Description

The Schneider Electric ABE7P16T230 is a sub-base with 16 relay outputs designed for the Advantys Telefast connection system. This accessory facilitates the rapid and reliable connection of I/O modules to field devices, simplifying wiring in industrial automation architectures. The module provides a compact interface for managing discrete output signals, ensuring organized and efficient signal distribution in control cabinets.

Features

  • 16-channel relay output interface
  • Designed for integration with Advantys Telefast connection systems
  • Compact form factor for streamlined panel wiring
  • Robust terminal interface for industrial connectivity

Applications

  • PLC I/O signal distribution
  • Industrial machine control wiring
  • Distributed automation control panels
  • Signal interfacing between controllers and field devices

Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Brand Schneider Electric
Range Advantys Telefast
Product Type Accessories
Output Type 16 Relay Outputs
Product Phase Active
Dimensions (cm) 22 x 9.5 x 8
Weight 0.63 kg
Commodity Code 85369085

Installation Guidelines

  • Mounting: Secure the module to a standard DIN rail within the control enclosure.
  • Wiring: Use appropriate wire gauges for terminal connections to ensure secure signal transmission.
  • Labeling: Utilize the provided marking areas to label field connections for easier maintenance and troubleshooting.
  • Environment: Ensure the installation area is protected from extreme humidity and metallic dust to maintain relay performance.

FAQ

What is the primary function of the ABE7P16T230?

The ABE7P16T230 serves as a sub-base with 16 relay outputs for the Advantys Telefast system, used for connecting PLC I/O to field devices.

How many outputs does this module provide?

This module provides 16 relay output channels.

Is this product currently active?

Yes, the ABE7P16T230 is currently in the active phase of its product lifecycle.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 2
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
France
Power source
AC-powered

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.