Schneider Electric

Schneider Electric LXD1E7 TeSys D Contactor Coil

SKU LXD1E7

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Schneider Electric
  • Product No.: LXD1E7
  • Origin France
  • Product Type: Contactor Coils
  • Payment: T/T, Western Union
  • Weight: 0.08 kg
  • Dimensions: 4cm x 6,3cm x 4,4cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The LXD1E7 is a replacement 48V AC control coil designed for the TeSys D series contactors, specifically compatible with LC1D09-38 and T20-T40 models. This component serves as the electromagnetic actuator for the contactor, ensuring precise and reliable switching operations within industrial electrical distribution systems. Manufactured for high durability, the LXD1E7 provides consistent performance in demanding control circuit applications.

Features

  • Compatibility: Designed for TeSys LC1D09 through LC1D38 contactors
  • Control Voltage: 48V AC
  • Series: TeSys D
  • Reliable Actuation: Optimized for standard industrial switching cycles

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Brand Schneider Electric
Series Tesys D
Model LXD1E7
Control Voltage 48V AC
Dimensions (LxWxH) 4 cm x 6.3 cm x 4.4 cm
Weight 0.08 kg
Commodity Code 85366990
Product Phase Active
Country of Origin France

Installation Guidelines

  • Safety: Ensure the control circuit is de-energized and locked out before attempting to replace the coil.
  • Compatibility: Verify that the contactor base unit is within the compatible LC1D09-38 range before installation.
  • Replacement: Access the contactor housing according to the manufacturer's maintenance manual, remove the existing coil, and slide the LXD1E7 into position, ensuring proper seating of the magnetic core.
  • Wiring: Connect the control voltage leads to the coil terminals, ensuring tight, secure connections to prevent contact resistance.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
Which contactors are compatible with the LXD1E7 coil?
The LXD1E7 is compatible with TeSys LC1D09-38 and T20-T40 series contactors.
What is the control voltage rating for this coil?
This coil is rated for 48V AC operation.
Is this a standard replacement part?
Yes, it is a standard active replacement coil for the TeSys D series contactor range.
Reviews

LXD1E7

Stock & lead time on request

Call
1 of 1

Schneider Electric LXD1E7 TeSys D Contactor Coil

Only 8 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: LXD1E7

  • Country of origin:France

  • Product Type: Contactor Coils

  • Payment: T/T, Western Union

  • Weight: 80g

  • Dimensions: 4cm x 6,3cm x 4,4cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The LXD1E7 is a replacement 48V AC control coil designed for the TeSys D series contactors, specifically compatible with LC1D09-38 and T20-T40 models. This component serves as the electromagnetic actuator for the contactor, ensuring precise and reliable switching operations within industrial electrical distribution systems. Manufactured for high durability, the LXD1E7 provides consistent performance in demanding control circuit applications.

Features

  • Compatibility: Designed for TeSys LC1D09 through LC1D38 contactors
  • Control Voltage: 48V AC
  • Series: TeSys D
  • Reliable Actuation: Optimized for standard industrial switching cycles

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Brand Schneider Electric
Series Tesys D
Model LXD1E7
Control Voltage 48V AC
Dimensions (LxWxH) 4 cm x 6.3 cm x 4.4 cm
Weight 0.08 kg
Commodity Code 85366990
Product Phase Active
Country of Origin France

Installation Guidelines

  • Safety: Ensure the control circuit is de-energized and locked out before attempting to replace the coil.
  • Compatibility: Verify that the contactor base unit is within the compatible LC1D09-38 range before installation.
  • Replacement: Access the contactor housing according to the manufacturer's maintenance manual, remove the existing coil, and slide the LXD1E7 into position, ensuring proper seating of the magnetic core.
  • Wiring: Connect the control voltage leads to the coil terminals, ensuring tight, secure connections to prevent contact resistance.
Key Features:

Which contactors are compatible with the LXD1E7 coil?

The LXD1E7 is compatible with TeSys LC1D09-38 and T20-T40 series contactors.

What is the control voltage rating for this coil?

This coil is rated for 48V AC operation.

Is this a standard replacement part?

Yes, it is a standard active replacement coil for the TeSys D series contactor range.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
France

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...