Zone 2
  • ATEX EN60079-15
  • CE
  • UL/cUL
  • RoHS
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
How many clients can the module support simultaneously?
The module can support up to 30 clients with up to 16 commands allocated for each client to control multiple server devices on the network.
What software tool is used to configure this device?
The device is configured using the ProSoft Configuration Builder (PCB) software, which provides a graphical user interface for simple product and network setup.
What type of cable interface is used for the Ethernet configuration port?
The device features a 10/100 Base-T RJ45 connector designed for standard CAT5 cables, featuring auto-crossover cable detection and status LEDs.
Reviews

MVI56E-MNETCR

Stock & lead time on request

Call
1 of 1

ProSoft MVI56E-MNETCR Modbus TCP/IP Multi-Client Enhanced Communication Module for Remote Chassis

Only 10 item(s) left in stock
  • Manufacturer: ProSoft

  • Product No.: MVI56E-MNETCR

  • Country of origin:United States

  • Product Type: Communication Module

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The MVI56E-MNETCR is a Modbus TCP/IP Multi-Client Enhanced Communication Module for Remote Chassis that allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface with multiple Modbus TCP/IP server-compatible instruments and devices. This communication module improves network data transfer performance when controlling multiple servers on a Modbus TCP/IP network by supporting up to 30 clients. Operating as a single-slot module on the 1756 ControlLogix backplane, the MVI56E-MNETCR uses a small I/O data image for data transfer between the module and the ControlLogix processor, making it suitable for ControlNet or Ethernet remote rack installations.

Features

  • Supports up to 30 Clients with up to 16 commands for each client to enable multi-server connectivity
  • Integrated with RSLogix 5000 version 16 or higher using a supplied Add-On Instruction (AOI) or ladder file
  • Programmatically enables and disables commands easily from ladder logic to support multiple applications or recipes without reconfiguring the module
  • Remotely configures and diagnoses problems through remote racks using EtherNet/IP or ControlNet via interface modules without requiring RSLinx OEM software
  • Built-in web server provides web-enabled Ethernet port access to on-board documentation, module status, and firmware updates
  • Backward compatible with previous MVI56-MNETC applications by supporting existing ladder logic and configurations

Applications

  • Distributed ControlLogix remote chassis architectures
  • ControlNet or Ethernet remote rack communication networks
  • Industrial multi-server server-client bridging applications
  • SCADA and infrastructure remote monitoring networks

Technical Specifications

Specification Description
Manufacturer ProSoft
Product No. MVI56E-MNETCR
Product Type Modbus TCP/IP Multi-Client Enhanced Communication Module for Remote Chassis
Backplane Current Load 800 mA @ 5 V DC, 3 mA @ 24V DC
Operating Temperature 0 to 60 degC (32 to 140 Fahrenheit)
Storage Temperature -40 to 85 degC (-40 to 185 Fahrenheit)
Shock 30g Operational, 50g non-operational
Vibration 5 g from 10 to 150 Hz
Relative Humidity 5% to 95% (non-condensing)
LED Indicators Battery Status (ERR), Application Status (APP), Module Status (OK)
4-Character LED Display Scrolling, Alpha-numeric, shows Module, Version, IP, Application Port Setting, Port Status, and Error Information
Ethernet Port 10/100 Base-T, RJ45 Connector, for CAT5 cable, Link and Activity LED indicators, Auto-crossover cable detection
Shipped with Unit 5-foot Ethernet straight-through cable
Shipping Weight 2 Kg
Memory Capacity User-definable module data memory mapping of up to 5000, 16-bit registers
Modbus Function Codes Supported 1, 2, 3, 4, 5, 6, 7, 15, and 16
Configuration Tool ProSoft Configuration Builder (PCB)

Installation Guidelines

  • Module Placement: After checking the placement of the jumpers, insert the module into the single-slot 1756 ControlLogix chassis. Use the standard technique recommended by Rockwell Automation to remove and install modules.
  • Backplane Power Precaution: When inserting or removing the module while backplane power is on, an electrical arc can occur. Ensure power is removed or the area is known to be non-hazardous before proceeding to avoid contact wear or unintended motion.
  • Jumper Configuration: The Setup Jumper acts as write protection for the module flash memory. In write-protected mode, the Setup pins are not connected. If installing in a remote rack, leaving the Setup pins jumpered allows firmware updates without physical access but leaves the module open to unexpected updates.
  • Security Segmentation: Align with IEC 62443-1-1 and implement system segmentation (firewalls, DMZ, or unidirectional communication) to control data flow for security reasons.
  • Firmware and Logic: Before operation, import the required MVI56EMNETCR_AddOn_Rung_vXXX.L5X file containing the Add-On Instruction, user-defined data types, controller tags, and ladder logic into RSLogix 5000.

Compliance and Certifications

  • ANSI / ISA 12.12.01 Class I Division 2, GPs A, B, C, D
  • CSA/cUL C22.2 No. 213-M1987
  • CSA CB Certified IEC61010
  • ATEX EN60079-0 Category 3, Zone 2
  • ATEX EN60079-15
  • CE
  • UL/cUL
  • RoHS

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ProSoft MVI56E-MNETCR Modbus TCP/IP Multi-Client Enhanced Communication Module for Remote Chassis

How many clients can the module support simultaneously?

The module can support up to 30 clients with up to 16 commands allocated for each client to control multiple server devices on the network.

What software tool is used to configure this device?

The device is configured using the ProSoft Configuration Builder (PCB) software, which provides a graphical user interface for simple product and network setup.

What type of cable interface is used for the Ethernet configuration port?

The device features a 10/100 Base-T RJ45 connector designed for standard CAT5 cables, featuring auto-crossover cable detection and status LEDs.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...