The ATSU01N212LT is a compact Soft Starter from the Altistart U01 range, engineered for the smooth starting and stopping of three-phase asynchronous motors. By regulating the voltage ramp, this device effectively mitigates torque transients and high inrush currents, protecting mechanical components such as belts, chains, and gearboxes. It is designed for motors with a power rating between 2.2 kW and 5.5 kW, operating within a wide voltage supply range of 200V to 480V and a rated operational current of 12 A. Its ultra-compact design is specifically optimized for space-constrained control panels in various industrial sectors.
Features
Voltage ramp regulation for smooth motor acceleration
Integrated bypass contactor to optimize thermal performance
Ultra-compact form factor for high-density DIN rail mounting
Easy-to-adjust starting time and deceleration settings
Simplifies motor control for three-phase asynchronous machines
Applications
Small conveyors and material handling systems
Centrifugal and axial fans
Pumps and fluid processing equipment
Packaging and labeling machinery
Light-duty industrial automation tasks
Technical Specifications
Feature
Specification
Manufacturer
Schneider Electric
Range
Altistart
Subrange
U01
Model
ATSU01N212LT
Rated Operational Current
12 A
Supply Voltage
200-480 V
Motor Power Rating
2.2-5.5 kW
Commodity Code
84798997
Product Phase
Active
Weight
0.45 kg
Dimensions (H x W x D)
15 x 17.5 x 5.5 cm
Installation Guidelines
Mounting: Designed for standard DIN rail installation. Maintain a vertical orientation to ensure proper heat dissipation.
Ventilation: Ensure sufficient space around the unit to allow for natural convection; do not obstruct the housing vents.
Wiring: Verify motor and power supply connections match the required terminal designations. Use appropriate wire gauges to handle the 12 A nominal current.
Grounding: Secure a reliable chassis ground to the system earth to maintain electrical safety and EMC integrity.
Adjustment: Use the front-mounted potentiometers to fine-tune the acceleration/deceleration ramp according to the specific load requirements of the motor.
FAQ
What is the rated operational current for the ATSU01N212LT?
The rated operational current is 12 A.
Does this soft starter include a bypass contactor?
Yes, it features an integrated bypass contactor to reduce internal heat dissipation during steady-state operation.
What is the power range supported by this device?
It supports motors with power ratings between 2.2 kW and 5.5 kW.
Is this unit suitable for DIN rail mounting?
Yes, the ATSU01N212LT is specifically designed for standard DIN rail installation.