Schneider Electric

Schneider Electric TM258LF42DR Modicon M258 Logic Controller

SKU TM258LF42DR

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Schneider Electric

  • Product No.: TM258LF42DR

  • Country of origin:France

  • Product Type: Logic Controllers

  • Payment: T/T, Western Union

  • Weight: 1040g

  • Dimensions: 37.0 cm x 15.0 cm x 13.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed to meet high-performance requirements in industrial machine automation, the Schneider Electric TM258LF42DR serves as a robust controller base unit within the Modicon M258 platform. This compact programmable logic controller (PLC) integrates 42 diverse inputs and outputs (I/O) with built-in relay functionality, making it highly adaptable for complex control architectures. Operating on a 24V DC power supply, the controller features native communication interfaces including an integrated CANopen port to facilitate reliable, high-speed data exchange with drives, remote I/O modules, and external field devices. Its space-saving design ensures seamless installation into standard control panels without sacrificing processing power or connection density.

Features

  • High-density integration containing 42 onboard inputs and outputs.
  • Built-in relay outputs alongside fast transistor channels for versatile load handling.
  • Integrated CANopen master/slave port for flexible fieldbus system design.
  • Robust 24V DC industrial power supply compatibility.
  • Fully compatible with EcoStruxure Machine Expert (SoMachine) programming environments.

Applications

  • Packaging, sorting, and materials handling machinery.
  • Pumping, municipal water, and wastewater treatment processes.
  • Conveyor systems and industrial hoisting equipment.
  • HVAC, climate control, and environmental chamber management.
  • OEM machine building and general factory automation lines.

Technical Specifications

Manufacturer Schneider Electric
Part Number / Model TM258LF42DR
Product Series Modicon M258
Product Type Logic Controller Base Unit
Total Integrated I/O 42 I/O
Rated Supply Voltage 24V DC
Output Type Relay and Transistor
Communication Interface CANopen, Serial Link, Ethernet
Product Status Active
Dimensions 37.0 cm x 15.0 cm x 13.0 cm
Weight 1.04 kg

Installation Guidelines

For safe installation and long-term operating reliability, adhere to the following standard engineering procedures:

  • Mounting: Mount the controller on a standard 35mm symmetrical DIN rail inside a protective, dust-free enclosure rated for the local environment.
  • Grounding: Connect the functional ground (FE) terminal directly to the panel backplane using a heavy-gauge, low-impedance copper wire.
  • Thermal Management: Maintain a minimum spacing clearance of 50mm above and below the module to allow for natural convection cooling.
  • Wiring: Always de-energize the 24V DC power supply and field circuit relay voltages before inserting or removing wire terminals to prevent transient voltage damage.

Compliance and Certifications

  • CE Compliant
  • UL Listed
  • CSA Certified

FAQ

What is the primary power requirement for the TM258LF42DR?

The TM258LF42DR logic controller operates on a nominal supply voltage of 24V DC.

Does the TM258LF42DR have built-in communication ports?

Yes, this controller features an integrated CANopen communication interface, alongside support for standard Ethernet and serial links.

What is the I/O configuration of this Modicon M258 base unit?

The module contains 42 built-in inputs and outputs, which include a mix of transistor digital channels and integrated relay outputs.

Which programming software is used to configure the TM258LF42DR?

It is configured and programmed using Schneider Electric's EcoStruxure Machine Expert (previously known as SoMachine) software environment.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
France

Technical knowledge

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.