1 of 1

Schneider Altistart 48 ATS48C32Y Soft Starter

Schneider Altistart 48 ATS48C32Y Soft Starter

Only 7 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: ATS48C32Y

  • Country of origin:France

  • Product Type: Soft starters

  • Payment: T/T, Western Union

  • Weight: 20000g

  • Dimensions: 51cm x 46cm x 43cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The ATS48C32Y is a Schneider Electric Altistart 48 soft starter engineered for the controlled acceleration and deceleration of asynchronous motors. Capable of handling a rated current of 302 A, this unit operates across a wide voltage range of 208-690 V and supports motor power ratings between 75 kW and 315 kW. By managing the torque and current during the motor start-up sequence, the ATS48C32Y effectively mitigates mechanical stress on drive trains and reduces voltage dips on the power supply network, enhancing the overall reliability of industrial motor-driven systems.

Features

  • Compatible with 3-phase asynchronous motors
  • Rated operational current: 302 A
  • Wide supply voltage range: 208-690 V
  • Power range coverage: 75-315 kW
  • Advanced motor protection and diagnostic monitoring
  • Smooth torque control for reduced mechanical wear

Applications

  • Pumping stations
  • Large-scale ventilation and fan systems
  • Industrial compressor units
  • Centrifugal machinery
  • Conveyor and material handling systems

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range Altistart 48
Product Type Soft starter
Rated Current 302 A
Operating Voltage 208-690 V
Power Rating 75-315 kW
Dimensions 51 x 46 x 43 cm
Weight 20.00 kg
Product Status Active
Commodity Code 84798997

Installation Guidelines

  • Mounting: Install the soft starter in a vertical position. Ensure the surrounding environment is free from conductive dust and corrosive gases.
  • Cooling: Maintain sufficient air clearance above and below the device to allow for natural convection. Do not obstruct the internal cooling channels.
  • Wiring: Connect the power input and output terminals according to the phase sequence. Use cables appropriately sized for a 302 A load.
  • Grounding: Secure a solid protective earth connection to the chassis to ensure operator safety and EMC compliance.
  • Environment: Ensure the installation site remains within the specified ambient temperature limits to prevent premature derating or thermal shutdown.
Loading product navigation…

What is the primary function of the ATS48C32Y?

The ATS48C32Y is a soft starter used to manage the start-up and stop sequences of 3-phase asynchronous motors, preventing high-torque transients and electrical surges.

What are the motor power and voltage limits for this unit?

This model supports motor power ratings from 75 kW to 315 kW and operates within a voltage range of 208V to 690V.

What is the rated operational current for the ATS48C32Y?

The device is rated for a continuous operational current of 302 A.

What installation factors are critical for this soft starter?

The unit must be mounted vertically with adequate clearance for cooling airflow to ensure proper heat dissipation and reliable operation.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
France
Power source
AC-powered

Recently Viewed Products

Technical knowledge

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...