Siemens

Siemens 6AV7611-0AA10-0BE0 SIMATIC Panel PC 670

SKU 6AV7611-0AA10-0BE0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7611-0AA10-0BE0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 35.00 x 25.00 x 25.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is a Siemens 6AV7611-0AA10-0BE0 SIMATIC Panel PC 670, an integrated operator panel and industrial computer designed for machine-level control and visualization. This standard configuration unit features a 10-inch TFT display, a Celeron 300 MHz CPU, 64 MB of RAM, and a 20 GB hard drive. It is configured for a 115-230V AC power supply and includes a U.S. mains cable. The pre-installed operating system is Windows 98 in German. Please note that this product is considered obsolete by the manufacturer, making it suitable for legacy system maintenance and spare parts inventory.

Features

  • Integrated 10-inch TFT color display for operator visualization.
  • Powered by a Celeron 300 MHz processor.
  • Equipped with 64 MB of RAM and a 20 GB hard disk drive.
  • Flexible power input range of 115-230V AC.
  • Pre-loaded with Windows 98 operating system (German language version).
  • Robust industrial design for panel mounting.

Applications

  • Human-Machine Interface (HMI) for process control.
  • SCADA node for data acquisition and supervision.
  • Machine control and data logging applications.
  • Replacement unit for existing SIMATIC PC 670 installations.
  • Test and measurement stations.

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC Panel PC 670
Display 10-inch TFT
Processor (CPU) Celeron 300 MHz
Memory (RAM) 64 MB
Storage 20 GB Hard Drive (HD)
Operating System Windows 98 (German)
Power Supply 115-230V AC
Included Cable U.S. Mains Cable
Product Lifecycle Status Obsolete
Shipping Weight 12.00 kg
Package Dimensions (Calculated) 35.00 x 25.00 x 25.00 cm
Country of Origin Germany (Estimated)
Harmonized Tariff Code 85371091
ECCN N

Installation Guidelines

CRITICAL WARNING: Electrical hazard. Installation must be performed by qualified personnel only. Ensure the control panel is completely de-energized and locked out/tagged out (LOTO) before beginning any installation, wiring, or maintenance procedures. Failure to do so can result in severe injury or death.
  1. 1
    Panel Preparation: Prepare the mounting cutout in the enclosure door or panel according to the device's mechanical drawings. Ensure the mounting surface is clean, flat, and free of debris to achieve a proper seal.
  2. 2
    Mounting: Insert the Panel PC into the cutout from the front of the panel. Secure it from the rear using the provided mounting clamps. Tighten the clamp screws evenly in a cross pattern to ensure uniform pressure on the gasket for a proper seal. Do not overtighten.
  3. 3
    Grounding: Connect the functional earth (FE) or protective earth (PE) terminal on the rear of the unit to the main grounding point of the control cabinet using a short, low-impedance conductor. A proper ground connection is essential for noise immunity and safety.
  4. 4
    Power Connection: Connect the 115-230V AC mains power using the provided cable to the designated power input terminal. Ensure the source voltage matches the device's rating. Use appropriate circuit protection (e.g., fuse or circuit breaker) as required by local electrical codes.
  5. 5
    Interface Wiring: Connect all required communication (e.g., Ethernet, serial) and I/O cables. Route cables to minimize interference from high-voltage power lines. Use shielded cables for communication links and ensure shields are properly terminated.

FAQ

What operating system is installed on the 6AV7611-0AA10-0BE0?

This unit comes pre-installed with Windows 98. Please note that the language version is German.

What is the screen size of this SIMATIC Panel PC?

The device is equipped with a 10-inch TFT display.

Is this a current product from Siemens?

No, the 6AV7611-0AA10-0BE0 is classified as an obsolete product by the manufacturer. It is primarily available for maintaining or replacing existing legacy systems.

What are the power supply requirements for this Panel PC?

This model operates on a 115-230V AC power supply. A U.S. mains cable is included with the unit.

What are the core processing specifications?

The Panel PC is configured with a Celeron 300 MHz CPU, 64 MB of RAM, and a 20 GB hard drive.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...