The ATV212WU75N4C is a variable frequency drive from the Altivar 212 series, specifically engineered for HVAC applications. This 7.5 kW drive operates on a 480 V three-phase power supply, providing efficient motor control for pumps, fans, and compressor systems. Built with an IP55 enclosure rating and EMC class C1 compliance, it is designed for demanding industrial and commercial environments where protection against dust and water jets is required.
Features
Altivar 212 series optimized for HVAC control
Power rating of 7.5 kW
Three-phase input voltage of 480 V
IP55 protection rating for reliable performance in harsh environments
Integrated EMC class C1 filter for reduced electromagnetic interference
Compact, robust design for versatile installation
Applications
HVAC system fan control
Centrifugal and circulation pump systems
Building management system (BMS) integration
Industrial process ventilation
Technical Specifications
Feature
Specification
Manufacturer
Schneider Electric
Range
Altivar
Subrange
212
Product Type
Variable frequency drives
Power Rating
7.5 kW
Voltage
480 V
Phases
3
Protection Rating
IP55
EMC Class
C1
Dimensions
36.00 x 41.50 x 27.00 cm
Weight
11.04 kg
Product Phase
Active
Commodity Code
85044095
Installation Guidelines
Ventilation: Ensure sufficient space around the drive to allow for adequate airflow and cooling.
Mounting: The ATV212WU75N4C must be mounted vertically on a flat, non-flammable surface.
Wiring: Use shielded cables for motor connections to maintain EMC class C1 compliance. Ensure all grounding connections are secure.
Environment: Protect the drive from direct sunlight, corrosive gases, and excessive vibration.
Cabling: Follow proper cable routing practices to separate power cables from control and communication signals to prevent interference.
FAQ
What is the primary application for the ATV212WU75N4C?
This drive is specifically designed for HVAC applications, including fan and pump control.
What protection level does this drive offer?
This unit features an IP55 protection rating, making it suitable for environments requiring protection against dust and water jets.
Is this drive compatible with standard three-phase power?
Yes, it is designed for a 480 V three-phase power supply.
What does the EMC class C1 rating signify?
The C1 rating indicates that the drive meets strict electromagnetic compatibility standards for use in public networks.
A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...
Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...
Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...
Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.
Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...
Seal-in circuits and OTL/OTU instructions can hold the same command, but they fail differently. This guide compares scan behavior, restart risk, troubleshooting, permissives, and safer PLC design...