Siemens 6AV7611-0AB12-0AG0 SIMATIC Panel PC 670

SKU 6AV7611-0AB12-0AG0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7611-0AB12-0AG0

  • Country of origin:Germany

  • Product Type: PC Panel

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 35.00 x 25.00 x 25.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7611-0AB12-0AG0 is a SIMATIC Panel PC 670, designed for industrial human-machine interface (HMI) and control applications. This unit features a 10-inch TFT display and comes in a standard configuration including a 20 GB hard drive, a CD-ROM drive, and 64 MB of RAM. It is powered by a Pentium III 500 MHz CPU and operates on a 24 V DC power supply. The Panel PC is pre-installed with a multi-language version of Windows 2000, supporting English, German, French, Italian, and Spanish. As part of the SIMATIC Panel PC 670 range, this product is currently in an obsolete product phase.

Features

  • 10-inch TFT Display
  • Pentium III 500 MHz CPU
  • 20 GB Hard Drive
  • Integrated CD-ROM Drive
  • 64 MB RAM
  • 24 V DC Power Supply
  • Pre-installed Windows 2000 Multi-Language (EN, GER, FR, IT, SP)
  • Designed for industrial environments

Applications

The Siemens SIMATIC Panel PC 670 is suitable for various industrial automation applications, including:

  • Human-Machine Interface (HMI) for machine and process control
  • Data acquisition and visualization systems
  • Supervisory control and monitoring in manufacturing plants
  • Embedded control solutions requiring a compact, integrated PC platform
  • Industrial workstation for plant floor operations

Technical Specifications

Brand Siemens
Manufacturer Siemens
Range SIMATIC Panel PC
Subrange PC670
Product Type PC Panel
Display Type TFT
Display Size 10 inches
Hard Drive Capacity 20 GB
Optical Drive CD-ROM
RAM 64 MB
CPU Pentium III 500 MHz
Power Supply 24 V DC
Operating System Windows 2000 Multi-Language (EN, GER, FR, IT, SP)
Product Phase Obsolete
Package Dimensions (Calculated) 35.00 x 25.00 x 25.00 cm
Shipping Weight 12.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. De-energize System: Ensure all power to the installation area and associated equipment is completely disconnected and locked out before beginning any work.
  2. Mounting: Securely mount the Panel PC into a suitable panel cutout or enclosure, ensuring adequate clearance for ventilation and cable routing.
  3. Power Connection: Connect the 24 V DC power supply to the designated terminals, observing correct polarity. Verify the power source meets the specified voltage and current requirements.
  4. Grounding: Establish a proper protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
  5. Peripheral Connections: Connect any necessary peripherals such as keyboards, mice, or external storage devices to the available ports.
  6. Cable Routing: Route all power, signal, and communication cables to prevent strain, interference, and damage. Use appropriate cable glands and conduits where necessary.
  7. Ventilation: Ensure that the installation environment provides sufficient airflow to prevent overheating, especially around the ventilation openings of the Panel PC.
  8. Power Up: After all connections are verified, re-energize the system and observe for proper startup and operation.

FAQ

What is the display size of the Siemens 6AV7611-0AB12-0AG0?

The Panel PC features a 10-inch TFT display.

What operating system is pre-installed on this Panel PC?

It comes with Windows 2000 Multi-Language pre-installed, supporting English, German, French, Italian, and Spanish.

What are the power supply requirements for the 6AV7611-0AB12-0AG0?

The unit requires a 24 V DC power supply.

Is the Siemens 6AV7611-0AB12-0AG0 still actively manufactured?

No, this product is currently in an obsolete product phase.

What is the CPU type and speed?

It is equipped with a Pentium III CPU running at 500 MHz.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.