Siemens

Siemens 6AV7414-2AB00-0KB0 SIMATIC IPC677C Panel PC

SKU 6AV7414-2AB00-0KB0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7414-2AB00-0KB0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 19g

  • Dimensions: 38.0 x 33.0 x 10.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7414-2AB00-0KB0 is a SIMATIC HMI IPC677C Panel PC featuring a 19-inch touchscreen interface. This unit is a customer-specific variant (Design B) engineered exclusively for Bobst Mex SA, based on the 6AV7894-0AD10-1AB2 hardware platform. Designed for continuous operation in demanding industrial environments, this Panel PC provides a robust and reliable human-machine interface for process control, visualization, and data acquisition tasks. Its specific configuration ensures seamless integration into designated automation systems.

Features

  • 19-inch touchscreen display for operator control and monitoring.
  • Customer-specific design for dedicated system integration.
  • Built for high reliability and continuous operation in industrial settings.
  • Part of the SIMATIC IPC677C series of industrial PCs.

Applications

  • Machine control and visualization (HMI).
  • Production data acquisition and logging.
  • Process monitoring in manufacturing facilities.
  • Integration into specialized OEM machinery.

Technical Specifications

Specification Value
Brand Siemens
Part Number 6AV7414-2AB00-0KB0
Product Line SIMATIC Panel PC
Series IPC677C
Product Type Panel PC
Display 19-inch Touchscreen
Design Basis Based on 6AV7894-0AD10-1AB2
Product Lifecycle Phase Obsolete
Shipping Weight 19.00 kg
Package Dimensions 38.0 x 33.0 x 10.0 cm
Harmonized Tariff Code 85371091
Export Control (ECCN) 5D992
Country of Origin Germany (Estimated)
Manufacturer Siemens

Installation Guidelines

CRITICAL WARNING: Installation and maintenance must be performed by qualified personnel only. Failure to de-energize equipment before installation can result in severe electrical shock, injury, or death. Always adhere to local and national safety regulations, including Lockout/Tagout (LOTO) procedures.
  1. 1
    De-energize System: Before beginning installation, completely disconnect and lock out all power sources to the control cabinet or mounting location. Verify the absence of voltage using a calibrated multimeter.
  2. 2
    Prepare Panel Cutout: Ensure the mounting cutout in the enclosure panel matches the required dimensions for the IPC677C chassis. Deburr all sharp edges to prevent damage to cables and ensure a proper seal.
  3. 3
    Mount the Unit: Insert the Panel PC into the cutout from the front of the enclosure. Secure it from the rear using the provided mounting clamps. Tighten the clamp screws evenly in a diagonal pattern to ensure uniform gasket compression and a proper IP rating seal.
  4. 4
    Connect Protective Earth (PE): Connect a low-impedance protective earth conductor to the designated PE terminal on the unit's chassis. This connection is critical for operator safety and electromagnetic compatibility (EMC).
  5. 5
    Connect Power and I/O: Connect the main power supply to the specified input terminals. Connect all required communication cables (e.g., Ethernet, PROFIBUS) and any other I/O wiring to their respective ports. Ensure all connectors are fully seated and secured.
  6. 6
    Final System Check: Before re-energizing the cabinet, verify all connections are correct and secure. Ensure proper cable management to prevent strain on connectors and interference with other components. Remove all tools and debris from the enclosure.

FAQ

What is the screen size of this Panel PC?

The 6AV7414-2AB00-0KB0 features a 19-inch touchscreen display for operator interaction and system visualization.

Is this a standard off-the-shelf product?

No, this is a customer-specific design (Design B) developed for Bobst Mex SA. It is based on the standard 6AV7894-0AD10-1AB2 platform but may have unique hardware or software configurations.

What is the product lifecycle status of this model?

According to the manufacturer's information, the 6AV7414-2AB00-0KB0 is classified as an obsolete product.

What are the shipping dimensions and weight?

The package dimensions are 38.0 x 33.0 x 10.0 cm, and the shipping weight is 19.00 kg.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.