The Schneider Electric GV2ME16 is a TeSys GV2ME thermal-magnetic circuit breaker designed to protect industrial electrical systems and motor loads. Operating within a current range of 9 to 14 A, this device integrates both thermal overload protection and magnetic short-circuit protection to ensure reliable equipment safety. Equipped with convenient screw clamp terminals for secure wire termination, the compact unit measures 9.2 x 8.5 x 4.7 cm and weighs 0.28 kg. It provides dependable performance and helps minimize system downtime in demanding industrial environments.

Features

  • Thermal-magnetic trip unit providing comprehensive overload and short-circuit protection
  • Adjustable or calibrated current setting range of 9 to 14 A for precise motor protection
  • Secure screw clamp terminal connections for reliable wiring integrity
  • Compact physical form factor with dimensions of 9.2 x 8.5 x 4.7 cm and a weight of 0.28 kg
  • Active lifecycle status within the Schneider Electric TeSys product range

Applications

  • Motor control and starter protection circuits
  • Industrial machinery and automated production lines
  • Control panel power distribution and safeguarding
  • HVAC and pumping station electrical systems

Technical Specifications

Specification Detail
Brand Schneider Electric
Manufacturer Schneider Electric
Range Tesys D
Type of Product Circuit breakers
Product Phase Active
Dimensions 9.2 x 8.5 x 4.7 cm
Weight 0.28 kg
Commodity Code 85362010
Export Control Regulations (ECCN) N

Connections/Interfaces

Terminal Type Connection Method
Power and Control Terminals Screw Clamp Terminals

Installation Guidelines

  • Disconnect all electrical power sources upstream before performing any installation or maintenance work.
  • Mount the circuit breaker securely onto standard 35 mm DIN rails or directly onto mounting plates inside the control enclosure.
  • Connect incoming and outgoing power cables to the screw clamp terminals, ensuring proper torque to avoid loose connections.
  • Verify correct wire gauge sizing and ensure proper stripping length for secure terminal seating.
  • Test the trip mechanism and verify proper system operation prior to energizing the circuit.

FAQ

What protection mechanism does the GV2ME16 circuit breaker use?

It uses a thermal-magnetic protection mechanism for overloads and short circuits.

What is the operational current range of this circuit breaker?

The current range is 9 to 14 A.

What are the dimensions and weight of the unit?

The dimensions are 9.2 x 8.5 x 4.7 cm and the weight is 0.28 kg.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 6
Only 9 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France

Technical knowledge

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.