The Schneider Electric GV2ME16 is a TeSys GV2ME thermal-magnetic circuit breaker designed to protect industrial electrical systems and motor loads. Operating within a current range of 9 to 14 A, this device integrates both thermal overload protection and magnetic short-circuit protection to ensure reliable equipment safety. Equipped with convenient screw clamp terminals for secure wire termination, the compact unit measures 9.2 x 8.5 x 4.7 cm and weighs 0.28 kg. It provides dependable performance and helps minimize system downtime in demanding industrial environments.

Features

  • Thermal-magnetic trip unit providing comprehensive overload and short-circuit protection
  • Adjustable or calibrated current setting range of 9 to 14 A for precise motor protection
  • Secure screw clamp terminal connections for reliable wiring integrity
  • Compact physical form factor with dimensions of 9.2 x 8.5 x 4.7 cm and a weight of 0.28 kg
  • Active lifecycle status within the Schneider Electric TeSys product range

Applications

  • Motor control and starter protection circuits
  • Industrial machinery and automated production lines
  • Control panel power distribution and safeguarding
  • HVAC and pumping station electrical systems

Technical Specifications

Specification Detail
Brand Schneider Electric
Manufacturer Schneider Electric
Range Tesys D
Type of Product Circuit breakers
Product Phase Active
Dimensions 9.2 x 8.5 x 4.7 cm
Weight 0.28 kg
Commodity Code 85362010
Export Control Regulations (ECCN) N

Connections/Interfaces

Terminal Type Connection Method
Power and Control Terminals Screw Clamp Terminals

Installation Guidelines

  • Disconnect all electrical power sources upstream before performing any installation or maintenance work.
  • Mount the circuit breaker securely onto standard 35 mm DIN rails or directly onto mounting plates inside the control enclosure.
  • Connect incoming and outgoing power cables to the screw clamp terminals, ensuring proper torque to avoid loose connections.
  • Verify correct wire gauge sizing and ensure proper stripping length for secure terminal seating.
  • Test the trip mechanism and verify proper system operation prior to energizing the circuit.
Loading product navigation…

What protection mechanism does the GV2ME16 circuit breaker use?

It uses a thermal-magnetic protection mechanism for overloads and short circuits.

What is the operational current range of this circuit breaker?

The current range is 9 to 14 A.

What are the dimensions and weight of the unit?

The dimensions are 9.2 x 8.5 x 4.7 cm and the weight is 0.28 kg.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...