Description
The Siemens 6AV7611-0AA20-0BF0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This unit features a 10-inch TFT display and is configured with a Celeron 300 MHz processor, 128 MB of RAM, and a 20 GB hard drive. It operates on a 115-230 V AC power supply and comes pre-installed with the Windows 98 operating system in English. This model is noted as an obsolete product, making it suitable for maintaining or replacing components in legacy automation systems.
Features
- 10-inch color TFT display for clear process visualization.
- Celeron 300 MHz CPU for reliable performance in HMI tasks.
- Equipped with 128 MB RAM and a 20 GB hard disk drive.
- Pre-loaded with Windows 98 (English) operating system.
- Includes a U.S. mains cable for 115-230 V AC power connection.
- Robust construction for industrial environments.
Applications
- Machine-level operator control and monitoring.
- Data acquisition and logging systems.
- Process visualization in manufacturing and production lines.
- Replacement unit for existing SIMATIC PC 670 installations.
Technical Specifications
| Specification |
Value |
| Manufacturer |
Siemens |
| Part Number |
6AV7611-0AA20-0BF0 |
| Product Series |
SIMATIC Panel PC 670 |
| Product Type |
Panel PC |
| Display |
10-inch TFT |
| Processor (CPU) |
Celeron 300 MHz |
| Memory (RAM) |
128 MB |
| Storage |
20 GB Hard Drive (HD) |
| Operating System |
Windows 98 (English) |
| Input Voltage |
115-230 V AC (via included U.S. mains cable) |
| Product Lifecycle Status |
Obsolete |
| Shipping Weight |
4.00 kg |
| Commodity Code |
85371091 |
| Export Control (ECCN) |
N |
| Country of Origin |
Germany (Estimated) |
| Package Dimensions (Calculated) |
40 x 30 x 15 cm (Estimated) |
Installation Guidelines
CRITICAL WARNING: Electrical Hazard. Disconnect and lock out all power sources before installation or servicing. Installation must be performed by qualified personnel familiar with industrial control panel standards and practices. Failure to comply can result in severe injury or equipment damage.
-
1
Prepare Enclosure: Verify that the panel cutout dimensions match the PC 670's mounting requirements. Ensure the mounting surface is clean, flat, and can support the unit's weight.
-
2
Mount Unit: Insert the Panel PC into the cutout from the front of the enclosure. Secure it from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's specified torque to ensure a proper seal.
-
3
Establish Ground Connection: Connect the chassis ground terminal on the Panel PC to the enclosure's protective earth (PE) bus bar using a low-impedance conductor. This is critical for both safety and noise immunity.
-
4
Connect Power: With the main power source de-energized, connect the supplied U.S. mains cable to the unit's power input socket and to a properly rated and protected 115-230 V AC source.
-
5
Connect Peripherals: Connect any required communication cables (e.g., Ethernet, serial) and I/O devices. Ensure proper cable routing and strain relief to prevent accidental disconnection. Power on the system only after all connections are secure and the enclosure is closed.