The LC1D95P7 is a TeSys D series Contactor, designed for high-performance switching in power and motor control applications. Engineered for reliability, this contactor is rated for 95 A (AC-3 duty) at voltages up to 440 V, making it suitable for demanding industrial motor control requirements. It features a control coil voltage of 230 V AC and is built for consistent performance in various operational environments.

Features

  • Range: TeSys D
  • Type: Contactor
  • Rated Operational Current: 95 A (AC-3, up to 440 V)
  • Control Circuit Voltage: 230 V AC
  • Robust design for industrial switching applications
  • Reliable performance for motor control and power distribution

Applications

  • Industrial motor starting and control
  • Heating, ventilation, and air conditioning (HVAC) systems
  • Power distribution and circuit switching
  • Automated production machinery

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range TeSys D
Product Type Contactors
Rated Current 95 A
Control Voltage 230 V AC
Dimensions 14 x 13.5 x 9.5 cm
Weight 1.57 kg
Commodity Code 85364900
Product Phase Active

Installation Guidelines

  • Mounting: Designed for mounting on a 35 mm DIN rail or panel mounting. Ensure the mounting surface is stable and level.
  • Wiring: Connect line and load conductors to the power terminals. Use correctly sized conductors and tighten terminal screws to the manufacturer’s specified torque to ensure reliable contact.
  • Control Wiring: Connect the 230 V AC control circuit to the coil terminals (A1/A2). Verify the control voltage matches the coil rating before energizing.
  • Environment: Install within an appropriate enclosure to protect the contactor from moisture, conductive dust, and extreme temperatures.
  • Maintenance: Periodically check terminal tightness and inspect for signs of contact erosion or debris accumulation during routine inspections.

FAQ

What is the rated operational current of the LC1D95P7?

This contactor has a rated operational current of 95 A (AC-3, up to 440 V).

What is the control voltage for this model?

The control circuit coil voltage is 230 V AC.

What is the current status of the TeSys D product line?

This product is currently in the Active phase of its product lifecycle.

What is the weight of the LC1D95P7 contactor?

The unit weighs 1.57 kg.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 9 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
France

Technical knowledge

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...

Interposing Relays: Isolation, Load Matching, and Diagnostics

Interposing relays protect PLC and DCS interfaces by separating voltage domains, matching output capacity to field loads, and making faults easier to isolate. This guide explains selection,...