The ATV212HD11M3X is a variable frequency drive (VFD) from the Altivar 212 series, specifically engineered for HVAC applications. Rated for 11 kW at 240 V, this frequency controller manages motor speed and torque with high efficiency to optimize energy consumption in pump, fan, and compressor systems. This unit is configured for 3-phase supply without an integrated EMC filter and is housed in an IP21-rated enclosure, providing reliable motor control for industrial and commercial building automation.

Features

  • 11 kW power rating for medium-duty motor applications.
  • Optimized specifically for HVAC-related drive functions.
  • IP21 enclosure rating for protection against solid objects.
  • 3-phase operation for balanced power distribution.
  • Robust control algorithms for energy-efficient motor management.

Applications

  • Centrifugal pumps and fan control.
  • HVAC system air handling units.
  • Cooling tower fan motor regulation.
  • Industrial process circulation systems.
  • Commercial building climate control integration.

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range Altivar
Subrange 212
Product Type Variable Frequency Drive
Power Rating 11 kW
Input Voltage 240 V
Phases 3
Enclosure Rating IP21
Weight 11.07 kg
Dimensions 39 x 29 x 28 cm
Commodity Code 85044095
Lifecycle Status Phase-Out

Installation Guidelines

  • Mounting: Install the ATV212HD11M3X in a vertical position within a ventilated cabinet to ensure proper heat dissipation.
  • Clearance: Maintain adequate spacing around the drive to allow for airflow, as specified in the official installation manual.
  • Wiring: Ensure power input and motor output cables are sized correctly for the 11 kW load; use shielded motor cables to mitigate potential electromagnetic noise.
  • Grounding: Connect the drive chassis to a solid earth ground point to ensure safety and operational stability.
  • Configuration: Perform initial parameter settings via the integrated keypad or communication interface to match motor nameplate data.

What is the power rating of the ATV212HD11M3X drive?

This drive has a power rating of 11 kW.

Is this drive equipped with an EMC filter?

No, this specific model (ATV212HD11M3X) is configured without an integrated EMC filter.

What is the primary application for the Altivar 212 series?

The Altivar 212 series is specifically designed and optimized for HVAC applications, including pumps, fans, and compressors.

What is the IP rating for this unit?

The drive is rated IP21.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France

Recently Viewed Products

Technical knowledge

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...