The BMXDRA0805H is a Discrete Output Module from the Modicon X80 range, specifically designed for use in harsh industrial environments. This module provides 8 relay outputs, each rated for 3 A, and is engineered for seamless integration with the Modicon M340 automation platform. It ensures robust control and reliable switching capabilities for demanding applications where environmental factors necessitate high durability.

Features

  • Module Type: Discrete output module
  • Outputs: 8 relay outputs
  • Output Rating: 3 A per output
  • Environmental Compatibility: Designed for harsh conditions
  • Range: Modicon X80 (compatible with Modicon M340)

Applications

  • Harsh environment process control
  • Industrial machine automation
  • Relay-based switching for electrical loads
  • Manufacturing process monitoring

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range Modicon X80
Product Type Digital modules
Number of Outputs 8
Output Type Relay
Rated Current 3 A
Dimensions 12.0 x 11.0 x 5.5 cm
Weight 0.19 kg
Commodity Code 85389091
Product Phase Active

Installation Guidelines

  • Mounting: The module is designed for installation on a Modicon M340 PLC rack. Ensure the module is properly seated and the locking latch is engaged.
  • Wiring: Connect output loads to the terminals according to the wiring diagram in the product manual. Verify that the load current does not exceed the 3 A relay rating.
  • Environmental: While designed for harsh conditions, ensure the module is housed within a suitable industrial enclosure to protect against direct moisture or chemical ingress.
  • Grounding: Maintain proper grounding of the PLC rack to ensure reliable operation and compliance with electromagnetic compatibility standards.
  • Maintenance: Regularly inspect terminal connections and ensure the module remains free of excessive debris or conductive dust.

FAQ

How many outputs does the BMXDRA0805H provide?

This module provides 8 relay outputs.

What is the rated current for each output?

Each relay output is rated for 3 A.

Is this module suitable for harsh environments?

Yes, it is specifically designed for reliable operation in harsh industrial conditions.

What is the product lifecycle status of this module?

This module is currently in the Active phase of its product lifecycle.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France
Power source
DC Power

Technical knowledge

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.