Schneider Electric

Schneider Electric ATS48C14Y Altistart 48 Soft Starters

SKU ATS48C14Y

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Schneider Electric

  • Product No.: ATS48C14Y

  • Country of origin:France

  • Product Type: Soft starters

  • Payment: T/T, Western Union

  • Weight: 14890g

  • Dimensions: 46cm x 43cm x 34cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The ATS48C14Y is an Altistart 48 soft starter engineered by Schneider Electric for asynchronous motors with a rated current of 124 A. This industrial device provides torque control for smooth, controlled starting and stopping of motors, significantly reducing mechanical stress and wear on equipment. Operating across a voltage range of 208-690V and supporting power ratings from 30-110 kW, the ATS48C14Y delivers reliable performance and enhanced operational longevity in intensive industrial automation settings.

Features

  • Designed for asynchronous motors with a 124 A capacity
  • Supports a voltage range of 208-690V and power ratings between 30-110 kW
  • Torque control system for smooth startup and shutdown phases
  • Minimizes mechanical stress on connected machinery and transmission systems

Applications

  • Industrial pumps and fluid transfer systems
  • Heavy-duty fans and ventilation units
  • Compressors and industrial machinery
  • Conveyor belts and material handling systems

Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Range Altistart
Subrange 48
Type of product Soft starters
Product phase Phase-Out
Dimensions 46 x 43 x 34 cm
Weight 14.89 kg
Commodity Code 84798997
Export Control Regulations (ECCN) N

Installation Guidelines

  • Ensure proper vertical panel mounting with adequate clearance above and below the unit for airflow and thermal dissipation.
  • Follow standard industrial grounding protocols to ensure electrical safety and mitigate electromagnetic disturbances.
  • Keep power cables separated from control and communication wiring to maintain signal integrity.

FAQ

What is the rated current capacity of the ATS48C14Y soft starter?

The rated current capacity is 124 A.

What power and voltage ranges does this soft starter support?

It supports a voltage range of 208-690V and power ratings between 30-110 kW.

What is the total weight and dimension of the unit?

The unit weighs 14.89 kg with dimensions of 46 x 43 x 34 cm.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
France
Power source
AC-powered

Technical knowledge

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.

Grounded or Floating 24 VDC? A Control-Panel Decision Guide

Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...

Seal-In Logic or OTL/OTU? Choosing PLC Memory Safely

Seal-in circuits and OTL/OTU instructions can hold the same command, but they fail differently. This guide compares scan behavior, restart risk, troubleshooting, permissives, and safer PLC design...